Comparative Evaluation of Implants with Different Surface Treatments Placed in Human Edentulous Mandibles: A 1-Year Prospective Study

被引:0
|
作者
Fernando P. S. Guastaldi
Thallita P. Queiroz
Daniela O. Marques
Anne B. S. Santos
Rafael S. Molon
Rogerio Margonar
Antonio C. Guastaldi
机构
[1] São Paulo State University (Unesp),Department of Diagnosis and Surgery, School of Dentistry
[2] Harvard School of Dental Medicine,Skeletal Biology Research Center, Department of Oral and Maxillofacial Surgery, Massachusetts General Hospital
[3] Thier Research Building,Department of Health Sciences
[4] University Center of Araraquara (UNIARA),Department of Physical Chemistry, Institute of Chemistry
[5] São Paulo State University (Unesp),undefined
关键词
Dental implants; Imaging; Lasers; Resonance frequency analysis; Surface;
D O I
暂无
中图分类号
学科分类号
摘要
The aims of this study were to analyze prospectively and comparatively the peri-implant bone crest levels, bone density, stability and success rate of implants with different surface treatments in human edentulous mandibles. Twenty edentulous patients were selected. Four different implants were placed between the mental foramen. Four groups were evaluated: (1) laser-modified surface (LASER), (2) surface modified by laser with deposition of apatites (LASER + HA), (3) surface modified by double acid etching (ACID, Implacil De Bortoli) and (4) surface modified by sandblasting and acid etching (SLActive®, Straumann). Clinical, radiographic, resonance frequency and tomographic analyses were used. After 4 months, mandibular fixed implant prostheses were installed. Clinical and radiographic analyses were performed at times T0 (immediately after implant placement), T1 (15 days), T2 (30 days), T3 (60 days), T4 (90 days), T5 (120 days), T6 (180 days) and T7 (360 days), post-implant placement. The resonance frequency analysis (RFA) was measured at T0, T4, T6 and T7. The tomographic analysis was performed at T0, T4 and T7. In the radiographic bone density analysis, a statistical difference was found between the SLActive® and LASER + HA groups at T4 (p < 0.05). Statistical differences were observed in RFA at T4 (90 days), between the SLActive® and LASER groups (p < 0.05) and between the SLActive® and LASER + HA groups (p < 0.05). At T6 and T7, statistical differences were found between the SLActive® group and all other implant surfaces (p < 0.01). The experimental surfaces analyzed showed encouraging positive outcomes compared to those of the SLActive® surface. Long-term follow-up should be performed to confirm these results.
引用
收藏
页码:815 / 823
页数:8
相关论文
共 50 条
  • [1] Comparative Evaluation of Implants with Different Surface Treatments Placed in Human Edentulous Mandibles: A 1-Year Prospective Study
    Guastaldi, Fernando P. S.
    Queiroz, Thallita P.
    Marques, Daniela O.
    Santos, Anne B. S.
    Molon, Rafael S.
    Margonar, Rogerio
    Guastaldi, Antonio C.
    [J]. JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2022, 21 (03): : 815 - 823
  • [2] A prospective clinical study of three different endosseous implants in edentulous mandibles
    Roynesdal, AK
    Haanes, HR
    Ambjornsen, E
    Stovne, S
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 : 89 - 89
  • [3] A comparative clinical study of three different endosseous implants in edentulous mandibles
    Roynesdal, AK
    Ambjornsen, E
    Stovne, S
    Haanaes, HR
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (04) : 500 - 505
  • [4] Immediate Occlusal Loading of Immediately Placed Implants Supporting Fixed Restorations in Completely Edentulous Arches: A 1-Year Prospective Pilot Study
    Pieri, Francesco
    Aldini, Nicolo Nicoli
    Fini, Milena
    Corinaldesi, Giuseppe
    [J]. JOURNAL OF PERIODONTOLOGY, 2009, 80 (03) : 411 - 421
  • [5] A prospective evaluation of Frialoc® implants with ball-abutments in the edentulous mandible:: 1-year results
    Cune, MS
    Verhoeven, JW
    Meijer, GJ
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) : 167 - 173
  • [6] A 5-year prospective multicenter study on 1-stage smooth-surface Branemark System implants with early loading in edentulous mandibles
    Friberg, Bertil
    Raghoebar, Gerry M.
    Grunert, Ingrid
    Hobkirk, John A.
    Tepper, Gabor
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (03) : 481 - 486
  • [7] Early functional loading at 5 days for Branemark implants placed into edentulous mandibles: A prospective, open-ended, longitudinal study
    Becker, W
    Becker, BE
    Huffstetler, S
    [J]. JOURNAL OF PERIODONTOLOGY, 2003, 74 (05) : 695 - 702
  • [8] Rehabilitation of edentulous mandibles by means of five TiUnite™ implants after one-stage surgery:: A 1-year retrospective study of 90 patients
    Friberg, Bertil
    Jemt, Torsten
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (01) : 47 - 54
  • [9] Immediate functional loading of implants placed with flapless surgery in the edentulous maxilla: 1-year follow-up of a single cohort study
    Cannizzaro, Gioacchino
    Leone, Michele
    Esposito, Marco
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (01) : 87 - 95
  • [10] Rehabilitation of edentulous mandibles by means of turned Branemark System® implants after one-stage surgery:: A 1-year retrospective study of 152 patients
    Friberg, B
    Henningsson, C
    Jemt, T
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 (01) : 1 - 9