Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography

被引:13
|
作者
Higashiyama, Tomoaki [1 ]
Iwasa, Maki [1 ]
Ohji, Masahito [1 ]
机构
[1] Shiga Univ Med Sci, Dept Ophthalmol, Otsu, Shiga, Japan
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
INTERFEROMETRY; CYCLOPENTOLATE; REPEATABILITY; ATROPINE; REFRACTION; AGREEMENT; CHILDREN;
D O I
10.1371/journal.pone.0183378
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to investigate changes in the anterior segment of the eye after cycloplegia. A biometer combined with swept-source optical coherence tomography (SSOCT) was used for measurements. Patients with strabismus or amblyopia who underwent cycloplegia were included. The axial length, central corneal thickness, anterior chamber depth, and lens thickness were measured with the biometer-SSOCT system before and after cycloplegia. Altogether, 10 eyes of 10 patients (mean age 7.20 +/- 3.08 years, range 4-14 years) were evaluated. The mean measurements before cycloplegia were 22.75 +/- 0.96 mm axial length, 516 +/- 33 mu m central corneal thickness, 3.40 +/- 0.21 mm anterior chamber depth, and 3.77 +/- 0.26 mm lens thickness. The corresponding values after cycloplegia were 22.75 +/- 0.95 mm, 519 +/- 34 mu m, 3.68 +/- 0.16 mm, and 3.42 +/- 0.20 mm, respectively. The mean lens thickness had significantly decreased (P < 0.001) after cycloplegia, and the mean anterior chamber depth had significantly increased (P < 0.001). The means of the axial length (P = 0.66) and central corneal thickness (P = 0.17) had not changed significantly. The change in lens thickness was significantly correlated with the change in anterior chamber depth (r = -0.73, P = 0.02). The new biometer-SSOCT combination proved useful for accurately detecting changes in the anterior segment of the eye after cycloplegia in pediatric patients. The biometer's measurements indicated increased anterior chamber depth and decreased lens thickness after cycloplegia. The anterior chamber depth increased relative to the decrease in lens thickness.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug-Placido tomographer
    Lu, Weicong
    Li, Yue
    Savini, Giacomo
    Song, Benhao
    Hu, Qingjie
    Wang, Qinmei
    Bao, Fangjun
    Huang, Jinhai
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03): : 298 - 304
  • [2] Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry
    Hoffer, Kenneth J.
    Hoffmann, Peter C.
    Savini, Giacomo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1165 - 1172
  • [3] Comparison of a new biometer using swept-source optical coherence tomography and a conventional biometer using partial coherence interferometry
    Higashiyama, Tomoaki
    Mori, Hazuki
    Nakajima, Fumi
    Ohji, Masahito
    [J]. PLOS ONE, 2018, 13 (04):
  • [4] Anterior Segment Angiography with 1050 nm Swept-Source Optical Coherence Tomography
    Li, Yan
    Lu, Chen D.
    Jia, Yali
    Lee, ByungKun
    Kraus, Martin F.
    Hornegger, Joachim
    Fujimoto, James G.
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [5] Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence Tomography
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Yamagami, Satoru
    Amano, Shiro
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 620 - 624
  • [6] Polarization sensitive corneal and anterior segment swept-source optical coherence tomography
    Lim, Yiheng
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    [J]. OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [7] Dynamic imaging of accommodation by swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Ruggeri, Marco
    Protti, Alessandra
    Lead, Rosachiara
    Gandolfi, Stefano A.
    Macaluso, Claudio
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03): : 501 - 510
  • [8] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    [J]. EYE AND VISION, 2023, 10 (01)
  • [9] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Alberto Domínguez-Vicent
    Abinaya Priya Venkataraman
    Amanda Dalin
    Rune Brautaset
    Robert Montés-Micó
    [J]. Eye and Vision, 10
  • [10] Role of swept-source anterior segment optical coherence tomography in imaging pediatric cataract
    Bhardwaj, Anand
    Kaur, Savleen
    Sukhija, Jaspreet
    Gupta, Parul Chawla
    Ram, Jagat
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 2132 - 2138