Stochastic seismic analysis of base-isolated structures with electromagnetic inertial mass dampers considering different soil conditions

被引:0
|
作者
Heng Wang
Wenai Shen
Hongping Zhu
Fan Kong
Songye Zhu
机构
[1] Huazhong University of Science and Technology,School of Civil and Hydraulic Engineering
[2] Huazhong University of Science and Technology,Hubei Key Laboratory of Control Structure
[3] Wuhan University of Technology,Department of Building Engineering
[4] The Hong Kong Polytechnic University,Department of Civil and Environmental Engineering
来源
关键词
Base-isolated structure; Inerter; Electromagnetic inertial mass damper; Stochastic seismic response; Optimal parameters; Soil conditions;
D O I
暂无
中图分类号
学科分类号
摘要
An electromagnetic inertial mass damper (EIMD) is an inerter-based damper that can significantly enhance the seismic performance of a frame structure. However, the stochastic seismic analysis of a base-isolated structure (BIS) with the EIMD subjected to earthquake ground motions has rarely been reported. Based on a probabilistic framework, this paper studies the stochastic seismic responses of the BIS with the EIMD subjected to seismic excitations considering three typical soil conditions. The analytical solutions of the response variances of a two-degree-of-freedom (2DOF) BIS-EIMD system are derived considering both stationary and non-stationary seismic excitations. A parametric study on the BIS-EIMD system subjected to stochastic seismic excitations modeled by filtered Kanai-Tajimi spectrum is conducted to investigate the different seismic responses under firm, medium, and soft soil conditions, and the corresponding optimal inertance and damping of the EIMD are obtained by minimizing the stochastic seismic responses of the superstructure or the base floor. The results of the 2DOF BIS-EIMD system indicate that the optimal EIMD achieves comparable control performance under the three soil conditions, but the optimal parameters of the EIMD vary significantly under different soil conditions. Under soft soil conditions, the BIS-EIMD system requires a much larger inertance setting compared with that of the firm and medium soil conditions. A numerical simulation of a seven-story isolated building with an EIMD is conducted considering both artificial seismic excitations and real earthquake ground motions. Numerical results show that the EIMD is capable of significantly suppressing the seismic responses of both the base floor and the superstructure, which is better than that of a conventional viscous damper.
引用
收藏
页码:1601 / 1626
页数:25
相关论文
共 50 条
  • [41] A modal procedure for seismic analysis of non-linear base-isolated multistorey structures
    Dipt di Ingegneria Civile, Seconda Univ di Napoli, via Roma 29, Aversa, Caserta 81031, Italy
    Earthquake Eng Struct Dyn, 4 (397-412):
  • [42] A modal procedure for seismic analysis of non-linear base-isolated multistorey structures
    Malangone, P
    Ferraioli, M
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1998, 27 (04): : 397 - 412
  • [43] Analysis of base-isolated buildings considering vertical seismic responses and P-delta effects
    Zhao, YM
    Ma, DH
    Guo, XD
    Su, JY
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 745 - 749
  • [44] Seismic performance improvement of base-isolated structures using a semi-active tuned mass damper
    Wang, Liangkun
    Nagarajaiah, Satish
    Shi, Weixing
    Zhou, Ying
    ENGINEERING STRUCTURES, 2022, 271
  • [45] Seismic Fragility and Reliability of Base-Isolated Structures with Regard to Superstructure Ductility and Isolator Displacement Considering Degrading Behavior
    Delaviz, Arman
    Yaghmaei-Sabegh, Saman
    Souri, Omid
    JOURNAL OF EARTHQUAKE ENGINEERING, 2024, 28 (14) : 3973 - 4002
  • [46] Simplified inelastic seismic analysis of base-isolated structures using the N2 method
    Kilar, Vojko
    Koren, David
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (09): : 967 - 989
  • [47] Seismic response of base-isolated liquid storage tanks considering fluid-structure-soil interaction in time domain
    Cho, KH
    Kim, MK
    Lim, YM
    Cho, SY
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2004, 24 (11) : 839 - 852
  • [48] Hybrid system of base-isolated structures with tuned tandem mass damper-inerters considering internal friction
    Li, Xin
    Wang, Zhihao
    Pan, Hang
    Cao, Liyuan
    Li, Chunxiang
    JOURNAL OF BUILDING ENGINEERING, 2025, 101
  • [49] Seismic response and hysteric performance analysis in different base isolated structures
    Yuan, Ying
    Zhou, Aihong
    Gao, Yanli
    ADVANCES IN CIVIL INFRASTRUCTURE ENGINEERING, PTS 1 AND 2, 2013, 639-640 : 891 - 895
  • [50] Dynamic analysis of base-isolated structures by considering the nonlinear behavior of elastomeric bearings and variation of damping ratios
    Zhang, Yu-Liang
    Wang, Yang
    Zhang, Tong-Sheng
    Gongcheng Lixue/Engineering Mechanics, 2002, 19 (02): : 58 - 63