Concepts for critical organ dosimetry in three-dimensional image-based breast brachytherapy

被引:17
|
作者
Berger, Daniel [1 ]
Kauer-Dorner, Daniela [1 ]
Seitz, Wolfgang [1 ]
Poetter, Richard [1 ]
Kirisits, Christian [1 ]
机构
[1] Med Univ Vienna, Gen Hosp Vienna, Dept Radiotherapy, A-1090 Vienna, Austria
关键词
Brachytherapy; Breast; Organ at risk; Skin; Image-based dosimetry;
D O I
10.1016/j.brachy.2008.08.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To investigate dose-volume histogram (DVH) parameters for organs at risk (OARs) in sectional three-dimensional image-based accelerated partial breast irradiation. METHODS AND MATERIALS: Skin, lung, and ribs were defined as OARs and the heart was discussed. Two different skin-contouring methods were tested on phantom before applying to the patient cohort. First, an inside skin wall contour was delineated with three different wall thicknesses to demonstrate the influence of contouring on DVH parameter. Second a structure was defined, delineated outside of the phantom surface, such that a three-dimensional skin volume was extended like a virtual bolus contour. Point dose values and DVH parameters were reported for 25 patient cases. RESULTS: The DVH parameters D-0.1 (cc) = 65 +/- 21, D-1 cc = 45 +/- 8, D-10 cc = 30 +/- 4 cGy/pulse for the outside skin structure around the breast corresponded to skin surface areas of 1 +/- 1, 6 +/- 3, and 6 +/- 11 cm(2). Lung volume receiving 20 Gy(alpha beta 3) was 8.3 +/- 11 cm(3). D-0.1 cc and D-2 cc in the most exposed rib were 0.7 +/- 0.3 and 0.4 +/- 0.2 Gy/pulse, respectively. CONCLUSION: In accelerated partial breast irradiation treatment planning, dose to OAR can be reported in a more sophisticated way with DVH parameters than using points only. The suggested method of skin delineation using the defined outside structure allows calculating reliable and reproducible DVH parameters. (C) 2008 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:320 / 326
页数:7
相关论文
共 50 条
  • [1] Image-based three-dimensional conformal brachytherapy for medically inoperable endometrial carcinoma
    Gill, Beant S.
    Kim, Hayeon
    Houser, Chris
    Olsen, Adam
    Kelley, Joseph
    Edwards, Robert P.
    Comeici, John
    Sukumvanich, Paniti
    Olawaiye, Alexander B.
    Huang, Marilyn
    Courtney-Brooks, Madeleine
    Beriwal, Sushil
    [J]. BRACHYTHERAPY, 2014, 13 (06) : 542 - 547
  • [2] Three-dimensional dosimetry in brachytherapy: A MAGAT study
    Lin, Min-Hsing
    Huang, Tzung-Chi
    Kao, Ming-Jen
    Wu, Jay
    Chen, Chia-Lin
    Wu, Tung-Hsin
    [J]. APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1432 - 1437
  • [3] Three-dimensional image-based high-dose-rate interstitial brachytherapy for vaginal cancer
    Beriwal, Sushi
    Rwigema, Jean-Claude M.
    Higgins, Emma
    Kim, Hayeon
    Houser, Chris
    Sukumvanich, Paniti
    Olawaiye, Alexander
    Richard, Scott
    Kelley, Joseph L.
    Edwards, Robert P.
    Krivak, Thomas C.
    [J]. BRACHYTHERAPY, 2012, 11 (03) : 176 - 180
  • [4] Three-dimensional image-based high-dose-rate interstitial brachytherapy for mobile tongue cancer
    Yoshida, Ken
    Takenaka, Tadashi
    Akiyama, Hironori
    Yamazaki, Hideya
    Yoshida, Mineo
    Masui, Koji
    Kotsuma, Tadayuki
    Baek, SungJae
    Uesugi, Yasuo
    Shimbo, Taiju
    Yoshikawa, Nobuhiko
    Arika, Takumi
    Koretsune, Yukihiro
    Yoshioka, Yasuo
    Narumi, Yoshifumi
    Tanaka, Eiichi
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) : 154 - 161
  • [5] Two-dimensional breast dosimetry improved using three-dimensional breast image data
    Boone J.M.
    Hernandez A.M.
    Seibert J.A.
    [J]. Radiological Physics and Technology, 2017, 10 (2) : 129 - 141
  • [6] Image-based Simulation of the Three-dimensional Coronary Blood Flow
    Quatember, B.
    Mayr, M.
    Recheis, W.
    [J]. MODSIM 2007: INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION: LAND, WATER AND ENVIRONMENTAL MANAGEMENT: INTEGRATED SYSTEMS FOR SUSTAINABILITY, 2007, : 427 - 433
  • [7] IMAGE-BASED THREE-DIMENSIONAL FREE VIEWPOINT VIDEO SYNTHESIS
    Aliprandi, Davide
    Piccinelli, Emiliano
    [J]. 2009 3DTV-CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO, 2009, : 97 - 100
  • [8] Is the Bladder Foley Point Dose Still An Effective Dose Factor for Three-Dimensional Image-Based Vaginal Brachytherapy?
    Chen, S.
    Longo, J.
    Wahl, A.
    Enke, C.
    Zhou, S.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Improving image-based visual servoing with three-dimensional features
    Cervera, E
    del Pobil, AP
    Berry, F
    Martinet, P
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2003, 22 (10-11): : 821 - 839
  • [10] Three-dimensional image-based mechanical modeling for predicting the response of breast cancer to neoadjuvant therapy
    Weis, Jared A.
    Miga, Michael I.
    Yankeelov, Thomas E.
    [J]. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2017, 314 : 494 - 512