Electrocatalytic Determination of Ascorbic Acid on a Glassy Carbon Electrode Chemically Modified with Cobalt Pentacyanonitrosylferrate

被引:0
|
作者
Reza Emamali Sabzi
Mohammad Hussein Pournaghi-Azar
机构
[1] Urmia University,Department of Chemistry, Faculty of Science
[2] Tabriz University,Electroanalytical Chemistry Laboratory, Faculty of Chemistry
来源
Analytical Sciences | 2005年 / 21卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An electrochemically prepared thin film of cobalt pentacyanonitrosylferrate (GC/CoPCNF) was used as a surface modifier for glassy carbon electrodes. The oxidation of ascorbic acid on a glassy carbon electrode modified with GC/CoPCNF as a working electrode was studied using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry in a 0.25 M KNO3 + 0.25 M phosphate buffer (pH 7) solution. The glassy carbon modified with CoPCNF showed good electrocatalytic activity toward ascorbic acid oxidation. The kinetics of the catalytic reaction was investigated, and the average value of the rate constant (k) for the catalytic reaction and the diffusion coefficient (D) were evaluated by different approaches for ascorbic acid, and were found to be 3.3 ± 0.3 × 102 M−1 s−1 and 3.2 ± 0.3 × 10−6 cm2 s−1, respectively.
引用
收藏
页码:689 / 692
页数:3
相关论文
共 50 条
  • [31] Fabrication of a Polyglycine Chemically Modified Electrode and Its Electrocatalytic Oxidation to Ascorbic Acid
    Department of Chemistry, Nanjing University, Nanjing 210093, China
    Electroanalysis, 10 (788-790):
  • [32] Fabrication of a Polyglycine Chemically Modified Electrode and Its Electrocatalytic Oxidation to Ascorbic Acid
    Yu, A.-M.
    Zhang, H.-L.
    Chen, H.-Y.
    Electroanalysis, 9 (10):
  • [33] Simultaneous Determination of Dopamine, Serotonin and Ascorbic Acid at a Glassy Carbon Electrode Modified with Carbon-Spheres
    Zhou, Jianqing
    Sheng, Meili
    Jiang, Xueyue
    Wu, Guozhi
    Gao, Feng
    SENSORS, 2013, 13 (10): : 14029 - 14040
  • [34] Determination of dopamine in the presence of ascorbic acid using poly(hippuric acid) modified glassy carbon electrode
    Zhao, H
    Zhang, YH
    Yuan, ZB
    ELECTROANALYSIS, 2002, 14 (14) : 1031 - 1034
  • [35] Determination of Acetaminophen in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Poly(Caffeic acid)
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Cetintas, Gamze
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (01): : 148 - 160
  • [36] Determination of dopamine in the presence of ascorbic acid using a poly(amidosulfonic acid) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Yang, ZS
    Zhao, H
    MICROCHIMICA ACTA, 2004, 147 (04) : 225 - 230
  • [37] Determination of Dopamine in the Presence of Ascorbic Acid Using a Poly(Amidosulfonic Acid) Modified Glassy Carbon Electrode
    Yuzhong Zhang
    Guiying Jin
    Zhousheng Yang
    Hong Zhao
    Microchimica Acta, 2004, 147 : 225 - 230
  • [38] Electro-oxidation of ascorbic acid catalyzed on cobalt hydroxide-modified glassy carbon electrode
    Karim-Nezhad, Ghasem
    Hasanzadeh, Mohammad
    Saghatforoush, Lotfali
    Shadjou, Nasrin
    Khalilzadeh, Balal
    Ershad, Sohrab
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2009, 74 (05) : 581 - 593
  • [39] The electroreduction of carbon dioxide by macrocyclic cobalt complexes chemically modified on a glassy carbon electrode
    Aga, H
    Aramata, A
    Hisaeda, Y
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 437 (1-2): : 111 - 118
  • [40] Electrochemical Determination of Ascorbic Acid Based on AgNPs/PVP-Modified Glassy Carbon Electrode
    Karaboduk, Kuddusi
    CHEMISTRYSELECT, 2019, 4 (20): : 6361 - 6369