On the Causes of Fractures of Reinforcing Ropes of the Protective Shells of Power-Generating Units of Nuclear Power Plants

被引:0
|
作者
V. M. Torop
M. D. Rabkina
O. O. Shtofel’
V. V. Usov
N. M. Shkatulyak
O. S. Savchuk
机构
[1] E. Paton Institute of Electric Welding,
[2] Ukrainian National Academy of Sciences,undefined
[3] Ushyns’kyi South-Ukrainian National Pedagogical University,undefined
来源
Materials Science | 2018年 / 54卷
关键词
reinforcing ropes; fractures; fractography; mechanical tests; fractal dimension; damage;
D O I
暂无
中图分类号
学科分类号
摘要
We determine possible causes of premature failures of typical reinforcing ropes of the protective shells of nuclear power plants with regard for the mechanical parameters of wires, the character of damages to their surfaces, and the fractal dimensions of the fracture surfaces. It is shown that brittle fracture is realized for lower levels of plasticity of the metal of wires and lower degrees of its damage. This type of fracture is characterized by a higher fractal dimension of the fracture surfaces.
引用
收藏
页码:240 / 249
页数:9
相关论文
共 50 条
  • [21] Steam-turbine plants for power-generating units of new generation
    Troyanovskij, B.M.
    Ogurtsov, A.P.
    Koryagin, A.V.
    1996, Mezhdunarodnaya Kniga, Moscow, Russian Federation
  • [22] Development and adoption of measures for increasing the safety of power-generating units of nuclear power plants with RBMK reactors in 1986-2005
    Vasilevskii, V. P.
    Mikhailov, M. N.
    Petrov, A. A.
    Rozhdestvenskii, M. I.
    Cherkashov, Yu. M.
    ATOMIC ENERGY, 2006, 100 (04) : 295 - 301
  • [23] VBER-300 reactor system and power-generating units for regional nuclear power production
    Kostin, V. I.
    Petrunin, V. V.
    Samoilov, O. B.
    Kurachenkov, A. V.
    ATOMIC ENERGY, 2007, 102 (01) : 36 - 41
  • [24] Several conceptual questions on lifetime management of Russian power-generating units at nuclear power stations
    Savchenko, V.A.
    2000, IAPC Nauka/Interperiodica (47)
  • [25] Improvement of thermal schemes for power-generating units
    Efimochkin, G.I.
    Shmukler, B.I.
    Avrutskii, G.D.
    Thermal Engineering, 2000, 47 (04) : 333 - 341
  • [26] PROTECTIVE COATINGS FOR NUCLEAR-POWER GENERATING PLANTS
    LICHTENSTEIN, J
    MATERIALS PERFORMANCE, 1981, 20 (08) : 48 - 48
  • [27] Possibility of burning irradiated graphite from decommissioned nuclear power-generating units
    V. V. Frolov
    A. V. Kryuchkov
    Yu. N. Kuznetsov
    V. A. Moskin
    Yu. V. Pankrat’ev
    A. A. Romenkov
    Atomic Energy, 2004, 97 (5) : 781 - 784
  • [28] Possibility of burning irradiated graphite from decommissioned nuclear power-generating units
    V. V. Frolov
    A. V. Kryuchkov
    Yu. N. Kuznetsov
    V. A. Moskin
    Yu. V. Pankrat’ev
    A. A. Romenkov
    Atomic Energy, 2004, 97 : 781 - 784
  • [29] Choice of the unit power-generating capacity of a nuclear power plant
    P. N. Alekseev
    V. M. Mordashev
    A. A. Proshkin
    V. A. Stukalov
    S. A. Subbotin
    V. F. Tsibul’skii
    Yu. F. Chernilin
    Atomic Energy, 2008, 105 : 309 - 315
  • [30] Possibility of burning irradiated graphite from decommissioned nuclear power-generating units
    Frolov, VV
    Kryuchkov, AV
    Kuznetsov, YN
    Moskin, VA
    Pankrat'ev, YV
    Romenkov, AA
    ATOMIC ENERGY, 2004, 97 (05) : 781 - 784