Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor

被引:0
|
作者
Yongfeng Yang
Yun Yan
Xinfang Chen
Wenying Zhai
Yuehua Xu
Youqin Liu
机构
[1] South China Agricultural University,Institute of Biomaterial, College of Science
[2] South China Agricultural University,Instrumental Analysis & Research Center
来源
Electrocatalysis | 2014年 / 5卷
关键词
Polyaniline; Copper hexacyanoferrate; Glassy carbon; Electrocatalysis; Sulfite;
D O I
暂无
中图分类号
学科分类号
摘要
A polyaniline-coated copper hexacyanoferrate modified glassy carbon electrode (PANI/CuHCF/GC) was successfully prepared by cyclic voltammetry, which had higher electrocatalytic activity and good stability toward the oxidation of sulfite. The mechanism and main factors of influencing the electrocatalytic activity for the preparation of PANI/CuHCF/GC were investigated. The results indicated that the optimal concentration of K3Fe(CN)6–CuCl2 (molar ratio of 1:1) and aniline, scanning number of CuHCF particles deposition, and aniline polymerization were 0.6 μmol·L−1, 13, and 15, respectively. The PANI/CuHCF/GC surface properties were characterized by scanning electron microscopy and AC impedance spectra, whose results indicated that CuHCF particles evenly attached to GC surface and the electron transfer impedance was significantly reduced. Sulfite was detected by an amperometric-time (i–t) method, whose linear equation, linear range, and detection limit were Δi (μA) = 0.0624 + 46.42c mmol·L−1 (n = 15, R = 0.9978), 4.3 × 10−6 to 3.9 × 10−4 mol·L−1 and 0.6 μmol·L−1 (S/N = 3), respectively. The response time was less than 1 s. The interference of some common potential substances toward sulfite determination was studied, whose results indicated that PANI/CuHCF/GC electrode had strong anti-interference ability. The PANI/CuHCF/GC was successfully applied to the detection of sulfite in real samples with satisfactory results.
引用
收藏
页码:344 / 353
页数:9
相关论文
共 50 条
  • [31] Sensor based on Copper Nanoparticles Modified Electrochemically Activated Glassy Carbon Electrode for Paracetamol Determination
    Kassem, Mohammed A.
    Awad, Mohamed, I
    Morad, Moataz
    Aljandali, B. A.
    Pashameah, Rami Adel
    Alessa, Hussain
    Mohammed, G., I
    Sayqal, Ali
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (04):
  • [32] Sulfite determination using sulfite oxidase biosensor based glassy carbon electrode coated with thin mercury film
    Dinckaya, Erhan
    Sezginturk, Mustafa Kemal
    Akyilmaz, Erol
    Ertas, F. Nil
    FOOD CHEMISTRY, 2007, 101 (04) : 1540 - 1544
  • [33] A novel apigenin modified glassy carbon sensor electrode for the determination of copper ions in soil samples
    Mulazimoglu, Ibrahim Ender
    Solak, Ali Osman
    ANALYTICAL METHODS, 2011, 3 (11) : 2534 - 2539
  • [34] An electrochemical sensor for caffeine at a carbon nanofiber modified glassy carbon electrode
    Tsholofelo I. Sebokolodi
    Dimpo S. Sipuka
    Tebogo R. Tsekeli
    Duduzile Nkosi
    Omotayo A. Arotiba
    Journal of Food Measurement and Characterization, 2022, 16 : 2536 - 2544
  • [35] An electrochemical sensor for caffeine at a carbon nanofiber modified glassy carbon electrode
    Sebokolodi, Tsholofelo, I
    Sipuka, Dimpo S.
    Tsekeli, Tebogo R.
    Nkosi, Duduzile
    Arotiba, Omotayo A.
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2022, 16 (04) : 2536 - 2544
  • [36] Electrochemical performance of polyaniline-coated γ-MnO2 on carbon cloth as flexible electrode for supercapacitor
    Zhu, Yuanqiang
    Xu, Hui
    Chen, Pengdong
    Bao, Yuanhai
    Jiang, Xudong
    Chen, Yong
    ELECTROCHIMICA ACTA, 2022, 413
  • [37] Selective Detection of Glucose by Linear Sweep Voltammetry Using a Copper-Polyaniline Modified Glassy Carbon Electrode
    Mirzavand, P.
    Zargar, B.
    Pourreza, N.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2024, 60 (05) : 400 - 410
  • [38] Electrocatalytic oxidation of deoxyguanosine on a glassy carbon electrode modified with a ruthenium oxide hexacyanoferrate film
    Paixao, Thiago R. L. C.
    Bertotti, Mauro
    ELECTROCHIMICA ACTA, 2007, 52 (05) : 2181 - 2188
  • [39] Cobalt(II)hexacyanoferrate film modified glassy carbon electrode for construction of a glucose biosensor
    Zhang, JZ
    Dong, SJ
    ANALYTICAL LETTERS, 1999, 32 (15) : 2925 - 2936
  • [40] Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
    Alamo, Lori Shayne T.