Parathyroid adenoma detected with 99mTc-tetrofosmin dual-phase scintigraphy: A case report

被引:1
|
作者
Romanidis K. [1 ]
Karathanos E. [2 ]
Nagorni E.-A. [1 ]
Giatromanolaki A. [3 ]
Sibridis E. [3 ]
Zissimopoulos A. [2 ]
Vogiatzaki T. [4 ]
Simopoulos C. [1 ]
Pitiakoudis M. [1 ]
机构
[1] Second Department of Surgery, Medical School, Democritus University of Thrace, Dragana
[2] Department of Nuclear Medicine, Medical School, Democritus University of Thrace, Dragana
[3] Department of Pathology, University General Hospital of Alexandroupolis, Alexandroupolis
[4] Department of Anaesthesiology, Democritus University of Thrace, Alexandroupolis
关键词
Nuclear medicine; p-glycoprotein; Parathormone; Parathyroid adenoma; Parathyroidectomy;
D O I
10.1186/1756-0500-7-335
中图分类号
学科分类号
摘要
Background: Tc-sestamibi is the most frequently used radionuclide agent for the detection of parathyroid adenomas in the clinical setting. However, Tc-tetrofosmin is another such agent that may be used for this purpose. This case report presents the significance and practicality of 99mTc- tetrofosmin for the diagnosis of parathyroid adenomas with probable high p-glycoprotein levels. Case presentation. A 45-year-old woman was referred to our Nuclear Department with a palpable neck nodule suspicious for parathyroid adenoma. She had no significant medical history or other accompanying symptoms. Blood examination results were normal with the exception of the parathormone level which was high at 167.2 pg/ml. Neck ultrasonography revealed a hypoechoic mass near the lower pole of the thyroid gland. 99m Tc-tetrofosmin dual-phase scintigraphy with early and delayed images was performed and the results supported the presupposition of parathyroid adenoma as shown by increased radiopharmaceutical levels near the lower left thyroid gland on the early image that disappeared on the delayed image. Moreover, TcO4 - thyroid scintigraphy results excluded thyroid pathology. Two months after the diagnosis, parathyroidectomy was successfully performed without postoperative complications. The pathology report and clinical response to a gradual decrease of parathormone confirmed the initial diagnosis. Conclusion: We strongly recommend the use of reverse 99m Tc-tetrofosmin scintigraphy as a useful and safe examination technique for the diagnosis of parathyroid adenomas. © 2014 Romanidis et al.; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
  • [21] 99mTc-Tetrofosmin scintigraphy and beta-2-microglobulin in Hodgkin's disease
    Vassileva, D.
    Tzonevska, A.
    Piperkova, E.
    Hrischev, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S126 - S126
  • [22] Evaluation of thyroid nodules with technetium-99m tetrofosmin dual-phase scintigraphy
    Kresnik, E
    Gallowitsch, HJ
    Mikosch, P
    Molnar, M
    Pipam, W
    Gomez, I
    Lind, P
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (07): : 716 - 721
  • [23] Evaluation of thyroid nodules with technetium-99m tetrofosmin dual-phase scintigraphy
    Kresnik E.
    Gallowitsch H.-J.
    Mikosch P.
    Molnar M.
    Pipam W.
    Gomez I.
    Lind P.
    European Journal of Nuclear Medicine, 1997, 24 (7) : 716 - 721
  • [24] Dual-phase 99mTc-sestamibi imaging and dual isotope imaging: Its utility to improve localization of parathyroid adenoma
    Jhaveri, Milan
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [25] 99mTC-tetrofosmin scintigraphy in lung carcinoma staging and follow-up evaluations
    Buccheri, G
    Biggi, A
    Ferrigno, D
    Francini, A
    CANCER, 2002, 94 (06) : 1796 - 1807
  • [26] Is dual-phase parathyroid scintigraphy for parathyroid adenoma detection necessary, or are delayed images by themselves sufficient?
    Intenzo, CM
    Kim, SM
    Miller, JL
    Capuzzi, D
    RADIOLOGY, 2002, 225 : 374 - 374
  • [27] Correlation between serum calcium levels and dual-phase 99mTc-sestamibi parathyroid scintigraphy in primary hyperparathyroidism
    Mshelia, D. S.
    Hatutale, A. N.
    Mokgoro, N. P.
    Nchabaleng, M. E.
    Buscombe, J. R.
    Sathekge, M. M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2012, 32 (01) : 19 - 24
  • [28] Predicting the response to cardiac resynchronization therapy using 99mTc-tetrofosmin myocardial scintigraphy in patients with drug-refractory heart failure: additional value of the washout of 99mTc-tetrofosmin
    Shigeru, Mayumi
    Fujiwara, Sei
    Takamine, Sachiko
    Yoshida, Akihiro
    Kawai, Hiroya
    Shiotani, Hideyuki
    Hirata, Ken-ichi
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (09) : 939 - 946
  • [29] Static 99mTc-tetrofosmin scintigraphy predicts chemotherapy response in small cell lung cancer
    Mikalauskas, V.
    Kulakiene, I.
    Saudargiene, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S270 - S270
  • [30] Cardio-renal scintigraphy with 99mTc-tetrofosmin: Feasibility and preliminary results in cardiovascular patients
    Fommei, E.
    Bruselli, L.
    Giorgetti, A.
    Gimelli, A.
    Kush, A.
    D'Aragona, I.
    Emdin, M.
    Chiacchio, S.
    Marzullo, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S140 - S141