All-inside meniscal repair using the FasT-Fix meniscal repair system: Is still needed to avoid weight bearing? A systematic review

被引:27
|
作者
Alberto Vascellari
Enrico Rebuzzi
Stefano Schiavetti
Nicolò Coletti
机构
[1] Oderzo Hospital,Orthopaedic and Traumatology Department
关键词
Meniscal repair; Arthroscopic meniscus repair; All-inside; Rehabilitation; Weight bearing;
D O I
10.1007/s12306-012-0209-0
中图分类号
学科分类号
摘要
The aim of this study was to review the published clinical outcomes of meniscal repair using the FasT-Fix device comparing standard rehabilitation program to an accelerated rehabilitation protocol. A review of the Medline database was performed involving searches for clinical outcomes of all-inside meniscus repair performed with the FasT-Fix device. Eight studies were identified for inclusion. On the basis of the clinical outcomes of these studies, there appears to be no notable difference between an accelerated rehabilitation regimen with full weight bearing allowed as soon as tolerated and a standard postoperative rehabilitation program. Failure rate was 13 % for patients following an accelerated rehabilitation regimen, and 10 % for standard protocol. Accelerated rehabilitation after all-inside meniscal repair using the FasT-Fix device appears to be safe, and the incidence of retears is in line with those reported for standard rehabilitation protocol.
引用
收藏
页码:149 / 154
页数:5
相关论文
共 50 条
  • [41] Comparison of All-Inside Meniscal Repair Devices with Matched Inside-Out Suture Repair
    Rosso, Claudio
    Kovtun, Konstantin
    Nazarian, Ara
    DeAngelis, Joseph P.
    Ramappa, Arun
    SWISS MEDICAL WEEKLY, 2011, 141 : 30S - 30S
  • [42] Biomechanical evaluation of meniscal repair systems - A comparison of the Meniscal Viper Repair System, the vertical mattress FasT-Fix device, and vertical mattress ethibond sutures
    Chang, HC
    Nyland, J
    Caborn, DNM
    Burden, R
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (12): : 1846 - 1852
  • [43] Long-term outcome after all-inside meniscal repair using the RapidLoc system
    Solheim, Eirik
    Hegna, Janne
    Inderhaug, Eivind
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (05) : 1495 - 1500
  • [44] Long-term outcome after all-inside meniscal repair using the RapidLoc system
    Eirik Solheim
    Janne Hegna
    Eivind Inderhaug
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 1495 - 1500
  • [45] An anatomic evaluation of T-Fix suture device placement for arthroscopic all-inside meniscal repair
    Coen, MJ
    Caborn, DNM
    Urban, W
    Nyland, J
    Johnson, DL
    ARTHROSCOPY, 1999, 15 (03): : 275 - 280
  • [46] A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus
    Kocabey, Y
    Chang, HC
    Brand, JC
    Nawab, A
    Nyland, J
    Caborn, DNM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (04): : 406 - 413
  • [47] A Comparison of All-inside and Inside-out Meniscal Repair in Elite Athletes
    Borque, Kyle A.
    Laughlin, Mitzi S.
    Webster, Emily
    Jones, Mary
    Pinheiro, Vitor Hugo
    Williams, Andy
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (03): : 579 - 584
  • [48] Arthroscopic all-inside meniscal repair-Does the meniscus heal?
    Hoffelner, Thomas
    Resch, Herbert
    Forstner, Rosemarie
    Michael, Mayer
    Minnich, Bernd
    Tauber, Mark
    SKELETAL RADIOLOGY, 2011, 40 (02) : 181 - 187
  • [49] All-inside meniscal repair devices - An experimental study in the goat model
    Miller, MD
    Kline, AJ
    Jepsen, KG
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (04): : 858 - 862
  • [50] Pullout repair of a medial meniscus posterior root tear using a FasT-Fix® all-inside suture technique
    Kodama, Y.
    Furumatsu, T.
    Fujii, M.
    Tanaka, T.
    Miyazawa, S.
    Ozaki, T.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (07) : 951 - 954