Standardization of 90Y solution by mean of a Cherenkov counting in comparison with a liquid scintillation counting technique

被引:0
|
作者
Tomasz Ziemek
Edyta Lech
Zbigniew Tymiński
机构
[1] National Centre of Nuclear Research,Radioisotope Centre POLATOM
关键词
Standardization of ; Y solution; Cherenkov method; TDCR detector; Liquid scintillation counting method;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the standardization of 90Y solution using the Cherenkov method measuring in the TDCR counters. The counting efficiencies for the production of Cherenkov light were applying the Frank and Tamm theory. The detection efficiency for the TDCR counter was calculated in a home-made code. The calculation took into account the PMT’s asymmetry in the detector and the anisotropy of Cherenkov light propagation. The solution was measured in two different TDCR detectors using the Cherenkov and Liquid Scintillation Counting methods. The agreement of the two methods results was below 0.1%.
引用
收藏
页码:3327 / 3333
页数:6
相关论文
共 50 条
  • [21] STANDARDIZATION OF TC-99 BY LIQUID-SCINTILLATION COUNTING
    COURSEY, BM
    GIBSON, JAB
    HEITZMANN, MW
    LEAK, JC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (12): : 1103 - 1112
  • [22] AUTOMATIC QUENCH DETERMINATION IN LIQUID SCINTILLATION COUNTING BY EXTERNAL STANDARDIZATION
    SCHRODT, AG
    CAVANAUGH, R
    GIBBS, J
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1964, 7 (02): : 339 - &
  • [23] Standardization of pure beta emitters by liquid-scintillation counting
    Pochwalski, K.
    Broda, R.
    Radoszewski, T.
    Applied Radiation and Isotopes, 1988, 39 (02): : 165 - 172
  • [24] Activity standardization of 123I by liquid scintillation counting
    Takacs, Marcell P.
    Kossert, Karsten
    Naehle, Ole
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025,
  • [25] Standardization of electron-capture radionuclides by liquid scintillation counting
    Malonda, AG
    Carles, AG
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 657 - 662
  • [26] Modified 2-window approach for rapid determination of 90Sr and 90Y at low quench level using liquid scintillation counting
    Xiao-gui Feng
    Qian-ge He
    Jian-chen Wang
    Jing Chen
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 299 : 509 - 516
  • [27] Quantitative Comparison of Liquid Scintillation Counting Spectra
    Gerganov, G.
    Mitev, K.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [28] A quick liquid scintillation counting technique for analysis of 90Sr in environmental samples
    Wang, Jeng-Jong
    APPLIED RADIATION AND ISOTOPES, 2013, 81 : 169 - 174
  • [29] Standardization of rapid screening technique based on liquid scintillation counting for estimation of gross α/β activities in urine
    Prabhu, S. P.
    Bhade, S. P. D.
    Sawant, P. D.
    Kulkarni, M. S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (01) : 179 - 192
  • [30] Standardization of rapid screening technique based on liquid scintillation counting for estimation of gross α/β activities in urine
    S. P. Prabhu
    S. P. D. Bhade
    P. D. Sawant
    M. S. Kulkarni
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 179 - 192