Production of medical radioisotopes with high specific activity in photonuclear reactions with γ-beams of high intensity and large brilliance

被引:0
|
作者
D. Habs
U. Köster
机构
[1] Ludwig Maximilians Universität München,Fakultät für Physik
[2] Institut Laue Langevin,undefined
来源
Applied Physics B | 2011年 / 103卷
关键词
Neutron Capture; Electron Bunch; Photonuclear Reaction; Neutron Binding Energy; Beam Facility;
D O I
暂无
中图分类号
学科分类号
摘要
We study the production of radioisotopes for nuclear medicine in (γ,xn+yp) photonuclear reactions or (γ,γ′) photoexcitation reactions with high-flux [(1013–1015)γ/s], small diameter ∼(100 μm)2 and small bandwidth (ΔE/E≈10−3–10−4) γ beams produced by Compton back-scattering of laser light from relativistic brilliant electron beams. We compare them to (ion,xn+yp) reactions with (ion = p,d,α) from particle accelerators like cyclotrons and (n,γ) or (n,f) reactions from nuclear reactors. For photonuclear reactions with a narrow γ-beam the energy deposition in the target can be managed by using a stack of thin target foils or wires, hence avoiding direct stopping of the Compton and pair electrons (positrons). However, for ions with a strong atomic stopping only a fraction of less than 10−2 leads to nuclear reactions resulting in a target heating, which is at least 105 times larger per produced radioactive ion and often limits the achievable activity. In photonuclear reactions the well defined initial excitation energy of the compound nucleus leads to a small number of reaction channels and enables new combinations of target isotope and final radioisotope. The narrow bandwidth γ excitation may make use of the fine structure of the Pygmy Dipole Resonance (PDR) or fluctuations in γ-width leading to increased cross sections. Within a rather short period compared to the isotopic half-life, a target area of the order of (100 μm)2 can be highly transmuted, resulting in a very high specific activity. (γ,γ′) isomer production via specially selected γ cascades allows to produce high specific activity in multiple excitations, where no back-pumping of the isomer to the ground state occurs. We discuss in detail many specific radioisotopes for diagnostics and therapy applications. Photonuclear reactions with γ-beams allow to produce certain radioisotopes, e.g. 47Sc, 44Ti, 67Cu, 103Pd, 117mSn, 169Er, 195mPt or 225Ac, with higher specific activity and/or more economically than with classical methods. This will open the door for completely new clinical applications of radioisotopes. For example 195mPt could be used to verify the patient’s response to chemotherapy with platinum compounds before a complete treatment is performed. Also innovative isotopes like 47Sc, 67Cu and 225Ac could be produced for the first time in sufficient quantities for large-scale application in targeted radionuclide therapy.
引用
收藏
页码:501 / 519
页数:18
相关论文
共 50 条
  • [21] Targets for the production of high intensity radioactive ion beams
    Bennett, JRJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4): : 105 - 112
  • [22] Production of high intensity Beta beams at the ISOLDE facility
    Hodak, Rastislav
    Stora, Thierry
    Mendonca, Tania M.
    WORKSHOP ON CALCULATION OF DOUBLE-BETA-DECAY MATRIX ELEMENTS (MEDEX '11), 2011, 1417
  • [23] PRODUCTION OF HIGH SPECIFIC ACTIVITY CHROMIUM-51 FOR MEDICAL USES
    IQBAL, M
    EJAZ, M
    RADIOCHIMICA ACTA, 1975, 22 (1-2) : 49 - 50
  • [24] PRODUCTION AND DYNAMICS OF HIGH-INTENSITY ELECTRON-BEAMS
    BOSCOLO, I
    LEO, M
    LUCHES, A
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (02): : 194 - 194
  • [25] PRODUCTION OF HIGH-INTENSITY HYDROGEN-ION BEAMS
    DIMOV, GI
    KONONENK.YG
    SAVCHENK.OY
    SHAMOVSK.VG
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1968, 13 (06): : 754 - &
  • [26] PRODUCTION OF LOW DIVERGENCE POSITIVE ION BEAMS OF HIGH INTENSITY
    BROOKS, NB
    ROSE, PH
    BASTIDE, RP
    WITTKOWER, AB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 894 - &
  • [27] PRODUCTION AND DYNAMICS OF HIGH-INTENSITY ELECTRON-BEAMS
    BRAUTTI, G
    BOSCOJO, I
    COISSON, R
    LEO, M
    LUCHES, A
    TEPORE, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (03) : 286 - 288
  • [28] Production of high intensity highly charged cocktail beams at LEAF
    Zhai, Y. H.
    Yang, Y.
    Sun, L. T.
    Jing, L.
    Gao, Z.
    Guo, Y. H.
    Zhang, P.
    Zhang, B.
    Tang, Y.
    Chang, J. J.
    Zhao, H. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [29] MEASUREMENTS IN HIGH-INTENSITY BEAMS FROM MEDICAL LINEAR ACCELERATORS
    OBRIEN, PF
    BARNETT, RB
    MICHAELS, HB
    SIWEK, RA
    MEDICAL PHYSICS, 1987, 14 (06) : 1067 - 1070
  • [30] Operational radiation protection issues specific to high-intensity beams
    Nakashima, Hiroshi
    RADIATION PROTECTION DOSIMETRY, 2009, 137 (1-2) : 35 - 50