Stereo-DIC Calibration and Speckle Image Generator Based on FE Formulations

被引:0
|
作者
R. Balcaen
L. Wittevrongel
P. L. Reu
P. Lava
D. Debruyne
机构
[1] KU Leuven,
[2] Department of Materials Technology,undefined
[3] MatchID,undefined
[4] Sandia National Laboratories,undefined
来源
Experimental Mechanics | 2017年 / 57卷
关键词
Digital image correlation; Uncertainty quantification; Calibration; Optical techniques;
D O I
暂无
中图分类号
学科分类号
摘要
Stereo digital image correlation (stereo-DIC) is being accepted by the industry as a valid full-field measurement technique for measuring shape, motion and deformation, and it is therefore of utmost importance to provide uncertainties on the obtained measurements. However, the influences on a stereo-DIC measurement are not fully understood; indeed, stereo-DIC is a complex optical-numerical process and it is not always clear how errors are propagating throughout the measurement chain. In order to investigate the magnitude of the different error-sources a simulator for stereo-DIC is proposed. This simulator is able to generate realistic synthetic images as if they were made during a real set-up, so the error sources can be investigated separately and an optimal set-up can be chosen before any physical test is performed. We present in this paper the mathematical approach to the DIC simulator including details on how to convert FE displacement field results to stereo-DIC images. The simulator includes the ability to control the lighting and to create synthetic calibration images. The synthetic images are compared to simulations for a bulge test as a validation of the simulator. Synthetic calibration images are compared to experimental calibration studies to verify those. Finally a brief look at how the simulator could be used for looking at calibration quality is conducted.
引用
收藏
页码:703 / 718
页数:15
相关论文
共 32 条
  • [21] A stereo camera self-calibration method using DIC-based planar feature matching
    Ji, Yifan
    Yin, Wei
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS IX, 2022, 12319
  • [22] FPGA-based Image Analyzer for Calibration of Stereo Vision Rigs
    Mielczarek, Aleksander
    Makowski, Dariusz
    Perek, Piotr
    Napieralski, Andrzej
    Sztoch, Przemyslaw
    2016 IEEE-NPSS REAL TIME CONFERENCE (RT), 2016,
  • [23] Calibrating stereo-digital image correlation system using synthetic speckle-pattern calibration target
    Chen, Bin
    Liu, Haibo
    Pan, Bing
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (09)
  • [24] Evaluation of a low-cost approach to 2-D digital image correlation vs. a commercial stereo-DIC system in Brazilian testing of soil specimens
    Arza-Garcia, M.
    Nunez-Temes, C.
    Lorenzana, J. A.
    Ortiz-Sanz, J.
    Castro, A.
    Portela-Barral, M.
    Gil-Docampo, M.
    Bastos, G.
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2021, 22 (01)
  • [25] DIC measurement method based on binocular stereo vision for image 3D displacement detection
    Dong, Xue
    JOURNAL OF MEASUREMENTS IN ENGINEERING, 2023, 11 (04) : 437 - 452
  • [26] Bi-prism-based single-bilateral-telecentric-camera stereo-DIC for accurate underwater 3D deformation measurement: Implementation of a parametric model
    Luo, Haojian
    Yu, Liping
    Pan, Bing
    OPTICS AND LASERS IN ENGINEERING, 2023, 162
  • [28] Calibration of stereo-digital image correlation for large field of view measurement based on photogrammetry
    Shao, Xinxing
    Wei, Kang
    He, Xiaoyuan
    OPTICS AND LASERS IN ENGINEERING, 2023, 169
  • [29] A novel global calibration method for vision measurement system based on mirror-image stereo target
    Zhang, Wanning
    Zhou, Fuqiang
    Liu, Yang
    Yang, Lemiao
    MEASUREMENT, 2024, 230
  • [30] Target-based calibration method for multifields of view measurement using multiple stereo digital image correlation systems
    Dong, Shuai
    Yu, Shanshan
    Huang, Zheng
    Song, Shoutan
    Shao, Xinxing
    Kang, Xin
    He, Xiaoyuan
    OPTICAL ENGINEERING, 2017, 56 (12)