Triple point measurements for alternative refrigerants

被引:0
|
作者
Giovanni Di Nicola
Caterina Brandoni
Cristiano Di Nicola
Giuliano Giuliani
机构
[1] Università Politecnica delle Marche,DIISM
[2] Università degli Studi e-Campus,undefined
关键词
Experimental; Refrigerants; Temperature; Triple point;
D O I
暂无
中图分类号
学科分类号
摘要
Triple point data are important in the refrigerating industry, defining the lowest temperature limit at which a refrigerant may circulate in a fluid state. For several refrigerants, triple point data present in the literature are extremely scarce or inaccurate. A recently developed Solid–Liquid Equilibria (SLE) apparatus was used to measure the triple point temperature of 16 of the most widely applied alternative refrigerants, namely three methane derivatives (fluoromethane, R41; difluoromethane, R32; trifluoromethane, R23), four ethane derivatives (pentafluoroethane, R125; 1,1,1,2-tetrafluoroethane, R134a; 1,1,1-trifluoroethane, R143a; 1,1-difluoroethane, R152a), five propane derivatives [1,1,1,2,3,3,3-heptafluoropropane, R227ea; 1,1,2,3,3,3-hexafluoropropane, R236ea; 1,1,1,3,3-Pentafluoropropane, R245fa; 1,1,2,2,3-pentafluoropropane, R245ca; 1,1,1,3,3,3-hexafluoropropane, R236fa), and four hydrofluoro-olefines (2,3,3,3-tetrafluoroprop-1-ene, R1234yf; trans-1,3,3,3 tetrafluoropropene, R1234ze(E); 3,3,3-trifluoropropene, R1243zf; 1,2,3,3,3-pentafluoropropene, 1225ye(Z)]. The experimental setup, that was recently adopted for the SLE estimation of binary systems containing carbon dioxide (J Therm Anal Calorim 105:489–493, 2011), comprises a measuring cell and a system for drawing the liquid nitrogen directly from its insulated tank with the aid of compressed air: the carrier fluid circulating in the circuit is thus the refrigerant itself. The measurements were performed both in the heating and in the cooling mode. In order to confirm the functional efficiency and fine adjustment of the apparatus, the already available triple point literature data for carbon dioxide, dimethyl ether, and nitrous oxide were also compared with the ones measured by the present setup, confirming the validity of the setup. The measured triple point data for the refrigerants revealed generally good agreement with the literature, excepting a few fluids that revealed some discrepancies.
引用
收藏
页码:627 / 631
页数:4
相关论文
共 50 条
  • [1] Triple point measurements for alternative refrigerants
    Di Nicola, Giovanni
    Brandoni, Caterina
    Di Nicola, Cristiano
    Giuliani, Giuliano
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 108 (02) : 627 - 631
  • [2] Measurements of the refractive index of alternative refrigerants
    Yata, J
    Hori, M
    Kawakatsu, H
    Minamiyama, T
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1996, 17 (01) : 65 - 74
  • [3] Solid-liquid equilibria for nitrous oxide plus fluoromethane and triple point measurements for refrigerants
    Di Nicola, Cristiano
    Moglie, Matteo
    Santori, Giulio
    Stryjek, Roman
    Di Nicola, Giovanni
    HIGH TEMPERATURES-HIGH PRESSURES, 2012, 41 (02) : 145 - 158
  • [4] TRIPLE POINT TEMPERATURE FOR FIVE FLUORINATED PROPANE DERIVATIVES REFRIGERANTS
    Di Nicola, G.
    Di Nicola, C.
    Giuliani, G.
    Stryjek, R.
    Polonara, F.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1923 - +
  • [5] Bubble Point Measurements of Mixtures of HFO and HFC Refrigerants
    Outcalt, Stephanie L.
    Rowane, Aaron J.
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2021, 66 (12): : 4670 - 4683
  • [6] ALTERNATIVE REFRIGERANTS
    WARD, RB
    NATURE, 1976, 261 (5561) : 540 - 540
  • [7] ALTERNATIVE REFRIGERANTS
    COTTON, FA
    NATURE, 1976, 260 (5549) : 280 - 280
  • [8] ALTERNATIVE REFRIGERANTS
    MEGAW, WJ
    NATURE, 1976, 261 (5555) : 10 - 10
  • [9] ALTERNATIVE REFRIGERANTS
    JACOB, A
    CHEMICAL ENGINEER-LONDON, 1991, (491): : 14 - 14
  • [10] ALTERNATIVE REFRIGERANTS
    BIRKS, JW
    LECK, TJ
    NATURE, 1976, 260 (5546) : 8 - 8