Two-dimensional breast dosimetry improved using three-dimensional breast image data

被引:8
|
作者
Boone J.M. [1 ]
Hernandez A.M. [1 ]
Seibert J.A. [1 ]
机构
[1] Department of Radiology, UC Davis Medical Center, University of California Davis, Sacramento, 95817, CA
基金
美国国家卫生研究院;
关键词
Breast CT; Breast dosimetry; Mammography; Mean glandular dose; Monte Carlo;
D O I
10.1007/s12194-017-0404-7
中图分类号
学科分类号
摘要
Conventional mammographic dosimetry has been developed over the past 40 years. Prior to the availability of high-resolution three-dimensional breast images, certain assumptions about breast anatomy were required. These assumptions were based on the information evident on two-dimensional mammograms; they included assumptions of thick skin, a uniform mixture of glandular and adipose tissue, and a median breast density of 50%. Recently, the availability of high-resolution breast CT studies has provided more accurate data about breast anatomy, and this, in turn, has provided the opportunity to update mammographic dosimetry. Based on hundreds of data sets on breast CT volume, a number of studies were performed and reported which have shed light on the basic breast anatomy specific to dosimetry in mammography. It was shown that the average skin thickness of the breast was approximately 1.5 mm, instead of the 4 or 5 mm in the past. In another study, 3-D breast CT data sets were used for validation of the 2-D algorithm developed at the University of Toronto, leading to data suggesting that the overall average breast density is of the order of 16–20%, rather than the previously assumed 50%. Both of these assumptions led to normalized glandular dose (DgN) coefficients which are higher than those of the past. However, a comprehensive study on hundreds of breast CT data sets confirmed the findings of other investigators that there is a more centralized average location of glandular tissue within the breast. Combined with Monte Carlo studies for dosimetry, when accurate models of the distribution of glandular tissue were used, a 30% reduction in the radiation dose (as determined by the DgN coefficient) was found as an average across typical molybdenum and tungsten spectra used clinically. The 30% average reduction was found even when the thinner skin and the lower average breast density were considered. The article reviews three specific anatomic observations made possible based on high-resolution breast CT data by several different research groups. It is noted that, periodically, previous assumptions pertaining to dosimetry can be updated when new information becomes available, so that more accurate dosimetry is achieved. Dogmatic practices typically change slowly, but it is hoped that the medical physics community will continue to evaluate changes in DgN coefficients such that they become more accurate. © 2017, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:129 / 141
页数:12
相关论文
共 50 条
  • [1] Using ERPs to Investigate Two-Dimensional and Three-Dimensional Image Recognition
    Liu, Bao-Yuan
    Liu, Chia-Ju
    [J]. JOURNAL OF RESEARCH IN EDUCATION SCIENCES, 2012, 57 (02): : 1 - 23
  • [2] Determination of three-dimensional displacement using two-dimensional digital image correlation
    Quan, Chenggen
    Tay, Cho Jui
    Sun, Wei
    He, Xiaoyuan
    [J]. APPLIED OPTICS, 2008, 47 (04) : 583 - 593
  • [3] Comparison of two-dimensional verses three-dimensional breast cancer models in drug discovery
    Lovitt, Carrie J.
    Avery, Vicky M.
    [J]. CANCER RESEARCH, 2012, 72
  • [4] Concepts for critical organ dosimetry in three-dimensional image-based breast brachytherapy
    Berger, Daniel
    Kauer-Dorner, Daniela
    Seitz, Wolfgang
    Poetter, Richard
    Kirisits, Christian
    [J]. BRACHYTHERAPY, 2008, 7 (04) : 320 - 326
  • [5] A three-dimensional image processing method based on data layered two-dimensional normalization
    Zhu, Bibo
    Jiang, Hanlei
    Cong, Weihua
    [J]. CONFERENCE PROCEEDINGS OF 2019 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMMUNICATIONS AND COMPUTING (IEEE ICSPCC 2019), 2019,
  • [6] Three-dimensional scene reconstruction from a two-dimensional image
    Parkins, Franz
    Jacobs, Eddie
    [J]. GEOSPATIAL INFORMATICS, FUSION, AND MOTION VIDEO ANALYTICS VII, 2017, 10199
  • [7] Three-dimensional tomosynthesis versus two-dimensional mammography in detection and characterization of different breast lesions
    Abdelattef, Samia Aboelnour Abdeltwab
    Ibrahim, Suzan Farouk
    Abdelhamid, Wafaa Raft
    Mahmoud, Fatten Mohamed
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [8] Three-dimensional tomosynthesis versus two-dimensional mammography in detection and characterization of different breast lesions
    Samia Aboelnour Abdeltwab Abdelattef
    Suzan Farouk Ibrahim
    Wafaa Raft Abdelhamid
    Fatten Mohamed Mahmoud
    [J]. Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [9] Differentiation of cancer cells in two-dimensional and three-dimensional breast cancer models by Raman spectroscopy
    Damayanti, Nur P.
    Fang, Yi
    Parikh, Mukti R.
    Craig, Ana Paula
    Kirshner, Julia
    Irudayaraj, Joseph
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (11)
  • [10] Three-dimensional image processing for breast cancer using multislice CT
    Yamamoto, S
    Hamada, S
    Johkoh, T
    Inoue, T
    Tamaki, Y
    Murai, S
    Tomiyama, N
    Tomoda, K
    Nakamura, H
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1312 - 1312