Characteristics of successful filtering blebs at 1 year after trabeculectomy using swept-source three-dimensional anterior segment optical coherence tomography

被引:0
|
作者
Akiko Narita
Yuki Morizane
Tomoe Miyake
Jiro Seguchi
Tetsuya Baba
Fumio Shiraga
机构
[1] Okayama Saiseikai General Hospital,Department of Ophthalmology
[2] Okayama University Graduate School of Medicine,Department of Ophthalmology
[3] Dentistry and Pharmaceutical Science,undefined
[4] Shirai Eye Hospital,undefined
来源
关键词
Glaucoma; Trabeculectomy; Filtering bleb; Anterior segment optical coherence tomography;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:253 / 259
页数:6
相关论文
共 50 条
  • [1] Characteristics of successful filtering blebs at 1 year after trabeculectomy using swept-source three-dimensional anterior segment optical coherence tomography
    Narita, Akiko
    Morizane, Yuki
    Miyake, Tomoe
    Seguchi, Jiro
    Baba, Tetsuya
    Shiraga, Fumio
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2017, 61 (03) : 253 - 259
  • [2] Three-dimensional anterior segment optical coherence tomography of filtering blebs after trabeculectomy
    Miura, Masahiro
    Kawana, Keisuke
    Iwasaki, Takuya
    Kiuchi, Takahiro
    Oshika, Tetsuro
    Mori, Hideki
    Yamanari, Masahiro
    Makita, Shuichi
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (03) : 193 - 196
  • [3] Characteristics of early filtering blebs that predict successful trabeculectomy identified via three-dimensional anterior segment optical coherence tomography
    Narita, Akiko
    Morizane, Yuki
    Miyake, Tomoe
    Seguchi, Jiro
    Baba, Tetsuya
    Shiraga, Fumio
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (06) : 796 - 801
  • [4] Evaluation of Successful and Failed Filtering Blebs after Trabeculectomy Using Anterior Segment Optical Coherence Tomography
    Tekin, Serek
    Seven, Erbil
    Batur, Muhammed
    Ozer, Muhammet Derda
    Yasar, Tekin
    [J]. JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (01): : 1 - 5
  • [5] Evaluation of glaucoma filtering blebs with a swept-source Optical Coherence Tomography
    Milla, Elena
    Zarranz-Ventura, Javier
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [6] Three-Dimensional Morphometric Analysis of the Iris by Swept-Source Anterior Segment Optical Coherence Tomography in a Caucasian Population
    Invernizzi, Alessandro
    Giardini, Piero
    Cigada, Mario
    Viola, Francesco
    Staurenghi, Giovanni
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) : 4796 - 4801
  • [7] Imaging of trabeculectomy blebs using anterior segment optical coherence tomography
    Singh, Mandeep
    Chew, Paul T. K.
    Friedman, David S.
    Nolan, Winifred P.
    See, Jovina L.
    Smith, Scott D.
    Zheng, Ce
    Foster, Paul J.
    Aung, Tin
    [J]. OPHTHALMOLOGY, 2007, 114 (01) : 47 - 53
  • [8] Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
    Higashiyama, Tomoaki
    Iwasa, Maki
    Ohji, Masahito
    [J]. PLOS ONE, 2017, 12 (08):
  • [9] Clinical examinations of anterior eye segments by three-dimensional swept-source optical coherence tomography
    Yasuno, Yoshiaki
    Yamanari, Masahiro
    Mori, Hideki
    Kawana, Keisuke
    Watanabe, Yuji
    Miura, Masahiro
    Miyazawa, Arata
    Oshika, Tetsuro
    Yatagai, Toyohiko
    [J]. OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [10] Morphology of Trabeculectomy Filtering Blebs using Anterior Segment Optical Coherence Tomography: A Comparison of Two Methods
    Proenca, Rita Pinto
    Ferreira, Joana
    Cunha, Joao Paulo
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PHOTONICS, OPTICS AND LASER TECHNOLOGY (PHOTOPTICS), 2017, : 414 - 419