Triple point data are important in the refrigerating industry, defining the lowest temperature limit at which a refrigerant may circulate in a fluid state. For several refrigerants, triple point data present in the literature are extremely scarce or inaccurate. A recently developed Solid–Liquid Equilibria (SLE) apparatus was used to measure the triple point temperature of 16 of the most widely applied alternative refrigerants, namely three methane derivatives (fluoromethane, R41; difluoromethane, R32; trifluoromethane, R23), four ethane derivatives (pentafluoroethane, R125; 1,1,1,2-tetrafluoroethane, R134a; 1,1,1-trifluoroethane, R143a; 1,1-difluoroethane, R152a), five propane derivatives [1,1,1,2,3,3,3-heptafluoropropane, R227ea; 1,1,2,3,3,3-hexafluoropropane, R236ea; 1,1,1,3,3-Pentafluoropropane, R245fa; 1,1,2,2,3-pentafluoropropane, R245ca; 1,1,1,3,3,3-hexafluoropropane, R236fa), and four hydrofluoro-olefines (2,3,3,3-tetrafluoroprop-1-ene, R1234yf; trans-1,3,3,3 tetrafluoropropene, R1234ze(E); 3,3,3-trifluoropropene, R1243zf; 1,2,3,3,3-pentafluoropropene, 1225ye(Z)]. The experimental setup, that was recently adopted for the SLE estimation of binary systems containing carbon dioxide (J Therm Anal Calorim 105:489–493, 2011), comprises a measuring cell and a system for drawing the liquid nitrogen directly from its insulated tank with the aid of compressed air: the carrier fluid circulating in the circuit is thus the refrigerant itself. The measurements were performed both in the heating and in the cooling mode. In order to confirm the functional efficiency and fine adjustment of the apparatus, the already available triple point literature data for carbon dioxide, dimethyl ether, and nitrous oxide were also compared with the ones measured by the present setup, confirming the validity of the setup. The measured triple point data for the refrigerants revealed generally good agreement with the literature, excepting a few fluids that revealed some discrepancies.
引用
收藏
页码:627 / 631
页数:4
相关论文
共 50 条
  • [41] An Alternative Method for Manufacturing Water Triple-Point Cells
    Quelhas, K. N.
    Teixeira, R. N.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (6-7) : 1097 - 1108
  • [42] An Alternative Method for Manufacturing Water Triple-Point Cells
    K. N. Quelhas
    R. N. Teixeira
    International Journal of Thermophysics, 2014, 35 : 1097 - 1108
  • [43] Description of alternative refrigerants with BACKONE equations
    Depto. Quim. Fundamental e Indust., Facultad de Ciencias, Universidad Coruña, E-15071 A Coruña, Spain
    不详
    Fluid Phase Equilib., 1 (1-22):
  • [44] Screening of pure fluids as alternative refrigerants
    Saleh, B
    Wendland, M
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (02): : 260 - 269
  • [45] AMMONIA AND DIMETHYLETHER BLENDS AS ALTERNATIVE REFRIGERANTS
    Popescu, Traian
    Feidt, Michel
    Apostol, Valentin
    Gheorghe, Popescu
    Pop, Horatiu
    Alionte, Cristian Gabriel
    ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1627 - 1628
  • [46] Dielectric properties of alternative refrigerants - a review
    Mardolcar, UV
    Santos, FJV
    de Castro, CAN
    ICDL: 2005 IEEE INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS, 2005, : 433 - 436
  • [47] Description of alternative refrigerants with BACKONE equations
    Calero, S
    Wendland, M
    Fischer, J
    FLUID PHASE EQUILIBRIA, 1998, 152 (01) : 1 - 22
  • [48] A comparison of the operating performance of alternative refrigerants
    Halimic, E
    Ross, D
    Agnew, B
    Anderson, A
    Potts, I
    APPLIED THERMAL ENGINEERING, 2003, 23 (12) : 1441 - 1451
  • [49] An NTU-ε model for alternative refrigerants
    Bansal, PK
    Purkayastha, B
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (05): : 381 - 397
  • [50] RETROFITTING EXISTING CHILLERS WITH ALTERNATIVE REFRIGERANTS
    CLARK, EM
    ANDERSON, GG
    WELLS, WD
    BATES, RL
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1991, 33 (04): : 38 - 41