Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system

被引:0
|
作者
Andreas Steven Kunz
Theresa Sophie Patzer
Jan-Peter Grunz
Karsten Sebastian Luetkens
Viktor Hartung
Robin Hendel
Tabea Fieber
Franca Genest
Süleyman Ergün
Thorsten Alexander Bley
Henner Huflage
机构
[1] University Hospital Würzburg,Department of Diagnostic and Interventional Radiology
[2] University Hospital Würzburg,Department of Trauma, Hand, Plastic and Reconstructive Surgery
[3] Julius-Maximilians-Universität Würzburg,Orthopedic Clinic König
[4] University of Würzburg,Ludwig
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Cone-beam computed tomography (CBCT) has been shown to be a powerful tool for 3D imaging of the appendicular skeleton, allowing for detailed visualization of bone microarchitecture. This study was designed to compare artifacts in the presence of osteosynthetic implants between CBCT and multidetector computed tomography (MDCT) in cadaveric wrist scans. A total of 32 scan protocols with varying tube potential and current were employed: both conventional CBCT and MDCT studies were included with tube voltage ranging from 60 to 140 kVp as well as additional MDCT protocols with dedicated spectral shaping via tin prefiltration. Irrespective of scanner type, all examinations were conducted in ultra-high-resolution (UHR) scan mode. For reconstruction of UHR-CBCT scans an additional iterative metal artifact reduction algorithm was employed, an image correction tool which cannot be used in combination with UHR-MDCT. To compare applied radiation doses between both scanners, the volume computed tomography dose index for a 16 cm phantom (CTDIvol) was evaluated. Images were assessed regarding subjective and objective image quality. Without automatic tube current modulation or tube potential control, radiation doses ranged between 1.3 mGy (with 70 kVp and 50.0 effective mAs) and 75.2 mGy (with 140 kVp and 383.0 effective mAs) in UHR-MDCT. Using the pulsed image acquisition method of the CBCT scanner, CTDIvol ranged between 2.3 mGy (with 60 kVp and 0.6 mean mAs per pulse) and 61.0 mGy (with 133 kVp and 2.5 mean mAs per pulse). In essence, all UHR-CBCT protocols employing a tube potential of 80 kVp or more were found to provide superior overall image quality and artifact reduction compared to UHR-MDCT (all p < .050). Interrater reliability of seven radiologists regarding image quality was substantial for tissue assessment and moderate for artifact assessment with Fleiss kappa of 0.652 (95% confidence interval 0.618–0.686; p < 0.001) and 0.570 (95% confidence interval 0.535–0.606; p < 0.001), respectively. Our results demonstrate that the UHR-CBCT scan mode of a twin robotic X-ray system facilitates excellent visualization of the appendicular skeleton in the presence of metal implants. Achievable image quality and artifact reduction are superior to dose-comparable UHR-MDCT and even MDCT protocols employing spectral shaping with tin prefiltration do not achieve the same level of artifact reduction in adjacent soft tissue.
引用
收藏
相关论文
共 50 条
  • [41] X-ray scatter correction algorithm for 450 KeV cone-beam CT system
    Dept. of Engineering Physics, Tsinghua University, Beijing 100084, China
    Hedianzixue Yu Tance Jishue, 2006, 6 (908-911):
  • [42] Metal Artifact Reduction in X-ray CT Imaging based on Iterative Reconstruction Approach
    Nawaz, Shoukat
    Jian, Fu
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2420 - 2425
  • [43] Comparative Methods for Metal Artifact Reduction in x-ray CT
    Abdoli, Mehrsima
    Mehranian, Abolfazl
    Ailianou, Angeliki
    Becker, Minerva
    Zaidi, Habib
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [44] A hybrid metal artifact reduction algorithm for x-ray CT
    Zhang, Yanbo
    Yan, Hao
    Jia, Xun
    Yang, Jian
    Jiang, Steve B.
    Mou, Xuanqin
    MEDICAL PHYSICS, 2013, 40 (04)
  • [45] Evaluation of scatter mitigation strategies for X-ray cone-beam CT
    Lasio, G.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2288 - 2289
  • [46] Filtered back projection method for cone-beam X-ray CT
    Matsuo, Hiroshi, 1600, (20):
  • [47] FPGA-acceleration of cone-beam reconstruction for the X-ray CT
    Stsepankou, D
    Kornmesser, K
    Hesser, J
    Männer, R
    2004 IEEE INTERNATIONAL CONFERENCE ON FIELD-PROGRAMMABLE TECHNOLOGY, PROCEEDINGS, 2004, : 327 - 330
  • [48] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [49] Scatter considerations in ultra-high-resolution high-energy X-ray transmission imaging systems
    Wang, LB
    Liu, YO
    Kang, KJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 538 (1-3): : 747 - 755
  • [50] Single-Energy Metal Artifact Reduction (SEMAR) in Ultra-High-Resolution CT Angiography of Patients with Intracranial Implants
    Jabas, Abdullah
    Mercado, Mario Alberto Abello
    Altmann, Sebastian
    Ringel, Florian
    Booz, Christian
    Kronfeld, Andrea
    Sanner, Antoine P.
    Brockmann, Marc A.
    Othman, Ahmed E.
    DIAGNOSTICS, 2023, 13 (04)