Development and validation of thin-layer chromatography and high-performance thin-layer chromatography methods for the simultaneous determination of linagliptin and empagliflozin in their co-formulated dosage form

被引:0
|
作者
Mohamed Rizk
Ali K. Attia
Heba Y. Mohamed
Mona S. Elshahed
机构
[1] Helwan University,Department of Analytical Chemistry, Faculty of Pharmacy
[2] National Organization for Drug Control and Research (NODCAR),Chemistry Department, College of Sciences
[3] Majmaah University,undefined
关键词
Linagliptin; Empagliflozin; Thin-layer chromatography; High-performance thin-layer chromatography; Co-formulated pharmaceutical preparations;
D O I
暂无
中图分类号
学科分类号
摘要
A sensitive, simple and validated thin-layer chromatography (TLC) method (method A) and a high-performance thin-layer chromatography (HPTLC) method (method B) have been developed for the simultaneous determination of linagliptin (LNG) and empagliflozin (EMP) in laboratory prepared mixtures and in their co-formulated pharmaceutical preparations. Chromatographic separation has been done using TLC silica gel 60 F254 aluminum plates (20 cm × 10 cm, 0.25 mm thickness) and the mobile phase consisting of chloroform‒methanol‒ammonia (33%) (9:1:0.1, V/V) for method A. Chromatographic separation in method B was carried out using HPTLC nano-silica gel 60 F254 glass plates (10 cm × 10 cm, 0.1 mm thickness) and the mobile phase consisting of chloroform‒methanol‒ammonia (25%) (10:1:0.1, V/V). The optimized chromatographic conditions gave good peak shapes with good resolutions at acceptable RF values of 0.25 ± 0.01 for EMP, 0.56 ± 0.01 for LNG in method A, 0.31 ± 0.01 for EMP and 0.71 ± 0.01 for LNG in method B. Both methods were validated for linearity, accuracy, precision and specificity. The calibration plots were linear over a concentration range of 0.4‒10 µg/band with a correlation coefficient of 0.9998 for EMP and 0.2‒5.0 µg/band with a correlation coefficient of 0.9998 for LNG in method A. In method B, the linear range for calibration was 0.1‒5.0 µg/band with a correlation coefficient of 0.9999 for EMP and 0.05‒2.5 µg/band with a correlation coefficient of 0.9999 for LNG. The optimized methods were successfully applied for the determination of the studied drugs in laboratory prepared mixtures and in their co-formulated pharmaceutical preparations with no significant difference observed upon statistical comparison between the proposed and reported methods.
引用
收藏
页码:647 / 661
页数:14
相关论文
共 50 条
  • [41] Development and Validation of Simplified High-Performance Thin-Layer Chromatography Densitometric Methods for the Determination of Sulfalene, Sulfadoxine, and Pyrimethamine
    Mwalwisi, Yonah H.
    Hoellein, Ludwig
    Shewiyo, Danstan H.
    Holzgrabe, Ulrike
    Kaale, Eliangiringa
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2018, 31 (04) : 290 - 296
  • [42] Stability-Indicating High-Performance Column Liquid Chromatography and High-Performance Thin-Layer Chromatography Methods for the Determination of Olopatadine Hydrochloride in Tablet Dosage Form
    Varghese, Susheel John
    Kumar, A. Manikanta
    Ravi, Thengungal Kochupappy
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (06) : 1815 - 1820
  • [43] SIMULTANEOUS DETERMINATION OF ANTI-ARRHYTHMIA DRUGS BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    LEE, KY
    NUROK, D
    ZLATKIS, A
    KARMEN, A
    JOURNAL OF CHROMATOGRAPHY, 1978, 158 (OCT): : 403 - 410
  • [44] Simultaneous determination of diloxanide furoate and tinidazole in tablets by high-performance thin-layer chromatography
    Argekar, AP
    Powar, SG
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 1999, 12 (06) : 452 - 455
  • [45] Determination of Rosuvastatin and Ezetimibe in a Combined Tablet Dosage Form Using High-Performance Column Liquid Chromatography and High-Performance Thin-Layer Chromatography
    Varghese, Susheel John
    Ravi, Thengungal Kochupappy
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1222 - 1227
  • [46] SEPARATION OF LIPIDS BY NEW THIN-LAYER CHROMATOGRAPHY AND OVERPRESSURED THIN-LAYER CHROMATOGRAPHY METHODS
    PUCSOK, J
    KOVACS, L
    ZALKA, A
    DOBO, R
    CLINICAL BIOCHEMISTRY, 1988, 21 (02) : 81 - 85
  • [47] Validated high-performance thin-layer chromatography method for determination of trigonelline in herbal extract and pharmaceutical dosage form
    Chopra, Shruti
    Ahmad, Farhan J.
    Khar, Roop K.
    Motwani, Sanjay K.
    Mahdi, Saiqa
    Iqbal, Zeenat
    Talegaonkar, Sushma
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 46 - 51
  • [48] NEW METHODS OF QUANTITATION IN THIN-LAYER CHROMATOGRAPHY - TUBULAR THIN-LAYER CHROMATOGRAPHY [TTLC]
    MANGOLD, HK
    MUKHERJEE, KD
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1975, 13 (09) : 398 - 402
  • [49] THIN-LAYER CHROMATOGRAPHY AND HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY OF [H-3] METABOLITES OF 20-HYDROXYECDYSONE
    WILSON, ID
    LAFONT, R
    INSECT BIOCHEMISTRY, 1986, 16 (01): : 33 - 40
  • [50] Ganglioside analysis by high-performance thin-layer chromatography
    Yu, RK
    Ariga, T
    SPHINGOLIPID METABOLISM AND CELL SIGNALING, PT B, 2000, 312 : 115 - 134