Compressively Sampled MR Image Reconstruction Using Hyperbolic Tangent-Based Soft-Thresholding

被引:0
|
作者
Jawad Shah
I. M. Qureshi
Julio Proano
Yiming Deng
机构
[1] University of Colorado Denver and Anschutz Medical Campus,Department of Electrical Engineering
[2] Air University,Department of Electrical Engineering, Institute of Signals, Systems and Soft computing (ISSS)
来源
Applied Magnetic Resonance | 2015年 / 46卷
关键词
Phantom Image; Recovered Image; Thresholding Function; Iterative Thresholding Algorithm; Original Magnetic Resonance Image;
D O I
暂无
中图分类号
学科分类号
摘要
The application of compressed sensing (CS) to magnetic resonance (MR) images utilizes the transformed domain sparsity to enable the reconstruction from an under-sampled k-space (Fourier) data using a non-linear recovery algorithm. In order to estimate the missing k-space data from the partial Fourier samples, the reconstruction algorithms minimize an objective function based on mixed l1 − l2 norms. Iterative-shrinkage algorithms, such as parallel coordinate descent (PCD) and separable surrogate functional, provide an efficient numerical technique to minimize the l1-regularized least square optimization problem. These algorithms require a thresholding step to induce sparsity in the solution, which is an essential requirement of the CS recovery. This paper introduces a novel soft-thresholding method based on the hyperbolic tangent function. It has been shown that by using the proposed thresholding function in the sparsifying domain and a data consistency step in the k-space, the iterative-shrinkage algorithms can be used effectively to recover the under-sampled MR images. For the purpose of demonstration, we use the proposed soft-thresholding and data consistency with the PCD algorithm and compare its performance with the conventional PCD, projection onto convex sets and low-resolution reconstruction methods. The metrics used to compare the various algorithms are the artifact power, the peak signal-to-noise ratio, the correlation and the structural similarity index. The experimental results are validated using Shepp–Logan phantom image as well as real human head MR images taken from the MRI scanner at St. Mary’s Hospital, London.
引用
收藏
页码:837 / 851
页数:14
相关论文
共 50 条
  • [21] Fuzzy wavelets based color image compression/reconstruction with soft thresholding
    Nobuhara, H
    Hirota, K
    PROCEEDINGS OF THE SIXTH IASTED INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING, 2004, : 193 - 198
  • [22] MR image reconstruction from sparsely sampled scans based on Multilayer Perceptrons and using regularization techniques
    Karras, DA
    Reczko, M
    Mertzios, BG
    Graveron-Demilly, D
    van Ormondt, D
    IJCNN 2000: PROCEEDINGS OF THE IEEE-INNS-ENNS INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOL I, 2000, : 336 - 341
  • [23] Respiratory motion-corrected, compressively sampled dynamic MR image reconstruction by exploiting multiple sparsity constraints and phase correlation-based data binning
    Faisal Najeeb
    Muhammad Usman
    Ibtisam Aslam
    Sohaib A. Qazi
    Hammad Omer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 411 - 419
  • [24] Respiratory motion-corrected, compressively sampled dynamic MR image reconstruction by exploiting multiple sparsity constraints and phase correlation-based data binning
    Najeeb, Faisal
    Usman, Muhammad
    Aslam, Ibtisam
    Qazi, Sohaib A.
    Omer, Hammad
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (03) : 411 - 419
  • [25] ECG Noise Reduction Using Empirical Mode Decomposition Based on Combination of Instantaneous Half Period and Soft-Thresholding
    Samadi, Shamim
    Shamsollahi, Mohammad B.
    2014 MIDDLE EAST CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2014, : 244 - 248
  • [26] Golden-Angle Radial Sparse Parallel MR Image Reconstruction Using SC-GROG Followed by Iterative Soft Thresholding
    Shahzadi, Iram
    Aslam, Ibtisam
    Qazi, Sohaib Ayyaz
    Omer, Hammad
    APPLIED MAGNETIC RESONANCE, 2019, 50 (08) : 977 - 988
  • [27] Golden-Angle Radial Sparse Parallel MR Image Reconstruction Using SC-GROG Followed by Iterative Soft Thresholding
    Iram Shahzadi
    Ibtisam Aslam
    Sohaib Ayyaz Qazi
    Hammad Omer
    Applied Magnetic Resonance, 2019, 50 : 977 - 988
  • [28] Fast Parallel MR Image Reconstruction via B1-Based, Adaptive Restart, Iterative Soft Thresholding Algorithms (BARISTA)
    Muckley, Matthew J.
    Noll, Douglas C.
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 578 - 588
  • [29] Improved MR image reconstruction from sparsely sampled scans based on neural networks
    Reczko, M
    Karras, DA
    Mertzios, BG
    Graveron-Demilly, D
    van Ormondt, D
    PATTERN RECOGNITION LETTERS, 2001, 22 (01) : 35 - 46
  • [30] Transfer learning in deep neural network based under-sampled MR image reconstruction
    Arshad, Madiha
    Qureshi, Mahmood
    Inam, Omair
    Omer, Hammad
    MAGNETIC RESONANCE IMAGING, 2021, 76 : 96 - 107