Highly Sensitive and Selective Uric Acid Biosensor Based on Direct Electron Transfer of Hemoglobin-encapsulated Chitosan-modified Glassy Carbon Electrode

被引:0
|
作者
Changzhi Zhao
Li Wan
Qin Wang
Shufeng Liu
Kui Jiao
机构
[1] Qingdao University of Science & Technology,Key Laboratory of Eco
来源
Analytical Sciences | 2009年 / 25卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A uric acid biosensor based on the direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode was developed for a highly sensitive and selective analysis in urine samples. The modified electrode was prepared by the encapsulation of hemoglobin and uricase in a chitosan matrix. The hydrogen peroxide produced from the catalytic oxidation of uric acid by uricase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to uric acid. The linear response of the uric acid concentrations ranged from 2.00 to 30.0 µM with a correlation of 0.9982, the detection limit of uric acid was estimated to be 0.85 µM at a signal/noise ratio of 3. The uric acid biosensor can efficiently exclude the interference of commonly coexisted ascorbic acid, dopamine, epinephrine, etc. The relative standard deviation was under 2.56% (n = 5) for the determination of real samples. This biosensor is satisfactory for the determination of human urine samples compared with the HPLC-UV method.
引用
收藏
页码:1013 / 1017
页数:4
相关论文
共 50 条
  • [21] Graphitized mesoporous carbon modified glassy carbon electrode for selective sensing of xanthine, hypoxanthine and uric acid
    Thangaraj, Rajendiran
    Kumar, Annamalai Senthil
    ANALYTICAL METHODS, 2012, 4 (07) : 2162 - 2171
  • [22] Direct electron transfer and bioelectrocatalysis of hemoglobin on nano-structural attapulgite clay-modified glassy carbon electrode
    Xu, Jiming
    Li, Wei
    Yin, Qifan
    Zhong, Hui
    Zhu, Yulan
    Jin, Litong
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2007, 315 (01) : 170 - 176
  • [23] A reagentless nitrite biosensor based on direct electron transfer of hemoglobin on a room temperature ionic liquid/carbon nanotube-modified electrode
    Wei, Wei
    Jin, Hui-Hui
    Zhao, Guang-Chao
    MICROCHIMICA ACTA, 2009, 164 (1-2) : 167 - 171
  • [24] A reagentless nitrite biosensor based on direct electron transfer of hemoglobin on a room temperature ionic liquid/carbon nanotube-modified electrode
    Wei Wei
    Hui-Hui Jin
    Guang-Chao Zhao
    Microchimica Acta, 2009, 164 : 167 - 171
  • [25] Fabrication of Cetyltrimethylammonium Bromide/chitosan Modified Glassy Carbon Electrode for Simultaneous Determination of Uric Acid and Ascorbic Acid
    Zhang, Ying
    Luo, Li-Qiang
    Ding, Ya-Ping
    Li, Qiu-Xia
    Shen, Xia
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (5A) : 1061 - 1066
  • [26] A hydrogen peroxide biosensor based on direct electron transfer from hemoglobin to an electrode modified with Nafion and activated nanocarbon
    Jie Song
    JiMing Xu
    PuSu Zhao
    LuDe Lu
    JianChun Bao
    Microchimica Acta, 2011, 172 : 117 - 123
  • [27] Amperometric uric acid biosensor based on poly(vinylferrocene)-gelatin-carboxylated multiwalled carbon nanotube modified glassy carbon electrode
    Erden, Pinar Esra
    Kacar, Ceren
    Ozturk, Funda
    Kilic, Esma
    TALANTA, 2015, 134 : 488 - 495
  • [28] A hydrogen peroxide biosensor based on direct electron transfer from hemoglobin to an electrode modified with Nafion and activated nanocarbon
    Song, Jie
    Xu, JiMing
    Zhao, PuSu
    Lu, LuDe
    Bao, JianChun
    MICROCHIMICA ACTA, 2011, 172 (1-2) : 117 - 123
  • [29] Direct electron transfer of horseradish peroxidase and its biosensor based on gold nanoparticles/chitosan/ITO modified electrode
    Xiang, Cuili
    Zou, Yongjin
    Sun, Li-Xian
    Xu, Fen
    ANALYTICAL LETTERS, 2008, 41 (12) : 2224 - 2236
  • [30] Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices
    Gabriel, Ellen F. M.
    Garcia, Paulo T.
    Cardoso, Thiago M. G.
    Lopes, Flavio M.
    Martins, Felipe T.
    Coltro, Wendell K. T.
    ANALYST, 2016, 141 (15) : 4749 - 4756