Characterization of a confocal microscope for time-resolved photon counting fluorescence

被引:0
|
作者
Schoutteten L. [1 ]
Denjean P. [1 ]
Pansu R.B. [1 ]
机构
[1] ENS Cachan, PPSM (Photophysique et Photochimie Supramoléculaires et Macromoléculaires), URA 1906 CNRS, 94235 Cachan Cedex
关键词
Anisotropy; Calcium probes; Confocal microscopy; Fluorescence correlation spectroscopy; Laser; Time-resolved fluorescence;
D O I
10.1007/BF02760507
中图分类号
学科分类号
摘要
A confocal microscope setup is developed for time-resolved fluorescence measurements. It is added to a traditional cuvette time-resolved setup, with a pumped Ti-Sa light source. The temporal resolution of 37 ps (FWHM) is not degraded, in comparison with the cuvette setup also described. These setups allow both decay lifetime and anisotropy relaxation time determination. Fluorescence correlation spectroscopy (FCS) is used to determine the observation point size. When associated with the calcium probe calcium green, calcium concentration in single cells can be determined in 10 ms by simultaneous acquisition of early and late fluorescence photons. © 1997 Plenum Publishing Corporation.
引用
收藏
页码:155 / 165
页数:10
相关论文
共 50 条
  • [1] A TIME-RESOLVED FLUORESCENCE MICROSCOPE
    FRENCH, T
    SO, P
    BERLAND, K
    GRATTON, E
    [J]. BIOPHYSICAL JOURNAL, 1993, 64 (02) : A110 - A110
  • [2] TIME-RESOLVED FLUORESCENCE MICROSCOPY USING MULTICHANNEL PHOTON-COUNTING
    WANG, XF
    KITAJIMA, S
    UCHIDA, T
    COLEMAN, DM
    MINAMI, S
    [J]. APPLIED SPECTROSCOPY, 1990, 44 (01) : 25 - 30
  • [3] Development of intracellular calcium measurement by time-resolved photon-counting fluorescence
    Schoutteten, L
    Denjean, P
    Joliff-Botrel, G
    Bernard, C
    Pansu, D
    Pansu, RB
    [J]. PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1999, 70 (05) : 701 - 709
  • [4] The Role of the Photon Counting Loss Effect in Time-Resolved Measurements of Fluorescence Anisotropy
    Gvozdev, Daniil A.
    Semenov, Alexey N.
    Tsoraev, Georgy V.
    Maksimov, Eugene G.
    [J]. PHOTONICS, 2023, 10 (06)
  • [5] CIRCUIT FOR TIME-RESOLVED PHOTON-COUNTING
    KYLE, TG
    CLEMENTS, WE
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (12): : 1790 - 1792
  • [6] Time-resolved photon counting with digital oscilloscope
    Stacewicz, T
    KrainskaMiszczak, M
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (04) : 453 - 455
  • [7] MICROVOLUME TIME-RESOLVED FLUORESCENCE SPECTROSCOPY USING A CONFOCAL SYNCHROTRON-RADIATION MICROSCOPE
    VANDEROORD, CJR
    GERRITSEN, HC
    ROMMERTS, FFG
    SHAW, DA
    MUNRO, IH
    LEVINE, YK
    [J]. APPLIED SPECTROSCOPY, 1995, 49 (10) : 1469 - 1473
  • [8] Confocal time-resolved fluorescence anisotropy imaging
    Bader, Arjen N.
    Hofman, Erik G.
    Henegouwen, Paul van Bergen en
    Gerritsen, Hans C.
    [J]. IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES V, 2007, 6441
  • [9] A versatile time-resolved laser scanning confocal microscope
    Eigenbrot, IV
    Crystall, B
    Phillips, D
    [J]. FLUORESCENCE MICROSCOPY AND FLUORESCENT PROBES, 1996, : 79 - 83
  • [10] Time-autocorrelated two-photon counting technique for time-resolved fluorescence measurements
    Borst, WL
    Liu, LI
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 41 - 49