Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system

被引:0
|
作者
Oluwatosin O. Dada
Lauren M. Ramsay
Jane A. Dickerson
Nathan Cermak
Rong Jiang
Cuiru Zhu
Norman J. Dovichi
机构
[1] University of Washington,Chemistry Department
[2] University of Alberta,Chemistry Department
[3] Midwest Energy Group,undefined
[4] INC,undefined
[5] Great Southern Laboratories,undefined
来源
关键词
Capillary electrophoresis/electrophoresis; Fluorescence/luminescence; Bioanalytical methods; Spectroscopy/instrumentation;
D O I
暂无
中图分类号
学科分类号
摘要
We report a multiplexed capillary electrophoresis system employing an array of 32 capillaries with a micromachined sheath-flow cuvette as the detection chamber. The sample streams were simultaneously excited with a 473-nm laser beam, and the fluorescence emission was imaged on a CCD camera with a pair of doublet achromat lens. The instrument produced mass detection limits of 380 ± 120 yoctomoles for fluorescein in zone electrophoresis. Capillary isoelectric focusing of fluorescent standards produced peaks with an average width of 0.0029 ± 0.0008 pH. Capillary coating stability limits the reproducibility of the analysis.
引用
收藏
页码:3305 / 3310
页数:5
相关论文
共 50 条
  • [21] Acousto-optical deflection-based whole channel scanning for microchip isoelectric focusing with laser-induced fluorescence detection
    Sanders, JC
    Huang, ZL
    Landers, JP
    LAB ON A CHIP, 2001, 1 (02) : 167 - 172
  • [22] Dynamic pH junction-sweeping for on-line focusing of dipeptides in capillary electrophoresis with laser-induced fluorescence detection
    Chen, Ying
    Zhang, Lan
    Cai, Zongwei
    Chen, Guonan
    ANALYST, 2011, 136 (09) : 1852 - 1858
  • [23] Coupling of solid-phase microextraction and capillary isoelectric focusing with laser-induced fluorescence whole column imaging detection for protein analysis
    Liu, Z
    Pawliszyn, J
    ANALYTICAL CHEMISTRY, 2005, 77 (01) : 165 - 171
  • [24] Design and evaluation of capillary array electrophoresis with 532 mn laser-induced fluorescence detection
    Liu Kai-Ying
    Wang Jun
    Wang Hui
    Bai Jing-Ling
    Wang Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (05) : 772 - 774
  • [25] Comprehensive two-dimensional separation system by coupling capillary reverse-phase liquid chromatography to capillary isoelectric focusing for peptide and protein mapping with laser-induced fluorescence detection
    Mao, Y
    Zhang, XM
    ELECTROPHORESIS, 2003, 24 (18) : 3289 - 3295
  • [26] Characterization of humic substances using capillary electrophoresis with photodiode array and laser-induced fluorescence detection
    Norden, M
    DabekZlotorzynska, E
    ELECTROPHORESIS, 1997, 18 (02) : 292 - 299
  • [27] Characterization of humic substances using capillary electrophoresis with photodiode array and laser-induced fluorescence detection
    Analysis and Methods Division, Environmental Technology Centre, Environment Canada, Ottawa, Ont., Canada
    不详
    不详
    ELECTROPHORESIS, 2 (292-299):
  • [28] Novel multi-channel confocal laser-induced fluorescence detection system
    Li, Hui
    Wang, Li-Qiang
    Shi, Yan
    Shangguan, Wang-Pin
    Yan, Hui-Min
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2010, 39 (05): : 905 - 909
  • [29] On-line focusing of flavin derivatives using dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection
    Britz-McKibbin, P
    Otsuka, K
    Terabe, S
    ANALYTICAL CHEMISTRY, 2002, 74 (15) : 3736 - 3743
  • [30] Steroid profiles determined by capillary electrochromatography, laser-induced fluorescence detection and electrospray-mass spectrometry
    Que, AH
    Palm, A
    Baker, AG
    Novotny, MV
    JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 379 - 391