Biodegradable Cable-Tie Rapamycin-eluting Stents

被引:0
|
作者
Cheng-Hung Lee
Ming-Jer Hsieh
Shang-Hung Chang
Chang-Lin Chiang
Ching-Lung Fan
Shih-Jung Liu
Wei-Jan Chen
Chao-Jan Wang
Ming-Yi Hsu
Kuo-Chun Hung
Chung-Chuan Chou
Po-Cheng Chang
机构
[1] Chang Gung University College of Medicine,Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital
[2] Chang Gung University,Linkou
[3] Chang Gung Memorial Hospital-Linkou,Department of Mechanical Engineering
[4] Chang Gung Memorial Hospital-Linkou,Department of Orthopedic Surgery
来源
Scientific Reports | / 7卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
“Cable-tie” type biodegradable stents with drug-eluting nanofiber were developed to treat rabbit denuded arteries in this study. Biodegradable stents were fabricated using poly-L-lactide film following being cut and rolled into a cable-tie type stent. Additionally, drug-eluting biodegradable nanofiber tubes were electrospun from a solution containing poly (lactic-co-glycolic acid), rapamycin, and hexafluoroisopropanol, and then mounted onto the stents. The fabricated rapamycin-eluting cable-tie stents exhibited excellent mechanical properties on evaluation of compression test and collapse pressure, and less than 8% weight loss following being immersed in phosphate-buffered saline for 16 weeks. Furthermore, the biodegradable stents delivered high rapamycin concentrations for over 4 weeks and achieved substantial reductions in intimal hyperplasia associated with elevated heme oxygenase-1 and calponin level on the denuded rabbit arteries during 6 months of follow-up. The drug-eluting cable-tie type stents developed in this study might have high potential impacts for the local drug delivery to treat various vascular diseases.
引用
收藏
相关论文
共 50 条
  • [1] Biodegradable Cable-Tie Rapamycin-eluting Stents
    Lee, Cheng-Hung
    Hsieh, Ming-Jer
    Chang, Shang-Hung
    Chiang, Chang-Lin
    Fan, Ching-Lung
    Liu, Shih-Jung
    Chen, Wei-Jan
    Wang, Chao-Jan
    Hsu, Ming-Yi
    Hung, Kuo-Chun
    Chou, Chung-Chuan
    Chang, Po-Cheng
    SCIENTIFIC REPORTS, 2017, 7
  • [2] Pharmacokinetics of rapamycin-eluting stents in miniswine coronary model
    Yu, MY
    Gao, RL
    Jiang, J
    Cheng, SJ
    Yuan, JQ
    Wang, CN
    Zheng, JG
    Meng, L
    Zi, ZJ
    CHINESE MEDICAL JOURNAL, 2004, 117 (10) : 1459 - 1463
  • [3] Pharmacokinetics of rapamycin-eluting stents in miniswine coronary model
    俞梦越
    高润霖
    江骥
    程树军
    袁晋青
    王春宁
    郑金刚
    孟亮
    訾振军
    Chinese Medical Journal, 2004, (10)
  • [4] Pharmacokinetics of rapamycin-eluting stents in miniswine coronary model
    俞梦越
    高润霖
    江骥
    程树军
    袁晋青
    王春宁
    郑金刚
    孟亮
    訾振军
    中华医学杂志(英文版), 2004, (10) : 18 - 22
  • [5] Rapamycin-Eluting Stents in the Arterial Duct Experimental Observations in the Pig Model
    Lee, Kyong-Jin
    Hinek, Aleksander
    Chaturvedi, Rajiv R.
    Almeida, Claudia L.
    Honjo, Osami
    Koren, Gideon
    Benson, Leland N.
    CIRCULATION, 2009, 119 (15) : 2078 - 2085
  • [6] In vitro and in vivo evaluation of Rapamycin-eluting nanofibers coated on cardia stents
    Zhu, Yueqi
    Edmonds, Laura
    Zhao, Xin
    Chen, Xinliang
    Hu, Changmin
    Cheng, Yingsheng
    Cui, Wenguo
    RSC ADVANCES, 2014, 4 (65): : 34405 - 34411
  • [7] Rapamycin-eluting stents for the treatment of unprotected left main coronary disease
    de Lezo, JS
    Medina, A
    Pan, M
    Delgado, A
    Segura, J
    Pavlovic, D
    Melián, F
    Romero, M
    Burgos, L
    Hernández, E
    Ureña, I
    Herrador, J
    AMERICAN HEART JOURNAL, 2004, 148 (03) : 481 - 485
  • [8] Restenosis after rapamycin-eluting stents for the treatment of bifurcated coronary lesions
    Pan, M
    Romero, M
    Medina, A
    de Lezo, JS
    Delgado, A
    Segura, F
    Pavlovic, DJ
    Segura, J
    EUROPEAN HEART JOURNAL, 2004, 25 : 13 - 13
  • [9] Restemosis after rapamycin-eluting stents for the treatment of bifurcated coronary lesions
    Pan, M
    de Lezo, JS
    Medina, A
    Romero, M
    Delgado, A
    Segura, J
    Hernandez, E
    Pavlovic, D
    Ojeda, S
    Ariza, J
    Femandez-Dueñas, J
    Herrador, J
    CIRCULATION, 2004, 110 (17) : 758 - 758
  • [10] Biodegradable rapamycin-eluting stents appear to stimulate late neointimal proliferation in porcine coronary model as a result of adventitial proliferation
    Zheng, JG
    Wang, CN
    Ruan, YM
    Qian, J
    Wang, QZ
    Qiao, SB
    Chin, A
    Chen, JL
    Gao, RL
    CIRCULATION, 2003, 108 (17) : 353 - 353