The SARS-CoV-2 viral load in COVID-19 patients is lower on face mask filters than on nasopharyngeal swabs

被引:0
|
作者
Agnieszka Smolinska
David S. Jessop
Kirk L. Pappan
Alexandra De Saedeleer
Amerjit Kang
Alexandra L. Martin
Max Allsworth
Charlotte Tyson
Martine P. Bos
Matt Clancy
Mike Morel
Tony Cooke
Tom Dymond
Claire Harris
Jacqui Galloway
Paul Bresser
Nynke Dijkstra
Viresh Jagesar
Paul H. M. Savelkoul
Erik V. H. Beuken
Wesley H. V. Nix
Renaud Louis
Muriel Delvaux
Doriane Calmes
Benoit Ernst
Simona Pollini
Anna Peired
Julien Guiot
Sara Tomassetti
Andries E. Budding
Frank McCaughan
Stefan J. Marciniak
Marc P. van der Schee
机构
[1] Owlstone Medical Ltd.,Department of Pharmacology and Toxicology
[2] Maastricht University,Department of Medicine
[3] inBiome B.V.,Pulmonology
[4] Cambridge Clinical Laboratories Ltd.,Department of Medical Microbiology
[5] Cambridge University Hospitals NHS Foundation Trust,Repiratory Department
[6] Addenbrooke’s Hospital,Department of Experimental and Clinical Medicine
[7] Addenbrooke’s Hospital,Microbiology and Virology Unit
[8] University of Cambridge,Department of Experimental and Clinical Biomedical Sciences “Mario Serio”
[9] OLVG,Interventional Pulmonology Unit
[10] Maastricht University Medical Center,undefined
[11] Care and Public Health Research Institute (Caphri),undefined
[12] CHU Liège,undefined
[13] University of Florence,undefined
[14] Careggi University Hospital,undefined
[15] University of Florence,undefined
[16] Careggi University Hospital,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Face masks and personal respirators are used to curb the transmission of SARS-CoV-2 in respiratory droplets; filters embedded in some personal protective equipment could be used as a non-invasive sample source for applications, including at-home testing, but information is needed about whether filters are suited to capture viral particles for SARS-CoV-2 detection. In this study, we generated inactivated virus-laden aerosols of 0.3–2 microns in diameter (0.9 µm mean diameter by mass) and dispersed the aerosolized viral particles onto electrostatic face mask filters. The limit of detection for inactivated coronaviruses SARS-CoV-2 and HCoV-NL63 extracted from filters was between 10 to 100 copies/filter for both viruses. Testing for SARS-CoV-2, using face mask filters and nasopharyngeal swabs collected from hospitalized COVID-19-patients, showed that filter samples offered reduced sensitivity (8.5% compared to nasopharyngeal swabs). The low concordance of SARS-CoV-2 detection between filters and nasopharyngeal swabs indicated that number of viral particles collected on the face mask filter was below the limit of detection for all patients but those with the highest viral loads. This indicated face masks are unsuitable to replace diagnostic nasopharyngeal swabs in COVID-19 diagnosis. The ability to detect nucleic acids on face mask filters may, however, find other uses worth future investigation.
引用
收藏
相关论文
共 50 条
  • [21] Transpulmonary electrotherapy for reduction of lung viral load of SARS-CoV-2 in patients with COVID-19
    Kipshidze, Nicholas
    Chekanov, Valeri S.
    Kipshidze, Nodar
    Reddy, Vivek Y.
    Dangas, George
    MEDICAL HYPOTHESES, 2020, 143
  • [22] Exhaled SARS-CoV-2 quantified by face-mask sampling in hospitalised patients with COVID-19
    Williams, Caroline M.
    Pan, Daniel
    Decker, Jonathan
    Wisniewska, Anika
    Fletcher, Eve
    Sze, Shirley
    Assadi, Sara
    Haigh, Richard
    Abdulwhhab, Mohamad
    Bird, Paul
    Holmes, Christopher W.
    Al-Taie, Alaa
    Saleem, Baber
    Pan, Jingzhe
    Garton, Natalie J.
    Pareek, Manish
    Barer, Michael R.
    JOURNAL OF INFECTION, 2021, 82 (06) : 253 - 259
  • [23] SARS-CoV-2 viral load in heat and humidity exchange filters during invasive mechanical ventilation of patients with COVID-19
    Fulceri, Giorgio Enzo
    Morecchiato, Fabio
    Antonelli, Alberto
    Bonizzoli, Manuela
    Cecchi, Michele
    Rossolini, Gian Maria
    Peris, Adriano
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (06) : E163 - E164
  • [24] Prevalence of SARS-CoV-2 RNA in conjunctival swabs of symptomatic COVID-19 patients
    Veugen, J. M. J.
    Gijs, M.
    Wolffs, P. F. G.
    Savelkoul, P. H. M.
    Tas, J.
    van Bussel, B. C. T.
    de Kruijf, M. D.
    Henry, R. M. A.
    Webers, C. A. B.
    Dickman, M. M.
    Nuijts, R. M. M. A.
    ACTA OPHTHALMOLOGICA, 2021, 99 : 3 - 4
  • [25] Serial Screening for SARS-CoV-2 in Rectal Swabs of Symptomatic COVID-19 Patients
    Jung, Sung Hoon
    Kim, Sei Won
    Lee, Heayon
    Oh, Jung Hwan
    Lim, Jihyang
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2021, 36 (44)
  • [26] Relationship between the Viral Load in Patients with Different COVID-19 Severities and SARS-CoV-2 Variants
    Coy-Arechavaleta, Andrea Santos
    Alvarado-Yaah, Julio Elias
    Uribe-Noguez, Luis Antonio
    Guerra-Castillo, Francisco Xavier
    Santacruz-Tinoco, Clara Esperanza
    Ramon-Gallegos, Eva
    Munoz-Medina, Jose Esteban
    Fernandes-Matano, Larissa
    MICROORGANISMS, 2024, 12 (03)
  • [27] SARS-CoV-2 viral load in sputum correlates with risk of COVID-19 progression
    Yu, Xia
    Sun, Shanshan
    Shi, Yu
    Wang, Hao
    Zhao, Ruihong
    Sheng, Jifang
    CRITICAL CARE, 2020, 24 (01):
  • [28] SARS-CoV-2 viral load in the upper respiratory tract and disease severity in COVID-19 patients
    Wattana Leowattana
    Tawithep Leowattana
    Pathomthep Leowattana
    World Journal of Meta-Analysis, 2022, (04) : 195 - 205
  • [29] Eigenvalue analysis of SARS-CoV-2 viral load data: illustration for eight COVID-19 patients
    Till D. Frank
    International Journal of Data Science and Analytics, 2023, 15 : 281 - 290
  • [30] SARS-CoV-2 viral load in sputum correlates with risk of COVID-19 progression
    Xia Yu
    Shanshan Sun
    Yu Shi
    Hao Wang
    Ruihong Zhao
    Jifang Sheng
    Critical Care, 24