Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit

被引:0
|
作者
Mauricio Villarroel
Sitthichok Chaichulee
João Jorge
Sara Davis
Gabrielle Green
Carlos Arteta
Andrew Zisserman
Kenny McCormick
Peter Watkinson
Lionel Tarassenko
机构
[1] University of Oxford,Institute of Biomedical Engineering, Department of Engineering Science
[2] Oxford University Hospitals Trust,Neonatal Unit, John Radcliffe Hospital
[3] University of Oxford,Visual Geometry Group, Department of Engineering Science
[4] University of Oxford,Nuffield Department of Clinical Neurosciences
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The implementation of video-based non-contact technologies to monitor the vital signs of preterm infants in the hospital presents several challenges, such as the detection of the presence or the absence of a patient in the video frame, robustness to changes in lighting conditions, automated identification of suitable time periods and regions of interest from which vital signs can be estimated. We carried out a clinical study to evaluate the accuracy and the proportion of time that heart rate and respiratory rate can be estimated from preterm infants using only a video camera in a clinical environment, without interfering with regular patient care. A total of 426.6 h of video and reference vital signs were recorded for 90 sessions from 30 preterm infants in the Neonatal Intensive Care Unit (NICU) of the John Radcliffe Hospital in Oxford. Each preterm infant was recorded under regular ambient light during daytime for up to four consecutive days. We developed multi-task deep learning algorithms to automatically segment skin areas and to estimate vital signs only when the infant was present in the field of view of the video camera and no clinical interventions were undertaken. We propose signal quality assessment algorithms for both heart rate and respiratory rate to discriminate between clinically acceptable and noisy signals. The mean absolute error between the reference and camera-derived heart rates was 2.3 beats/min for over 76% of the time for which the reference and camera data were valid. The mean absolute error between the reference and camera-derived respiratory rate was 3.5 breaths/min for over 82% of the time. Accurate estimates of heart rate and respiratory rate could be derived for at least 90% of the time, if gaps of up to 30 seconds with no estimates were allowed.
引用
收藏
相关论文
共 50 条
  • [1] Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit
    Villarroel, Mauricio
    Chaichulee, Sitthichok
    Jorge, Joao
    Davis, Sara
    Green, Gabrielle
    Arteta, Carlos
    Zisserman, Andrew
    McCormick, Kenny
    Watkinson, Peter
    Tarassenko, Lionel
    [J]. NPJ DIGITAL MEDICINE, 2019, 2 (1)
  • [2] Non-contact monitoring of respiration in the neonatal intensive care unit
    Jorge, Joao
    Villarroel, Mauricio
    Chaichulee, Sitthichok
    Guazzi, Alessandro
    Davis, Sara
    Green, Gabrielle
    McCormick, Kenny
    Tarassenko, Lionel
    [J]. 2017 12TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION (FG 2017), 2017, : 286 - 293
  • [3] Continuous non-contact vital sign monitoring in neonatal intensive care unit
    Villarroel, Mauricio
    Guazzi, Alessandro
    Jorge, Joao
    Davis, Sara
    Watkinson, Peter
    Green, Gabrielle
    Shenvi, Asha
    McCormick, Kenny
    Tarassenko, Lionel
    [J]. HEALTHCARE TECHNOLOGY LETTERS, 2014, 1 (03): : 87 - 91
  • [4] Non-Contact Automatic Vital Signs Monitoring of Infants in a Neonatal Intensive Care Unit Based on Neural Networks
    Khanam, Fatema-Tuz-Zohra
    Perera, Asanka G.
    Al-Naji, Ali
    Gibson, Kim
    Chahl, Javaan
    [J]. JOURNAL OF IMAGING, 2021, 7 (08)
  • [5] Non-contact physiological monitoring of post-operative patients in the intensive care unit
    Jorge, Joao
    Villarroel, Mauricio
    Tomlinson, Hamish
    Gibson, Oliver
    Darbyshire, Julie L.
    Ede, Jody
    Harford, Mirae
    Young, John Duncan
    Tarassenko, Lionel
    Watkinson, Peter
    [J]. NPJ DIGITAL MEDICINE, 2022, 5 (01)
  • [6] Non-contact physiological monitoring of post-operative patients in the intensive care unit
    João Jorge
    Mauricio Villarroel
    Hamish Tomlinson
    Oliver Gibson
    Julie L. Darbyshire
    Jody Ede
    Mirae Harford
    John Duncan Young
    Lionel Tarassenko
    Peter Watkinson
    [J]. npj Digital Medicine, 5
  • [7] Care of Preterm Infants in the Neonatal Intensive Care Unit
    Hack, Maureen
    [J]. PEDIATRICS, 2009, 123 (04) : 1246 - 1247
  • [8] Non-Contact Heart Rate Monitoring in Neonatal Intensive Care Unit using RGB Camera
    Chen, Qiong
    Jiang, Xinyu
    Liu, Xiangyu
    Lu, Chunmei
    Wang, Laishuan
    Chen, Wei
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5822 - 5825
  • [9] Non-Contact Vital-Sign Monitoring System for Premature Infants in Neonatal Intensive Care Units
    Foldesy, Peter
    Janoki, Imre
    Zarandy, Akos
    Pazmany, Peter
    [J]. ERCIM NEWS, 2020, (122): : 50 - 51
  • [10] HANDLING OF PRETERM INFANTS IN A NEONATAL INTENSIVE CARE UNIT
    Pereira, Fabiola Lima
    Nogueira de Goes, Fernanda dos Santos
    Monti Fonseca, Luciana Mara
    Silvan Scochi, Carmen Gracinda
    Castral, Thaila Correa
    Leite, Adriana Moraes
    [J]. REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2013, 47 (06) : 1272 - 1278