Scatter Correction in Cone Beam CT for Metal Additive Manufacturing Components

被引:0
|
作者
Xiaoqin Xia
Xiaodong Hu
Zhenye Han
Dong Zhang
Ying Xu
Jing Zou
机构
[1] Tianjin University,State Key Laboratory of Precision Measuring Technology and Instruments
[2] Guangdong University of Technology,School of Electro
[3] Beijing Center for Mathematics and Information Interdisciplinary Sciences (BCMIIS),mechanical Engineering
来源
JOM | 2019年 / 71卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This paper provides an x-ray scatter correction method for cone beam computed tomography (CT) to reduce cupping artifacts and image inhomogeneity of metal additive manufacturing (AM) components. Firstly, projections in 360° were obtained by a cone beam CT system. Secondly, the corresponding virtual CT system was built on Geant4 to obtain scatter photons. Different from previous studies, the geometry of the metal AM component was set by importing a CAD model of the component into Geant4, which can not only assure the accuracy of geometry but also simplify the definition of the geometry. Finally, the corresponding scatter photons were subtracted from the experimental projections in 360° to obtain corrected projections. Corrected reconstruction images were acquired via an FDK algorithm. In the corrected images, the average sum of squares of deviation of regions of interest was about 79.5% of that in the uncorrected images. Corrected images showed that cupping-shaped artifacts and image inhomogeneity were effectively reduced.
引用
收藏
页码:1082 / 1087
页数:5
相关论文
共 50 条
  • [31] Scatter correction method for cone-beam CT based on interlacing-slit scan
    黄魁东
    张华
    史仪凯
    张亮
    徐哲
    [J]. Chinese Physics B, 2014, 23 (09) : 519 - 525
  • [32] Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies
    Cai, Weixing
    Ning, Ruola
    Conover, David
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) : 91 - 109
  • [33] Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm
    Li, Jun
    Yao, Weiguang
    Xiao, Ying
    Yu, Yan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 167 - 176
  • [34] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    [J]. OPTICAL ENGINEERING, 2017, 56 (06)
  • [35] A new X-ray scatter correction method based on BAG for cone beam CT
    Geng, Ping
    Teng, Fei
    Xiao, Dayu
    Kang, Yan
    [J]. PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 326 - 329
  • [36] X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT
    Aootaphao, Sorapong
    Thongvigitmanee, Saowapak S.
    Rajruangrabin, Jartuwat
    Thanasupsombat, Chalinee
    Srivongsa, Tanapon
    Thajchayapong, Pairash
    [J]. BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [37] Local filtration based scatter correction for cone-beam CT using primary modulation
    Zhu, Lei
    [J]. MEDICAL PHYSICS, 2016, 43 (11) : 6199 - 6209
  • [38] Development of a Beam Stop Array System with Dual Scan Mode for Scatter Correction of Cone-beam CT
    Ahn, So Hyun
    Choi, Jinho
    Lee, Kyu Chan
    Kim, Siyong
    Lee, Rena
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) : 1220 - 1229
  • [39] An unsupervised dual contrastive learning framework for scatter correction in cone-beam CT image
    Wang, Tangsheng
    Liu, Xuan
    Dai, Jingjing
    Zhang, Chulong
    He, Wenfeng
    Liu, Lin
    Chan, Yinping
    He, Yutong
    Zhao, Hanqing
    Xie, Yaoqin
    Liang, Xiaokun
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 165
  • [40] Optimization of the Design of a Moving Blocker for Cone-Beam CT Scatter Correction: Experimental Evaluation
    Chen, X.
    Ouyang, L.
    Yan, H.
    Jia, X.
    Zhang, Y.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3799 - 3799