On the Importance of Testing Gravity at Distances Less Than 1cm

被引:0
|
作者
Silas R. Beane
机构
来源
关键词
VACUUM ENERGY; TESTS OF NEWTON'S LAW; UNOBSERVED QUANTA;
D O I
暂无
中图分类号
学科分类号
摘要
If the mechanism responsible for the smallness of the vacuum energy is consistent with local quantum field theory, general arguments suggest the existence of at least one unobserved scalar particle with Compton wavelength bounded from below by one tenth of a millimeter. We show that this bound is saturated if vacuum energy is a substantial component of the energy density of the universe. Therefore, the success of cosmological models with a significant vacuum energy component suggests the existence of new macroscopic forces with range in the sub-millimeter region. There are virtually no experimental constraints on the existence of quanta with this range of interaction.
引用
收藏
页码:945 / 951
页数:6
相关论文
共 50 条
  • [31] Surgical outcomes of lung cancer measuring less than 1 cm in diameter
    Hamatake, Daisuke
    Yoshida, Yasuhiro
    Miyahara, So
    Yamashita, Shin-ichi
    Shiraishi, Takeshi
    Iwasaki, Akinori
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 15 (05) : 854 - 858
  • [32] IR DICHROISM OF MUSCOVITE ABSORPTIONS LESS THAN 1200 CM-1
    STEGER, E
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1976, 32 (05) : 1125 - 1128
  • [33] EMR achieves similar oncological outcomes as ESD for gastric neoplasia of <1cm, requiring less expertise, training and time
    Banks, Matthew
    Uedo, Noriya
    Bhandari, Pradeep
    Gotoda, Takuji
    [J]. GUT, 2020, 69 (09) : 1712 - +
  • [34] 1cm以下的早期胃癌X线研究
    王成林
    [J]. 国际医学放射学杂志, 1992, (05) : 308 - 308
  • [35] Testing Newtonian gravity at ultra-short distances
    Krause, DE
    Fischbach, E
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 2001, 10 (01): : 25 - 31
  • [36] The group of fractions of a torsion free 1cm monoid is torsion free
    Dehornoy, P
    [J]. JOURNAL OF ALGEBRA, 2004, 281 (01) : 303 - 305
  • [37] Geoid interpolation in Gongzhuling City and the 1cm quasi geoid refinement
    WANG Yongchun
    ZHONG Linshan
    ZHAO Han
    WU Qiong
    [J]. Global Geology, 2024, 27 (04) : 207 - 215
  • [38] 1cm剂量当量的适用性研究
    魏木水
    [J]. 中国辐射卫生, 1999, (04) : 211 - 211
  • [39] 直径≤1cm的直肠类癌诊治探讨
    汪嵘
    陈星
    原丽莉
    [J]. 山西医药杂志, 2006, (10) : 869 - 870
  • [40] INVESTIGATION OF 1CM DOSE EQUIVALENT FOR PHOTONS BEHIND SHIELDING MATERIALS
    HIRAYAMA, H
    TANAKA, S
    [J]. JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1989, 31 (07): : 841 - 851