High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation

被引:0
|
作者
Li Lin
Peng Hu
Xin Tong
Shuai Na
Rui Cao
Xiaoyun Yuan
David C. Garrett
Junhui Shi
Konstantin Maslov
Lihong V. Wang
机构
[1] Andrew and Peggy Cherng Department of Medical Engineering,Caltech Optical Imaging Laboratory
[2] California Institute of Technology,Department of Electronic Engineering
[3] Tsinghua University,Zhejiang Lab
[4] Haidian District,undefined
[5] China Artificial Intelligence Town,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Photoacoustic computed tomography (PACT) has generated increasing interest for uses in preclinical research and clinical translation. However, the imaging depth, speed, and quality of existing PACT systems have previously limited the potential applications of this technology. To overcome these issues, we developed a three-dimensional photoacoustic computed tomography (3D-PACT) system that features large imaging depth, scalable field of view with isotropic spatial resolution, high imaging speed, and superior image quality. 3D-PACT allows for multipurpose imaging to reveal detailed angiographic information in biological tissues ranging from the rodent brain to the human breast. In the rat brain, we visualize whole brain vasculatures and hemodynamics. In the human breast, an in vivo imaging depth of 4 cm is achieved by scanning the breast within a single breath hold of 10 s. Here, we introduce the 3D-PACT system to provide a unique tool for preclinical research and an appealing prototype for clinical translation.
引用
收藏
相关论文
共 50 条
  • [21] Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography
    Wojtkowski, M
    Srinivasan, V
    Fujimoto, JG
    Ko, T
    Schuman, JS
    Kowalczyk, A
    Duker, JS
    OPHTHALMOLOGY, 2005, 112 (10) : 1734 - 1746
  • [22] Mapping retinal thickness and macular edema by high-speed three-dimensional optical coherence tomography
    Zhou, QY
    Trost, PK
    Lo, PW
    Hitzenberger, CK
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 119 - 125
  • [23] Recent advances toward preclinical and clinical translation of photoacoustic tomography: a review
    Upputuri, Paul Kumar
    Pramanik, Manojit
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (04)
  • [24] Rainbow three-dimensional camera: New concept of high-speed three-dimensional vision systems
    Geng, ZJ
    OPTICAL ENGINEERING, 1996, 35 (02) : 376 - 383
  • [25] Clinical Images: Three-dimensional computed tomography imaging of tophaceous gout
    Dalbeth, Nicola
    Clark, Barnaby
    Gregory, Kate
    Sheehan, Timothy
    McQueen, Fiona
    ARTHRITIS AND RHEUMATISM, 2007, 56 (01): : 29 - 29
  • [26] A survey of computational frameworks for solving the acoustic inverse problem in three-dimensional photoacoustic computed tomography
    Poudel, Joemini
    Lou, Yang
    Anastasio, Mark A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14):
  • [27] Development of a High-Speed Three-Dimensional Flow Visualization Technique
    Thurow, Brian S.
    Lynch, Kyle P.
    AIAA JOURNAL, 2009, 47 (12) : 2857 - 2865
  • [28] Three-dimensional imaging, measurement, and inspection of high-speed processes
    Ginzburg, V
    THREE-DIMENSIONAL IMAGING, OPTICAL METROLOGY, AND INSPECTION V, 1999, 3835 : 147 - 156
  • [29] High-speed, three-dimensional kinematic analysis of the normal wrist
    Patterson, RM
    Nicodemus, CL
    Viegas, SF
    Elder, KW
    Rosenblatt, J
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (03): : 446 - 453
  • [30] Computed tomography for high-speed rotation object
    Chen, Defeng
    Li, Hongwei
    Wang, Qian
    Zhang, Peng
    Zhu, Yining
    OPTICS EXPRESS, 2015, 23 (10): : 13423 - 13442