Non-Contact Automatic Vital Signs Monitoring of Infants in a Neonatal Intensive Care Unit Based on Neural Networks

被引:26
|
作者
Khanam, Fatema-Tuz-Zohra [1 ]
Perera, Asanka G. [1 ]
Al-Naji, Ali [1 ,2 ]
Gibson, Kim [3 ]
Chahl, Javaan [1 ]
机构
[1] Univ South Australia, UniSA STEM, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[2] Middle Tech Univ, Elect Engn Tech Coll, Baghdad 10022, Iraq
[3] Univ South Australia, Clin & Hlth Sci, City East Campus,North Terrace, Adelaide, SA 5000, Australia
关键词
heart rate; respiratory rate; NICU; convolutional neural network; signal decomposition; EMPIRICAL MODE DECOMPOSITION; HEART-RATE; ARTIFACT REMOVAL; TECHNOLOGY;
D O I
10.3390/jimaging7080122
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Infants with fragile skin are patients who would benefit from non-contact vital sign monitoring due to the avoidance of potentially harmful adhesive electrodes and cables. Non-contact vital signs monitoring has been studied in clinical settings in recent decades. However, studies on infants in the Neonatal Intensive Care Unit (NICU) are still limited. Therefore, we conducted a single-center study to remotely monitor the heart rate (HR) and respiratory rate (RR) of seven infants in NICU using a digital camera. The region of interest (ROI) was automatically selected using a convolutional neural network and signal decomposition was used to minimize the noise artefacts. The experimental results have been validated with the reference data obtained from an ECG monitor. They showed a strong correlation using the Pearson correlation coefficients (PCC) of 0.9864 and 0.9453 for HR and RR, respectively, and a lower error rate with RMSE 2.23 beats/min and 2.69 breaths/min between measured data and reference data. A Bland-Altman analysis of the data also presented a close correlation between measured data and reference data for both HR and RR. Therefore, this technique may be applicable in clinical environments as an economical, non-contact, and easily deployable monitoring system, and it also represents a potential application in home health monitoring.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Continuous non-contact vital sign monitoring in neonatal intensive care unit
    Villarroel, Mauricio
    Guazzi, Alessandro
    Jorge, Joao
    Davis, Sara
    Watkinson, Peter
    Green, Gabrielle
    Shenvi, Asha
    McCormick, Kenny
    Tarassenko, Lionel
    [J]. HEALTHCARE TECHNOLOGY LETTERS, 2014, 1 (03) : 87 - 91
  • [2] Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit
    Villarroel, Mauricio
    Chaichulee, Sitthichok
    Jorge, Joao
    Davis, Sara
    Green, Gabrielle
    Arteta, Carlos
    Zisserman, Andrew
    McCormick, Kenny
    Watkinson, Peter
    Tarassenko, Lionel
    [J]. NPJ DIGITAL MEDICINE, 2019, 2 (1)
  • [3] Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit
    Mauricio Villarroel
    Sitthichok Chaichulee
    João Jorge
    Sara Davis
    Gabrielle Green
    Carlos Arteta
    Andrew Zisserman
    Kenny McCormick
    Peter Watkinson
    Lionel Tarassenko
    [J]. npj Digital Medicine, 2
  • [4] Non-contact monitoring of respiration in the neonatal intensive care unit
    Jorge, Joao
    Villarroel, Mauricio
    Chaichulee, Sitthichok
    Guazzi, Alessandro
    Davis, Sara
    Green, Gabrielle
    McCormick, Kenny
    Tarassenko, Lionel
    [J]. 2017 12TH IEEE INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION (FG 2017), 2017, : 286 - 293
  • [5] Non-Contact Vital-Sign Monitoring System for Premature Infants in Neonatal Intensive Care Units
    Foldesy, Peter
    Janoki, Imre
    Zarandy, Akos
    Pazmany, Peter
    [J]. ERCIM NEWS, 2020, (122): : 50 - 51
  • [6] Non-contact vital signs monitoring in broiler chickens
    Hossain, Md. Shafkat
    Pramanik, Sourav Kumar
    Rahman, Atikur
    Ali, Shahin
    Islam, Shekh Md Mahmudul
    [J]. JOURNAL OF ENGINEERING-JOE, 2023, 2023 (11):
  • [7] Non-Contact Heart Rate Monitoring in Neonatal Intensive Care Unit using RGB Camera
    Chen, Qiong
    Jiang, Xinyu
    Liu, Xiangyu
    Lu, Chunmei
    Wang, Laishuan
    Chen, Wei
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5822 - 5825
  • [8] Development of a baby friendly non-contact method for measuring vital signs: first results of clinical measurements in an open incubator at a Neonatal Intensive Care Unit
    Klaessens, John H. G. M.
    van den Born, Marlies
    van der Veen, Albert
    Sikkens-van de Kraats, Janine
    van den Dungen, Frank A. M.
    Verdaasdonk, Rudolf M.
    [J]. ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XII, 2014, 8935
  • [9] Non-contact vital sign monitoring of patients in an intensive care unit: A human factors analysis of staff expectations
    Ede, Jody
    Vollam, Sarah
    Darbyshire, Julie L.
    Gibson, Oliver
    Tarassenko, Lionel
    Watkinson, Peter
    [J]. APPLIED ERGONOMICS, 2021, 90
  • [10] Non-contact automatic vital signs monitoring of neonates in NICU using video camera imaging
    Khanam, Fatema-Tuz-Zohra
    Al-Naji, Ali
    Perera, Asanka G.
    Gibson, Kim
    Chahl, Javaan
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (02): : 278 - 285