The influence of titanium coating of mesh polypropylene endoprostheses on their biocompatibility

被引:0
|
作者
Babichenko I.I. [1 ]
Kazantsev A.A. [2 ]
Titarov D.L. [1 ]
Shemyatovskii K.A. [1 ]
Gevondyan N.M. [3 ]
Melchenko D.S. [2 ]
Alekhin A.I. [2 ]
机构
[1] Peoples’ Friendship University of Russia, Moscow
[2] Central Clinical Hospital of the Russian Academy of Sciences, Moscow
[3] Shemyakin and Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Moscow
关键词
collagen type I and III; Ki-67; mesh materials; polypropylene; titanium-coated polypropylene;
D O I
10.1134/S1990519X16040027
中图分类号
学科分类号
摘要
A comparative analysis of the proliferative activity of inflammatory infiltrate cells and the distribution of collagen type I and III in granulomas formed in the area of contact of mesh materials made of polypropylene (PP Std Light) and titanium-coated polypropylene (TiMesh) was performed via polarized microscopy and immunohistochemical detection of Ki-67 protein. Mesh materials were implanted in the soft tissues of the lumbar region of rats. The number of proliferative cells around implants made of the standard polypropylene (PP Std Light) 7 days after the operation was detected with the use of antibodies to Ki-67 protein to be less than the number of those around titanium-coated polypropylene (TiMesh) (29.1 ± 5.7 and 33.6 ± 3.1%, respectively, p < 0.001). The similar differences were revealed 1 month after the beginning of the experiment (15.9 ± 4.3 and 26.9 ± 3.6%, respectively, p < 0.001). Various types of collagen fibers in granulomas around the implanted mesh materials were detected in polarized light with the use of sections stained with Sirius Red. The ratios between collagen fibers type I and III in granulomas around PP Std Light and TiMesh materials determined 7 days after the operation were 1.085 ± 0.022 and above 1.107 ± 0.013, respectively (p = 0.017). The ratio increased to 1.174 ± 0.036 and 1.246 ± 0.102, respectively (p = 0.045) 1 month after the operation. The obtained results suggest that the titanium coating of polypropylene stimulates the formation of collagen type I and more mature connective tissue around mesh endoprostheses. © 2016, Pleiades Publishing, Ltd.
引用
收藏
页码:332 / 339
页数:7
相关论文
共 50 条
  • [21] Preparation and biocompatibility evaluation of polypropylene mesh coated with electrospinning membrane for pelvic defects repair
    Lu, Yao
    Fu, Shaoju
    Zhou, Shuanglin
    Chen, Ge
    Zhu, Chaoting
    Li, Nannan
    Ma, Ying
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 81 : 142 - 148
  • [22] Corrosion resistance and biocompatibility of SrHAp/ZnO composite implant coating on titanium
    Huang, Yong
    Zeng, Hongjuan
    Wang, Xuexin
    Wang, Deshun
    APPLIED SURFACE SCIENCE, 2014, 290 : 353 - 358
  • [23] Influence of polyglactin-coating on functional and morphological parameters of polypropylene-mesh modifications for abdominal wall repair
    Klinge, U
    Klosterhalfen, B
    Müller, M
    Anurov, M
    Öttinger, A
    Schumpelick, V
    BIOMATERIALS, 1999, 20 (07) : 613 - 623
  • [24] Effect of Silicon Nitride Coating on Titanium Surface: Biocompatibility and Antibacterial Properties
    Tani, Akina
    Tsubouchi, Harumitsu
    Ma, Lin
    Taniguchi, Yurie
    Kobayashi, Yasuyuki
    Nakai, Mariko
    Komasa, Satoshi
    Hashimoto, Yoshiya
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (17)
  • [25] Biocompatibility and Antibacterial property of Cold Sprayed ZnO/Titanium Composite Coating
    Sanpo, Noppakun
    Hailan, Chen
    Loke, Kelvin
    Keng, Koh Pak
    Cheang, Philip
    Berndt, C. C.
    Khor, K. A.
    SCIENCE AND TECHNOLOGY AGAINST MICROBIAL PATHOGENS: RESEARCH, DEVELOPMENT AND EVALUATION, 2011, : 140 - 144
  • [26] Biocompatibility of a titanium-aluminum nitride film coating on a dental alloy
    Chung, KH
    Liu, GT
    Duh, JG
    Wang, JH
    SURFACE & COATINGS TECHNOLOGY, 2004, 188 (1-3 SPEC.ISS.): : 745 - 749
  • [27] Preparation, Characterization and Biocompatibility of Bioactive Coating on Titanium by Plasma Electrolytic Oxidation
    Ji, Dong-Dong
    Xu, Jin-Yu
    Gu, Xiao-Feng
    Gao, Ai-Guo
    Zhao, Quan-Ming
    SCIENCE OF ADVANCED MATERIALS, 2019, 11 (10) : 1411 - 1415
  • [28] Influence of TiN coating on the biocompatibility of medical NiTi alloy
    Jin, Shi
    Zhang, Yang
    Wang, Qiang
    Zhang, Dan
    Zhang, Song
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 101 : 343 - 349
  • [29] Influence of Electropolishing and Magnetoelectropolishing on Corrosion and Biocompatibility of Titanium Implants
    Rahman, Zia Ur
    Pompa, Luis
    Haider, Waseem
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2014, 23 (11) : 3907 - 3915
  • [30] Influence of Electropolishing and Magnetoelectropolishing on Corrosion and Biocompatibility of Titanium Implants
    Zia ur Rahman
    Luis Pompa
    Waseem Haider
    Journal of Materials Engineering and Performance, 2014, 23 : 3907 - 3915