Viscosity measurements of hydrous rhyolitic melts using the fiber elongation method

被引:0
|
作者
Akio Goto
Hiromitsu Taniguchi
Arashi Kitakaze
机构
[1] Tohoku University,The Center for Northeast Asian Studies
来源
Bulletin of Volcanology | 2005年 / 67卷
关键词
Viscosity; Silicate melts; Hydrous; Fiber elongation method; Autoclave; Calcalkaline; Rhyolite;
D O I
暂无
中图分类号
学科分类号
摘要
We have devised a new, simple and easy technique to measure the viscosity of hydrous silicate melts by combining an autoclave for melt hydration and the fiber elongation method for viscosity measurement. Using this, we measured the viscosity of hydrous rhyolitic melts whose water content ranges from 0.02 to 0.58 wt%. We observed a drastic decrease in viscosity against water content: 0.1 wt% water decreases the viscosity about an order of magnitude. Even when the water content is only 0.02 wt%, the viscosity decreased about half an order of magnitude. These results clearly demonstrate that the effect of water on viscosity should not be ignored even when it occurs as a trace constituent. We compared our experimental data with those derived from a non-Arrhenian viscosity model, which is considered to be applicable to calc-alkaline samples. This model succeeded in expressing the viscosity variation against water content but was unable to accurately predict the measured viscosity of liquids.
引用
收藏
页码:590 / 596
页数:6
相关论文
共 50 条
  • [41] Stress and birefringence measurements during the uniaxial elongation of polystyrene melts
    Venerus, DC
    Zhu, SH
    Öttinger, HC
    JOURNAL OF RHEOLOGY, 1999, 43 (03) : 795 - 813
  • [42] Viscosity measurements of glass melts -: Certification of reference material
    Böse, N
    Klingenberg, G
    Meerlender, G
    GLASS SCIENCE AND TECHNOLOGY-GLASTECHNISCHE BERICHTE, 2001, 74 (05): : 115 - 126
  • [43] SIMULTANEOUS MEASUREMENTS OF DENSITY, VISCOSITY, AND ELECTRIC CONDUCTIVITY OF MELTS
    MACKENZIE, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (05): : 297 - 299
  • [44] Equibiaxial Elongational Viscosity Measurements of Commercial Polymer Melts
    Mick, Rebecca M.
    Shiu, Tai-Yi
    Venerus, David C.
    POLYMER ENGINEERING AND SCIENCE, 2015, 55 (05): : 1012 - 1017
  • [45] MEASUREMENTS OF HUMAN AND ARTIFICIAL BLOOD-VISCOSITY USING A SIMPLE METHOD WITH A POLYPROPYLENE HOLLOW FIBER OXYGENATOR
    TSUJI, T
    TOGAWA, T
    OKADA, M
    MUNEOKA, K
    OKAMOTO, M
    BIORHEOLOGY, 1987, 24 (05) : 527 - 527
  • [46] Influence of side-chain structures on the viscoelasticity and elongation viscosity of polyethylene melts
    Lin, GG
    Shih, HH
    Chai, PC
    Hsu, SJ
    POLYMER ENGINEERING AND SCIENCE, 2002, 42 (11): : 2213 - 2221
  • [47] Is Faxen's correction function applicable to viscosity measurements of silicate melts with the falling sphere method?
    Kahle, A
    Winkler, B
    Hennion, B
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2003, 112 (2-3) : 203 - 215
  • [48] Torsion pendulum method in viscosity measurement of melts
    Hong, XG
    Lu, KQ
    CHINESE PHYSICS LETTERS, 1995, 12 (11): : 641 - 644
  • [49] Simple method for theoretical estimation of viscosity of oxide melts using optical basicity
    Ray, HS
    Pal, S
    IRONMAKING & STEELMAKING, 2004, 31 (02) : 125 - 130
  • [50] Laboratory measurements of electrical conductivity of hydrous and dry silicic melts under pressure
    Gaillard, F
    EARTH AND PLANETARY SCIENCE LETTERS, 2004, 218 (1-2) : 215 - 228