A New Calibration Apparatus of Port Quick Leak Detector for Spacecraft

被引:0
|
作者
Lan Zhao
Yongjun Cheng
Wenjun Sun
Yongjun Wang
Lian Chen
Xuemin Sheng
Ruifang Zhang
Meiru Guo
Yanwu Li
机构
[1] Lanzhou Institute of Physics,Science and Technology on Vacuum Technology and Physics Laboratory
来源
MAPAN | 2018年 / 33卷
关键词
Calibration apparatus; Port quick leak detector; Direct comparison calibration method; Pressure-rising method;
D O I
暂无
中图分类号
学科分类号
摘要
The leak rate of spacecraft port must meet certain standards during the opening and closing processes. The port quick leak detector can be used to on-line measure leak rates of spacecraft port. In this work, a new calibration apparatus is designed and investigated. It can work at different temperatures with different gases in a wide leak rate range. This apparatus consists of the standard leak rate system, calibration system, temperature control system, gas supply and pumping system, which is designed on the basis of direct comparison calibration method and pressure-rising method with a constant volume, and the leak rates are provided by the standard leak rate system. The calibration range of the calibration apparatus is from 2 × 10–6 to 2 × 10–2 Pa m3/s. Its combined standard uncertainty is about 4.7%, and its calibration temperature is from − 50 to 20 °C. Within the above leak rate and temperature ranges, the correction factor of the port quick leak detector is about 0.88–1.09.
引用
收藏
页码:91 / 97
页数:6
相关论文
共 50 条
  • [31] NEW CALIBRATION METHOD FOR A 7-PORT REFLECTOMETER
    LUFF, GF
    PROBERT, PJ
    CARROLL, JE
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1987, 134 (07): : 595 - 600
  • [32] A NEW CALIBRATION METHOD FOR THE 4-PORT REFLECTOMETER
    WU, HX
    LIU, DQ
    PAN, CH
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1992, 5 (09) : 423 - 427
  • [33] New calibration procedure for the microrespirometer and blood gas apparatus
    Wust, J
    ZEITSCHRIFT FUR BIOLOGIE, 1931, 92 (02): : 144 - 162
  • [34] Quantitative evaluation of leak rates in pressure type helium leak tests - A new methodology for system calibration
    Gurunathan, T
    Thiyagarajan, R
    Subramanian, AR
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1257 - 1260
  • [35] A new calibration method for radon detector in seismic systems
    Ren, Hongwei
    Liu, Yaowei
    EARTHQUAKE SCIENCE, 2024, 37 (05) : 445 - 458
  • [36] A New Method for Calibration of Gain Variation in a Detector System
    Goda, Shohei
    Matsuo, Taro
    ASTRONOMICAL JOURNAL, 2018, 156 (06):
  • [37] New Interpretation of Signals and In-Reactor Detector Calibration
    V. V. Postnikov
    A. M. Evdokimov
    I. S. Yakunin
    A. E. Volkov
    O. E. Zhukov
    V. V. Petrov
    Atomic Energy, 2013, 114 : 399 - 403
  • [38] New Interpretation of Signals and In-Reactor Detector Calibration
    Postnikov, V. V.
    Evdokimov, A. M.
    Yakunin, I. S.
    Volkov, A. E.
    Zhukov, O. E.
    Petrov, V. V.
    ATOMIC ENERGY, 2013, 114 (06) : 399 - 403
  • [39] Design principle and performance evaluation of a new-type leak detector
    Horikoshi, G
    Kobayashi, M
    VACUUM, 1996, 47 (6-8) : 531 - 534
  • [40] Design principle and performance evaluation of a new-type leak detector
    Natl Lab for High Energy Physics, , Ibaraki-ken, Japan
    Vacuum, 6-8 (531-534):