A patient-specific lumped-parameter model of coronary circulation

被引:0
|
作者
Zheng Duanmu
Min Yin
Xueling Fan
Xilan Yang
Xiaoyu Luo
机构
[1] Xi’an Jiaotong University,State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace Engineering
[2] The Second Affiliated Hospital of Nanjing Medical University,School of Mathematics & Statistics
[3] University of Glasgow,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A new lumped-parameter model for coronary hemodynamics is developed. This model is developed for the whole coronary network based on CT scans of a patient-specific geometry including the right coronary tree, which is absent in many previous mathematical models. The model adopts the structured tree model boundary conditions similar to the work of Olufsen et al., thus avoiding the necessity of invasive perfusion measurements. In addition, we also incorporated the effects of the head loss at the two inlets of the large coronary arteries for the first time. The head loss could explain the phenomenon of a sudden increase of the resistance at the inlet of coronary vessel. The estimated blood pressure and flow rate results from the model agree well with the clinical measurements. The computed impedances also match the experimental perfusion measurement. The effects of coronary arterial stenosis are considered and the fractional flow reserve and relative flow in the coronary vessels for a stenotic vessel computed in this model show good agreement with published experimental data. It is believed that the approach could be readily translated to clinical practice to facilitate real time clinical diagnosis.
引用
收藏
相关论文
共 50 条
  • [21] Study on Lumped-parameter Model of Surface Circular Foundation
    Wang, Hai
    Liu, Weiqing
    Wang, Shuguang
    Du, Dongsheng
    Zhou, Ding
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 261-263 : 980 - 984
  • [22] A lumped-parameter transducer model for piezoelectric and ferroelectret polymers
    Karki, Satu
    Lekkala, Jukka
    MEASUREMENT, 2012, 45 (03) : 453 - 458
  • [23] Physically motivated lumped-parameter model for proportional magnets
    Reinertz, Olivier
    INTERNATIONAL JOURNAL OF FLUID POWER, 2018, 19 (03) : 140 - 151
  • [24] Lumped-parameter model of pile group impedance function
    Liu, Wei-Qing
    Wang, Hai
    Wang, Shu-Guang
    Du, Dong-Sheng
    Li, Wei-Wei
    Zhendong yu Chongji/Journal of Vibration and Shock, 2011, 30 (11): : 249 - 253
  • [25] A LUMPED-PARAMETER MODEL FOR DYNAMIC MR DAMPER CONTROL
    Case, David
    Taheri, Behzad
    Richer, Edmond
    PROCEEDINGS OF THE ASME 2013 DYNAMIC SYSTEMS AND CONTROL CONFERENCE (DSCC2013), VOL. 1, 2013,
  • [26] A Lumped-Parameter Subject-Specific Model of Blood Volume Response to Fluid Infusion
    Bighamian, Ramin
    Reisner, Andrew T.
    Hahn, Jin-Oh
    FRONTIERS IN PHYSIOLOGY, 2016, 7
  • [27] LUMPED-PARAMETER MODEL FOR HEMODIALYZER WITH APPLICATION TO SIMULATION OF PATIENT-ARTIFICIAL-KIDNEY SYSTEM
    RAMACHANDRAN, PA
    MASHELKAR, RA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (02) : 179 - 188
  • [28] LUMPED-PARAMETER MODEL OF MASS TRANSFER IN HEMODIALYZER WITH ULTRAFILTRATION
    张凤宝
    张国亮
    陈涛
    王绍亭
    Chinese Journal of Chemical Engineering, 1995, (01) : 60 - 65
  • [29] NONLINEAR DYNAMIC LUMPED-PARAMETER MODEL OF A RECTANGULAR PLATE
    BAYLES, DJ
    BOYD, DE
    LOWERY, RL
    JOURNAL OF SOUND AND VIBRATION, 1972, 21 (03) : 329 - &