Assessing mechanical catheter dysfunction in automated tidal peritoneal dialysis using cycler software: a case control, proof-of-concept study

被引:0
|
作者
Krystell Oviedo Flores
Lukas Kaltenegger
Fabian Eibensteiner
Markus Unterwurzacher
Klaus Kratochwill
Christoph Aufricht
Franz König
Andreas Vychytil
机构
[1] Medical University of Vienna,Division of Nephrology and Dialysis, Department of Medicine III
[2] Baxter Healthcare GmbH,Division of Pediatric Nephrology and Gastroenterology, Department of Pediatrics and Adolescent Medicine, Comprehensive Center for Pediatrics
[3] Medical University of Vienna,Christian Doppler Laboratory for Molecular Stress Research in Peritoneal Dialysis
[4] Medical University of Vienna,Center for Medical Statistics, Informatics and Intelligent Systems
[5] Medical University of Vienna,undefined
来源
Scientific Reports | / 12卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
New recommendations on evaluation of peritoneal membrane function suggest ruling out catheter dysfunction when evaluating patients with low ultrafiltration capacity. We introduce the use of a combination of parameters obtained from the cycler software PD Link with HomeChoicePro (Baxter International Inc., Illinois, United States) cyclers for predicting catheter dysfunction in automated peritoneal dialysis patients (APD). Out of 117 patients treated at the Medical University of Vienna between 2015 and 2021, we retrospectively identified all patients with verified catheter dysfunction (n = 14) and compared them to controls without clinical evidence of mechanical catheter problems and a recent X-ray confirming PD catheter tip in the rectovesical/rectouterine space (n = 19). All patients had a coiled single-cuff PD catheter, performed tidal PD, and received neutral pH bicarbonate/lactate-buffered PD fluids with low-glucose degradation products on APD. Icodextrin-containing PD fluids were used for daytime dwells. We retrieved cycler data for seven days each and tested parameters' predictive capability of catheter dysfunction. Total number of alarms/week > 7 as single predictive parameter of catheter dislocation identified 85.7% (sensitivity) of patients with dislocated catheter, whereas 31.6% (1-specificity) of control patients were false positive. A combination of parameters (number of alarms/week > 7, total drain time > 22 min, ultrafiltration of last fill < 150 mL) where at least two of three parameters appeared identified the same proportion of patients with catheter dislocation, but was more accurate in identifying controls (21.1% false positive). In contrast to yearly PET measurements, an easily applicable combination of daily cycler readout parameters, also available in new APD systems connected to remote monitoring platforms shows potential for diagnosis of catheter dysfunction during routine follow-up.
引用
收藏
相关论文
共 48 条
  • [41] Detection of histidine-rich protein 2-and/or 3-deleted Plasmodium falciparum using the automated hematology analyzer XN-31: A proof-of-concept study
    Tougan, Takahiro
    Hiyoshi, Fumiya
    Itagaki, Sawako
    Horii, Toshihiro
    PARASITOLOGY INTERNATIONAL, 2022, 91
  • [42] Using Continuous Passive Assessment Technology to Describe Health and Behavior Patterns Preceding and Following a Cancer Diagnosis in Older Adults: Proof-of-Concept Case Series Study
    Wu, Chao-Yi
    Tibbitts, Deanne
    Beattie, Zachary
    Dodge, Hiroko
    Shannon, Jackilen
    Kaye, Jeffrey
    Winters-Stone, Kerri
    JMIR FORMATIVE RESEARCH, 2023, 7
  • [43] Control of the dynamics of a boiling vapour bubble using pressure-modulated high intensity focused ultrasound without the shock scattering effect: A first proof-of-concept study
    Pahk, Ki Joo
    ULTRASONICS SONOCHEMISTRY, 2021, 77 (77)
  • [44] Proof-of-Concept Study of Using Supervised Machine Learning Algorithms to Predict Self-Care and Glycemic Control in Type 1 Diabetes Patients on Insulin Pump Therapy
    Kurdi, Sawsan
    Alamer, Ahmad
    Wali, Haytham
    Badr, Aisha F.
    Pendergrass, Merri L.
    Ahmed, Nehad
    Abraham, Ivo
    Fazel, Maryam T.
    ENDOCRINE PRACTICE, 2023, 29 (06) : 448 - 455
  • [45] Enabling large-scale transit microsimulation for disruption response support using the Nexus platform: Proof-of-concept case study of the Greater Toronto Area transit network
    Srikukenthiran S.
    Shalaby A.
    Public Transport, 2017, 9 (1-2) : 411 - 435
  • [46] Integrating publicly available information to screen potential candidates for chemical prioritization under the Toxic Substances Control Act: A proof of concept case study using genotoxicity and carcinogenicity
    Patlewicz, Grace
    Dean, Jeffry L.
    Gibbons, Catherine F.
    Judson, Richard S.
    Keshava, Nagalakshmi
    Vegosen, Leora
    Martin, Todd M.
    Pradeep, Prachi
    Simha, Anita
    Warren, Sarah H.
    Gwinn, Maureen R.
    Demarini, David M.
    COMPUTATIONAL TOXICOLOGY, 2021, 20
  • [47] A Novel Architecture for Testing and Evaluating Programmable Logic Controller (PLC) Based Control Systems Using Software-in-the-Loop (SIL): A Naval Hull, Mechanical, and Electrical (HM&E) Subsystem Case Study
    Rogers, Jonathan
    Vanaman, Daniel
    Ripple, John
    2024 IEEE AUTOTESTCON, 2024,
  • [48] A novel approach of using brachial plexus blockade as an experimental model for diagnosis of intraoperative nerve dysfunction with somatosensory evoked potentials: a blinded proof-of-concept study; [Une approche innovante utilisant le bloc du plexus brachial comme modèle expérimental pour diagnostiquer une dysfonction nerveuse peropératoire avec des potentiels évoqués somesthésiques : une étude de démonstration de faisabilité en aveugle]
    Chui J.
    Freytag A.
    Glimore G.
    Dhir S.
    Rachinsky M.
    Murkin J.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2021, 68 (7): : 1018 - 1027