Optical path-length matrix method for estimating skin spectrum

被引:0
|
作者
Satoshi Yamamoto
Izumi Fujiwara
Midori Yamauchi
Norimichi Tsumura
Keiko Ogawa-Ochiai
机构
[1] Keio University,Center for Kampo Medicine, School of Medicine
[2] Chiba University,Graduate School of Advanced Integration Science
[3] Kanazawa University Hospital,Clinic of Japanese
来源
Optical Review | 2012年 / 19卷
关键词
Monte Carlo for multi-layered media; probabilistic histograms; optical path-length matrix; spectral reflectance; human skin; high-speed simulation;
D O I
暂无
中图分类号
学科分类号
摘要
In this article, we propose a new method—the optical path-length matrix method (OPLM)—as a faster alternative to the Monte Carlo for multi-layered media (MCML), which is often used to simulate the skin spectrum. Theoretically, peripheral oxygen saturation can be estimated by iterating MCML, but it is not a realistic strategy because it requires huge computation time. The optical path-length matrix is obtained as the probabilistic density histograms of the optical path length in skin using MCML, and once the matrix is obtained, skin spectral reflectance can be calculated by accumulating all combinations of elements in the matrix and by setting an absorption coefficient based on the Beer-Lambert law. The computational time of OPLM was approximately 26,000 times faster than that of MCML.
引用
收藏
页码:361 / 365
页数:4
相关论文
共 50 条
  • [41] ON THE COMPLEXITY OF FLOW PROBLEMS WITH PATH-LENGTH CONSTRAINTS
    KUZMIN, SL
    SOVIET JOURNAL OF COMPUTER AND SYSTEMS SCIENCES, 1985, 23 (06): : 57 - 64
  • [43] Path-length control in a interferometric QKD link
    Elliott, BB
    Pikalo, O
    Schlafer, J
    Troxel, G
    QUANTUM INFORMATION AND COMPUTATION, 2003, 5105 : 26 - 38
  • [44] AN ANATOMIC STUDY OF RETROBULBAR NEEDLE PATH-LENGTH
    KATSEV, DA
    DREWS, RC
    ROSE, BT
    OPHTHALMOLOGY, 1989, 96 (08) : 1221 - 1224
  • [45] Light path-length distributions within the retina
    Rodmell, Paul I.
    Crowe, John A.
    Gorman, Alastair
    Harvey, Andrew R.
    Muyo, Gonzalo
    Mordant, David J.
    McNaught, Andy I.
    Morgan, Stephen P.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (03)
  • [46] A KINETIC PARAMETER-ESTIMATION TECHNIQUE WITH LONG PATH-LENGTH SPECTROELECTROCHEMICAL METHOD
    WEI, WZ
    XIE, QJ
    YAO, SZ
    ELECTROCHIMICA ACTA, 1995, 40 (08) : 1057 - 1061
  • [47] General design method for ultralong optical path length multipass matrix cells
    Gai, Yiyun
    Li, Wenjin
    Yi, Kaihao
    Ou, Xue
    Huang, Zhaoyue
    Liu, Peng
    Zhou, Xin
    OPTICS EXPRESS, 2025, 33 (02): : 2728 - 2744
  • [48] Selectable microwave-frequency doubling and quadrupling via optical path-length tuning
    Maafa, M. R.
    Maywar, D. N.
    ELECTRONICS LETTERS, 2022, 58 (11) : 439 - 441
  • [50] Single-beam diode-laser technique for optical path-length measurements
    Carlisle, CB
    Warren, RE
    Riris, H
    APPLIED OPTICS, 1996, 35 (22): : 4349 - 4354