Comprehensive assessment of image quality in synthetic and digital mammography: a quantitative comparison

被引:0
|
作者
Patrizio Barca
Rocco Lamastra
Giacomo Aringhieri
Raffaele Maria Tucciariello
Antonio Traino
Maria Evelina Fantacci
机构
[1] University of Pisa,Department of Physics
[2] INFN,Department of Translational Research and of New Technologies in Medicine and Surgery
[3] Pisa Section,Unit of Medical Physics
[4] University of Pisa,undefined
[5] Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”,undefined
关键词
Synthetic mammography; Digital mammography; Image quality; Digital breast tomosynthesis; Contrast-detail analysis; C-view™;
D O I
暂无
中图分类号
学科分类号
摘要
Recent advances in digital breast tomosynthesis (DBT) technology were focused on the reconstruction of 2D “Synthesized Mammograms” (SMs) from DBT dataset. The introduction of SMs could avoid an additional digital mammography (DM) which is often required in complement to DBT examinations. Therefore, breast absorbed dose and compression time can be significantly reduced in DBT+SM procedures with respect to DBT+DM modality. However, to date, a limited number of studies have objectively characterised the image quality of SMs with respect to DM images. Therefore, the aim of this phantom study was to comprehensively compare SMs and DM images in terms of several image quality parameters. A Selenia Dimensions system (Hologic, Bedford, Mass, USA) was employed in this work. Five different phantoms were adopted to study noise, contrast and spatial resolution properties of the images. Specifically, noise power spectrum (NPS), maps of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), modulation transfer function (MTF) and contrast-detail (CD) thresholds were evaluated both for SM and DM modalities. SMs were characterised by different texture, noise and SNR spatial distribution properties with respect to DM images. Additionally, while in some conditions SM provides higher CNR than DM, lower overall performances in terms spatial resolution and CD curves were found in comparison to DM images. Therefore, given the great benefits of SMs in terms of dose and compression time saving, further clinical investigations on SMs image quality properties could be of practical interest to integrate our findings.
引用
收藏
页码:1141 / 1152
页数:11
相关论文
共 50 条
  • [1] Comprehensive assessment of image quality in synthetic and digital mammography: a quantitative comparison
    Barca, Patrizio
    Lamastra, Rocco
    Aringhieri, Giacomo
    Tucciariello, Raffaele Maria
    Traino, Antonio
    Fantacci, Maria Evelina
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1141 - 1152
  • [2] Quantitative assessment of microcalcification cluster image quality in digital breast tomosynthesis, 2-dimensional and synthetic mammography
    Andreas E. Petropoulos
    Spyros G. Skiadopoulos
    Anna N. Karahaliou
    Gerasimos A. T. Messaris
    Nikolaos S. Arikidis
    Lena I. Costaridou
    Medical & Biological Engineering & Computing, 2020, 58 : 187 - 209
  • [3] Quantitative assessment of microcalcification cluster image quality in digital breast tomosynthesis, 2-dimensional and synthetic mammography
    Petropoulos, Andreas E.
    Skiadopoulos, Spyros G.
    Karahaliou, Anna N.
    Messaris, Gerasimos A. T.
    Arikidis, Nikolaos S.
    Costaridou, Lena I.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (01) : 187 - 209
  • [4] Evaluation and Comparison of Image Quality Figures for Digital Mammography
    Tsai, H. Y.
    Liu, H. L.
    Hwang, Y. S.
    Chen, C. C.
    MEDICAL PHYSICS, 2009, 36 (06) : 2451 - +
  • [5] Image Quality and Radiation Dose Assessment of a Digital Mammography System
    Isa, N. M.
    Hassan, W. M. S. W.
    Abdullah, W. A. K. W.
    Othman, F.
    Ramli, A. A. M.
    PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 : 397 - +
  • [6] Comparison of image quality in contact and magnification modes in digital mammography
    Liu, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2014 - 2014
  • [7] A comparative study of physical image quality in digital and synthetic mammography from commercially available mammography systems
    Baldelli, Paola
    Bertolini, Marco
    Contillo, Adriano
    Della Gala, Giuseppe
    Golinelli, Paola
    Pagan, Laura
    Rivetti, Stefano
    Taibi, Angelo
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16):
  • [8] Dose sensitivity of three methods of image quality assessment in digital mammography
    Hummel, Johann
    Kaar, Marcus
    Hoffmann, Rainer
    Kaldarar, Heinrich
    Semturs, Friedrich
    Homolka, Peter
    Figl, Michael
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [9] Quantitative analysis of radiation dosage and image quality between digital breast tomosynthesis (DBT) with two-dimensional synthetic mammography and full-field digital mammography (FFDM)
    Choi, Yoonmi
    Woo, Ok-hee
    Shin, Hye-sun
    Cho, Kyu Ran
    Seo, Bo Kyoung
    Choi, Ga-Young
    CLINICAL IMAGING, 2019, 55 : 12 - 17
  • [10] Improved image quality in digital mammography with image processing
    Baydush, AH
    Floyd, CE
    MEDICAL PHYSICS, 2000, 27 (07) : 1503 - 1508