Amperometric Detection of Dopamine in the Presence of Ascorbic Acid Using a Nafion Coated Glassy Carbon Electrode Modified with Catechin Hydrate as a Natural Antioxidant

被引:0
|
作者
Abdollah Salimi
Kamaleddin Abdi
Gholam-Reza Khayatian
机构
[1] Department of Chemistry,
[2] Faculty of Science,undefined
[3] Kurdistan University,undefined
[4] Sanandaj,undefined
[5] Iran,undefined
来源
Microchimica Acta | 2004年 / 144卷
关键词
Key words: Modified electrode; catechin-hydrate; dopamine; ascorbic acid; glassy carbon; nafion; amperommetery.;
D O I
暂无
中图分类号
学科分类号
摘要
Catechin hydrate (trans-3,3′,4′,5,7-penta-hydroxyflavone) is a derivative of catechol, and it is one of the natural antioxidant and anticarcinogenic compounds found in many fruits and agricultural foods. A new electrode was prepared by electrodeposition of a catechin-hydrate film on the surface of an activated glassy carbon electrode, followed by coating with nafion layer. Cyclic voltammetry was used for the deposition process, and the resulting modified electrode was found to retain the activity of the quinone/hydroquinone group anticipated for a surface-immobilized redox couple. The cyclic voltammograms of the modified electrode indicated that the surface-confined catechin-hydrate was strongly dependent on the solution pH. The electrochemical behaviour and stability of the modified electrode were studied by cyclic voltammetry. The apparent charge transfer rate constant (ks) and electron transfer coefficient (α) between the electrode surface and adsorbed catechin hydrate were calculated as 0.41 and 0.31 sz−1 0.31, respectively. The modified electrode exhibits an electrocatalytic effect on dopamine oxidation in the pH range of 2 to 7. The modified electrode was used for the electrocatalytic oxidation of dopamine in the presence of ascorbic acid and the elimination of the interference by ascorbic acid (AA) when present in a 200-fold concentration excess. A very large decrease (400 mV) in the overpotential for the oxidation of dopamine and current increase were observed on the surface of the modified electrode. Dopamine was determined amperometrically at the modified electrode in the concentration range of 100 nM to 0.1 mM. The detection limit (signal to noise is 3) and sensitivity are 11 nM and 16 nA/µM, respectively. The modified electrode was employed to determine DA in biological mediums.
引用
下载
收藏
页码:161 / 169
页数:8
相关论文
共 50 条
  • [31] The determination of dopamine in the presence of ascorbic acid at the modified glassy carbon electrode with phytic acid and single-walled carbon nanotubes
    Bae, Si Ra
    Jeong, Haesang
    Jo, Suhee
    Jeon, Seungwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2007, 28 (12): : 2363 - 2368
  • [32] The determination of dopamine in the presence of ascorbic acid at the modified glassy carbon electrode with phytic acid and single-walled carbon nanotubes
    Department of Chemistry, Institute of Basic Science, Chonnam National University, Gwangju 500-757, Korea, Republic of
    Bull. Korean Chem. Soc., 2007, 12 (2363-2368):
  • [33] Solar graphene modified glassy carbon electrode for the voltammetric resolution and detection of dopamine, ascorbic acid and uric acid
    Nancy, T. E. Mary
    Anithakumary, V.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 720 : 107 - 114
  • [34] Determination of Acetaminophen in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Poly(Caffeic acid)
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Cetintas, Gamze
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (01): : 148 - 160
  • [35] Selective determination of dopamine in the presence of ascorbic acid using ferrocenyl-tethered PAMAM dendrimers modified glassy carbon electrode
    Chen, Quanpeng
    Ai, Shiyun
    Ma, Qiang
    Yin, Huanshun
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1379 - 1385
  • [36] Selective determination of dopamine in the presence of ascorbic acid using ferrocenyl-tethered PAMAM dendrimers modified glassy carbon electrode
    Quanpeng Chen
    Shiyun Ai
    Qiang Ma
    Huanshun Yin
    Journal of Applied Electrochemistry, 2010, 40 : 1379 - 1385
  • [37] Selective Determination of Epinephrine in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Graphene
    Li, Xia
    Chen, Meifeng
    Ma, Xinying
    ANALYTICAL SCIENCES, 2012, 28 (02) : 147 - 151
  • [38] Selective Determination of Epinephrine in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Graphene
    Xia Li
    Meifeng Chen
    Xinying Ma
    Analytical Sciences, 2012, 28 : 147 - 151
  • [39] Electrochemical detection of dopamine using a modified glassy carbon electrode
    Correa, Jaime
    Wang, Tingting
    Heineman, William R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [40] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927