Quantitative analysis of radiation dosage and image quality between digital breast tomosynthesis (DBT) with two-dimensional synthetic mammography and full-field digital mammography (FFDM)

被引:13
|
作者
Choi, Yoonmi [1 ]
Woo, Ok-hee [1 ]
Shin, Hye-sun [1 ]
Cho, Kyu Ran [1 ]
Seo, Bo Kyoung [1 ]
Choi, Ga-Young [1 ]
机构
[1] Korea Univ, Dept Radiol, Guro Hosp, 148 Gurodong Ro, Seoul 08308, South Korea
关键词
Digital breast tomosynthesis; Full-field digital mammography; 2-Dimensional synthetic mammography; Radimetrics; Image quality; Radiation dose;
D O I
10.1016/j.clinimag.2019.01.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Currently in diagnostic setting for breast cancer, FFDM and DBT are performed conjunctively. However, performing two imaging modalities may increase radiation exposure by double. Two-dimensional reconstructed images created from DBT with 2DSM, has a potential to replace conventional FFDM in concerning both radiation dosage and image quality. With increasing concerns for individual radiation exposure, studies analyzing radiation dosage in breast imaging modalities are needed. This study compared radiation dosage and image quality between DBT + 2DSM versus FFDM. Methods and materials: 374 patients (mean age 52 years) who underwent both DBT and FFDM were retrospectively reviewed. Radiation dosage data were obtained by radiation dosage scoring and monitoring program Radimetrics (Bayer HealthCare, Whippany, NJ). Entrance dose and mean glandular doses in each breast were obtained for both modalities. To compare image quality of DBT + 2DSM and FFDM, a 5-point scoring system for lesion clarity was assessed. The parameters of radiation dosage (entrance dose, mean glandular dose) and image quality (lesion clarity scoring) were compared. Results: For entrance dose, DBT had lower mean dosage (14.8 mGy) compared with FFDM (21.8 mGy, p-value < 0.0001). Mean glandular doses for both breasts were lower in DBT (Left 1.74, Right 2.1) compared with FFDM (Left 2.85, Right 2.74, p-value < 0.0001). Lesion clarity score was higher in DBT with 2DSM (mean score 4.03) compared with FFDM (3.82, p-value < 0.0001). Conclusion: DBT showed lower radiation entrance dose and mean glandular doses to both breasts compared with FFDM. DBT + 2DSM had better image quality than FFDM, suggesting that DBT with 2DSM has potential as an alternative to FFDM.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 50 条
  • [1] Comparison of radiation doses between diagnostic full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT): a clinical study
    Asbeutah, Akram M.
    AlMajran, Abdullah A.
    Brindhaban, Ajit
    Asbeutah, Saad A.
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (03) : 185 - 192
  • [2] Digital full-field mammography (FFDM) versus digital breast tomosynthesis (DBT) Which system increases the quality of preparation radiography?
    Urban, H.
    Bauerschmitz, G. J.
    Gallwas, J.
    Wienbeck, S.
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 2022, 82 (10) : E175 - E175
  • [3] Local diagnostic reference levels (LDRLs) for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) procedures in Morocco
    Talbi, Mohammed
    El Mansouri, M'hamed
    Nhila, Oussama
    Tahiri, Zakaria
    Eddaoui, Khalida
    Khalis, Mohammed
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (02) : 242 - 247
  • [4] A comparison of full-field digital mammography (FFDM) with digital breast tomosynthesis (DBT) in the detection of microcalcifications by correlating mammographic and pathologic findings
    Farghadani, Maryam
    Ghadiri-faraz, Bahar
    Riahinezhad, Maryam
    Sarami, Sahar
    [J]. IMMUNOPATHOLOGIA PERSA, 2024, 10 (02):
  • [5] Comparative Benefit-to-Radiation Risk Ratio of Molecular Breast Imaging, Two-Dimensional Full-Field Digital Mammography with and without Tomosynthesis, and Synthetic Mammography with Tomosynthesis
    Brown, Matthew
    Covington, Matthew F.
    [J]. RADIOLOGY-IMAGING CANCER, 2019, 1 (01):
  • [6] Comparison between two-dimensional synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for the detection of T1 breast cancer
    Ji Soo Choi
    Boo-Kyung Han
    Eun Young Ko
    Eun Sook Ko
    Soo Yeon Hahn
    Jung Hee Shin
    Min Jung Kim
    [J]. European Radiology, 2016, 26 : 2538 - 2546
  • [7] Comparison between two-dimensional synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for the detection of T1 breast cancer
    Choi, Ji Soo
    Han, Boo-Kyung
    Ko, Eun Young
    Ko, Eun Sook
    Hahn, Soo Yeon
    Shin, Jung Hee
    Kim, Min Jung
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (08) : 2538 - 2546
  • [8] Comparison of the diagnostic performance of synthesized two-dimensional mammography and full-field digital mammography alone or in combination with digital breast tomosynthesis
    You, Chao
    Zhang, Yunyan
    Gu, Yajia
    Xiao, Qin
    Liu, Guangyu
    Shen, Xigang
    Yang, Wentao
    Peng, Weijun
    [J]. BREAST CANCER, 2020, 27 (01) : 47 - 53
  • [9] Comparison of the diagnostic performance of synthesized two-dimensional mammography and full-field digital mammography alone or in combination with digital breast tomosynthesis
    Chao You
    Yunyan Zhang
    Yajia Gu
    Qin Xiao
    Guangyu Liu
    Xigang Shen
    Wentao Yang
    Weijun Peng
    [J]. Breast Cancer, 2020, 27 : 47 - 53
  • [10] Comparative analysis between synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for breast cancer detection and visibility
    Murakami, Ryusuke
    Uchiyama, Nachiko
    Tani, Hitomi
    Yoshida, Tamiko
    Kumita, Shinichiro
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2020, 7