Cyclic shear tests on RC precast beam-to-column connections retrofitted with a three-hinged steel device

被引:0
|
作者
Gennaro Magliulo
Maddalena Cimmino
Marianna Ercolino
Gaetano Manfredi
机构
[1] University of Naples Federico II,Department of Structures for Engineering and Architecture
[2] University of Naples Federico II,Construction Technologies Institute URT Naples, National Research Council of Italy, DiSt
[3] University of Greenwich,Department of Engineering Science
来源
关键词
RC precast buildings; Beam-to-column connections; Cyclic shear tests; Seismic retrofitting; Three-hinged steel system;
D O I
暂无
中图分类号
学科分类号
摘要
Recent European earthquakes demonstrated that the seismic response of RC precast structures can be significantly influenced by the connection systems. Moreover, during past seismic events, many failures of the beam-to-column connections occurred due to their inadequate strength under seismic loads. The seismic safety of these connections has a crucial role in the overall seismic capacity of existing precast structures. A new connection system is employed as a retrofitting solution for a damaged beam-to-column connection and its cyclic shear performance is investigated by means of two cyclic shear tests on two different configurations. In both the experimental tests, the results demonstrate an efficient behavior of the retrofitted connections under horizontal cyclic loads. The comparison between the performance of the investigated connection and the response of a typical beam-to-column dowel connection allows to discuss the main critical features of the dowel connection system.
引用
收藏
页码:3797 / 3817
页数:20
相关论文
共 50 条
  • [41] Cyclic behaviour of welded stainless steel beam-to-column connections: Experimental and numerical study
    Wei, Xiaojun
    Zhou, Hao
    Kamaris, George S.
    Gkantou, Michaela
    Yun, Feiyu
    Zuo, Xianglong
    Guo, Xinran
    Bin Ali, Shafayat
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 218
  • [42] Cyclic-Loading Performance of Steel Beam-to-Column Moment Connections to an I-Section Column
    Somarriba, Martin
    Okazaki, Taichiro
    Zhao, Junxian
    Komatsu, Kensuke
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (04)
  • [43] Effectiveness of Perforated Shear Panels for Improving the Failure Modes of Beam-to-Column Connections in Steel Shear Walls
    Ahmadi, Hadi Monsef
    De Matteis, Gianfranco
    Mazzolani, Federico M.
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 667 - 675
  • [44] Cyclic testing and parametric study of bolted beam-height adjustable steel beam-to-column connections
    Zhenggang Cao
    Peng Du
    Feng Fan
    Jiangdong Li
    International Journal of Steel Structures, 2017, 17 : 77 - 89
  • [45] EXPERIMENTAL-OBSERVATIONS ON THE SEISMIC SHEAR PERFORMANCE OF RC BEAM-TO-COLUMN CONNECTIONS SUBJECTED TO VARYING AXIAL COLUMN FORCE
    AGBABIAN, MS
    HIGAZY, EM
    ABDELGHAFFAR, AM
    ELNASHAI, AS
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1994, 23 (08): : 859 - 876
  • [46] Cyclic tests on high strength steel flange-plate beam-to-column joints
    Chen Xuesen
    Shi Gang
    ENGINEERING STRUCTURES, 2019, 186 : 564 - 581
  • [47] Cyclic tests on bolted steel and composite double-sided beam-to-column joints
    Dubina, D
    Ciutina, AL
    Stratan, A
    STEEL & COMPOSITE STRUCTURES, 2002, 2 (02) : 147 - 160
  • [48] Experimental investigation of prefabricated beam-to-column steel joints for precast concrete structures under cyclic loading
    Li, Zuohua
    Qi, Yihe
    Teng, Jun
    ENGINEERING STRUCTURES, 2020, 209
  • [49] Cyclic Behaviour of Fully-Rigid and Semi-Rigid Steel Beam-to-Column Connections
    Iman Faridmehr
    Mamood Md. Tahir
    Mohd Hanim Osman
    Mohammadamin Azimi
    International Journal of Steel Structures, 2020, 20 : 365 - 385
  • [50] Cyclic Behaviour of Fully-Rigid and Semi-Rigid Steel Beam-to-Column Connections
    Faridmehr, Iman
    Tahir, Mamood Md
    Osman, Mohd Hanim
    Azimi, Mohammadamin
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (02) : 365 - 385