Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

被引:0
|
作者
Jan D Schmitto
Philipp Ortmann
Aron F Popov
Kasim O Coskun
Hanna Schotola
Martin Friedrich
Christoph H Wiese
Christian Sohns
Suyog A Mokashi
Vassilios N Didilis
Friedrich A Schoendube
机构
[1] Georg-August-University of Goettingen,Department of Thoracic
[2] Harvard Medical School,, Cardiac
[3] Georg-August-University of Goettingen, and Vascular Surgery
[4] Georg-August-University of Goettingen,Division of Cardiac Surgery, Brigham and Women's Hospital
关键词
Aortic Valve; Aortic Valve Replacement; Mitral Valve Disease; Aortic Valve Regurgitation; Aortic Ascendens;
D O I
暂无
中图分类号
学科分类号
摘要
We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic - no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial operation, we performed a Bentall-Procedure to treat an aortic ascendens aneurysm with diameters of 6.0 × 6.5 cm: we explanted the old Starr-Edwards-aortic-caged-ball-valve-prosthesis and replaced the ascending aorta with a 29 mm St.Jude Medical aortic-valve-composite-graft and re-implanted the coronary arteries.
引用
收藏
相关论文
共 50 条
  • [31] DISCUSSION OF AORTIC VALVE REPLACEMENT WITH A STARR-EDWARDS PROSTHESIS
    DUVOISIN, GE
    [J]. ARCHIVES OF SURGERY, 1969, 99 (06) : 689 - &
  • [32] FIXATION OF AORTIC BALL VALVE PROSTHEESIS (STARR-EDWARDS)
    BJORK, VO
    HULTQUIST, G
    [J]. THORAX, 1966, 21 (06) : 529 - +
  • [33] PHONOCARDIOGRAPHIC STUDY OF STARR-EDWARDS MITRAL BALL VALVE PROSTHESIS
    CANO, M
    DANESCU, C
    MSELLATI, H
    VERNANT, P
    [J]. COEUR, 1978, 9 (01): : 109 - 131
  • [34] Aortic ball-valve prosthesis after 38 years
    Litwak, RS
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (03): : 1131 - 1131
  • [35] LATE THROMBOSIS OF STARR-EDWARDS TRICUSPID BALL VALVE PROSTHESIS
    SUWANSIRIKUL, S
    GLASSMAN, E
    RAIA, F
    SPENCER, FC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (06): : 737 - 740
  • [36] AORTIC VALVE REPLACEMENT - RESULTS IN 108 PATIENTS WITH STARR-EDWARDS METALLIC BALL PROSTHESIS
    SANOUDOS, GM
    SPENCER, FC
    WALLSH, E
    [J]. CIRCULATION, 1971, 44 (04) : 221 - &
  • [37] LATE RESULTS OF AORTIC VALVE REPLACEMENT WITH STARR-EDWARDS PROSTHESIS
    MORGANS, CM
    BARRITT, DW
    BELSEY, RH
    KEEN, G
    WENSLEY, R
    [J]. BRITISH HEART JOURNAL, 1970, 32 (06): : 812 - &
  • [38] Structural Valve Deterioration in a Starr-Edwards Mitral Caged-Disk Valve Prosthesis
    Aoyagi, Shigeaki
    Tayama, Kei-ichiro
    Okazaki, Teiji
    Shintani, Yusuke
    Kono, Michitaka
    Wada, Kumiko
    Kosuga, Ken-ichi
    Mori, Ryusuke
    Tanaka, Hiroyuki
    [J]. CIRCULATION JOURNAL, 2013, 77 (01) : 105 - 108
  • [39] PERIPHERAL EMBOLIZATION OF A STRUT 12 YEARS AFTER AORTIC-VALVE REPLACEMENT WITH A STARR-EDWARDS VALVE PROSTHESIS
    SCHELD, HH
    SCHLEPPER, M
    MULCH, J
    GORLACH, G
    HOGE, R
    HEHRLEIN, FW
    [J]. HERZ KREISLAUF, 1983, 15 (05): : 240 - 243
  • [40] Starr-Edwards aortic valve strut fracture with ball embolus
    Meholic, AJ
    Jaksha, MM
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (01) : 91 - 92