The effect of bone porosity on the shear strength of the bone–cement interface

被引:3
|
作者
Rouin Amirfeyz
Gordon Bannister
机构
[1] Southmead Hospital,Avon Orthopaedic Centre
[2] Southmead Hospital,Bristol Implant Research Centre, Avon Orthopaedic Centre
来源
关键词
Shear Strength; Cancellous Bone; Aseptic Loosening; Interface Shear Strength; Bone Slice;
D O I
暂无
中图分类号
学科分类号
摘要
This study investigated the relationship of bone porosity and bone–cement interface shear strength. One hundred forty-six samples were taken from the distal metaphysis of 20 bovine femora. After cementation, the shear strength of the bone–cement interface was tested. According to the porosity, the samples were divided into four groups. Group I (porosity <80%) had a median interface shear strength of 4.03 MPa, group II (80% ≤porosity <85%) 7.06 MPa, group III (85% ≤porosity <90%) 9.44 MPa, and group IV (porosity ≥90%) 14.85 MPa. The differences between the four groups were statistically significant. Greater porosity yielded a stronger bone–cement interface shear strength under the identical cementation technique. The optimum porosity of cancellous bone is more than 90% which can be found by reaming or drilling to deeper bone in cemented acetabular fixation.
引用
收藏
页码:843 / 846
页数:3
相关论文
共 50 条
  • [31] The effect of bone ingrowth depth on the tensile and shear strength of the implant-bone e-beam produced interface
    Tarala, M.
    Waanders, D.
    Biemond, J. E.
    Hannink, G.
    Janssen, D.
    Buma, P.
    Verdonschot, N.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2011, 22 (10) : 2339 - 2346
  • [32] STRENGTH OF ACRYLIC BONE CEMENTS AND ACRYLIC CEMENT STAINLESS STEEL INTERFACES .2. SHEAR-STRENGTH OF AN ACRYLIC CEMENT STAINLESS STEEL INTERFACE
    BEAUMONT, PWR
    PLUMPTON, B
    JOURNAL OF MATERIALS SCIENCE, 1977, 12 (09) : 1853 - 1856
  • [33] Experimental investigation of the effect of surface roughness on bone-cement-implant shear bond strength
    van Tol, Alexander Franciscus
    Tibballs, John E.
    Gjerdet, Nils Roar
    Ellison, Peter
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 28 : 254 - 262
  • [34] The effect of different cement insertion techniques on the bone-cement interface
    Horne, JG
    Bruce, W
    Devane, PA
    Teoh, HH
    JOURNAL OF ARTHROPLASTY, 2002, 17 (05): : 579 - 583
  • [35] Nondestructive Evaluation of Bone Cement and Bone Cement/Metal Interface Failure
    Browne, M.
    Jeffers, J. R. T.
    Saffari, N.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 92B (02) : 420 - 429
  • [36] Thermal analysis of bone cement polymerisation at the cement-bone interface
    Stanczyk, M
    van Rietbergen, B
    JOURNAL OF BIOMECHANICS, 2004, 37 (12) : 1803 - 1810
  • [37] EFFECT OF AN INVIVO ENVIRONMENT ON THE STRENGTH OF BONE-CEMENT
    ROSTOKER, W
    LEREIM, P
    GALANTE, JO
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (03): : 365 - 370
  • [38] The influence of cementing technique and blood on the strength of the bone-cement interface
    Bannister, G.C.
    Miles, A.W.
    Engineering in Medicine, 1988, 17 (03): : 131 - 133
  • [39] SHEAR-STRENGTH OF TRABECULAR BONE FROM THE FEMUR AND FACTORS AFFECTING THE CEMENT-BONE BOND
    HALAWA, MM
    LEE, AJC
    LING, RSM
    VANGALA, SS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1979, 61 (01): : 118 - 118
  • [40] Stress shielding in bone of a bone-cement interface
    Zhang, Qing-Hang
    Cossey, Andrew
    Tong, Jie
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (04) : 423 - 426