Automated in situ trace element analysis of silicate materials by laser ablation inductively coupled plasma mass spectrometry

被引:0
|
作者
Zhongxing Chen
Dante Canil
Henry P. Longerich
机构
[1] School of Earth and Ocean Sciences,
[2] University of Victoria,undefined
[3] PO Box 3055,undefined
[4] Victoria,undefined
[5] BC Canada V8W 3P6 e-mail: Zhongxing.Chen@usm.edu,undefined
[6] Department of Earth Sciences and Centre for Earth Resources Research,undefined
[7] Memorial University of Newfoundland,undefined
[8] St. John’s,undefined
[9] Newfoundland,undefined
[10] Canada A1B 3X5,undefined
关键词
Inductively Couple Plasma Mass Spectrometry; Laser Ablation; External Calibration; Trace Element Analysis; Transport Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes the automated in situ trace element analysis of solid materials by laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS). A compact computer-controlled solid state Nd:YAG MerchantekTM EO UV laser ablation (LA) system has been coupled with the high sensitivity VG PQII S ICP-MS. A two-directional communication was interfaced in-house between the ICP-MS and the LA via serial RS-232 port. Each LA-ICP-MS analysis at a defined point includes a 60 s pre-ablation delay, a 60 s ablation, and a 90 s flush delay. The execution of each defined time setting by LA was corresponding to the ICP-MS data acquisition allowing samples to be run in automated cycle sequences like solution auto-sampler ICP-MS analysis. Each analytical cycle consists of four standards, one control reference material, and 15 samples, and requires about 70 min. Data produced by Time Resolved Analysis (TRA) from ICP-MS were later reduced off-line by in-house written software. Twenty-two trace elements from four reference materials (NIST SRM 613, and fused glass chips of BCR-2, SY-4, and G-2) were determined by the automated LA-ICP-MS method. NIST SRM 610 or NIST SRM 613 was used as an external calibration standard, and Ca as an internal standard to correct for drift, differences in transport efficiency and sampling yield. Except for Zr and Hf in G-2, relative standard deviations for all other elements are less than 10%. Results compare well with the data reported from literature with average limits of detection from 1 ng g–1 to 455 ng g–1 and less than 100 ng g–1 for most trace elements.
引用
收藏
页码:73 / 78
页数:5
相关论文
共 50 条
  • [21] Quantitative analysis of trace element abundances in glasses and minerals: a comparison of laser ablation inductively coupled plasma mass spectrometry, solution inductively coupled plasma mass spectrometry, proton microprobe and electron microprobe data
    Norman, MD
    Griffin, WL
    Pearson, NJ
    Garcia, MO
    O'Reilly, SY
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) : 477 - 482
  • [22] Control of the composition of lanthanum gallium silicate by laser ablation inductively coupled plasma mass spectrometry
    V. A. Khvostikov
    V. K. Karandashev
    Zh. P. Burmii
    O. A. Buzanov
    Journal of Analytical Chemistry, 2014, 69 : 495 - 501
  • [23] Control of the composition of lanthanum gallium silicate by laser ablation inductively coupled plasma mass spectrometry
    Khvostikov, V. A.
    Karandashev, V. K.
    Burmii, Zh. P.
    Buzanov, O. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (05) : 495 - 501
  • [24] Multi-element analysis of compost by laser ablation-inductively coupled plasma mass spectrometry
    Jimenez, Maria S.
    Gomez, Maria T.
    Castillo, Juan R.
    TALANTA, 2007, 72 (03) : 1141 - 1148
  • [25] Trace element analysis of scheelite by excimer laser ablation inductively coupled plasma mass spectrometry (ELA-ICP-MS) using a synthetic silicate glass standard
    Sylvester, PJ
    Ghaderi, M
    CHEMICAL GEOLOGY, 1997, 141 (1-2) : 49 - 65
  • [26] Trace element characteristics in the diopsides of peridotite xenoliths: a laser ablation inductively coupled plasma-mass spectrometry study
    Chen, SH
    Zhou, XH
    O'Reilly, SY
    Griffin, WL
    Zhang, GH
    Zhang, M
    CHINESE SCIENCE BULLETIN, 1998, 43 (07): : 579 - 583
  • [27] Spatially resolved and bulk trace element analysis by laser ablation - inductively coupled plasma - mass spectrometry (LA-ICP-MS)
    Petrelli, Maurizio
    Perugini, Diego
    Alagna, Kelgan E.
    Poli, Giampiero
    Peccerillo, Angelo
    PERIODICO DI MINERALOGIA, 2008, 77 (01): : 3 - 21
  • [28] Trace element analysis of NIST SRM 614 and 616 glass reference materials by laser ablation microprobe-inductively coupled plasma-mass spectrometry
    Kurosawa, M
    Jackson, SE
    Sueno, S
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2002, 26 (01): : 75 - 84
  • [29] Analysis of α-alumina samples by mass spectrometry with inductively coupled plasma and laser ablation
    Khvostikov, V. A.
    Karandashev, V. K.
    Burmii, Zh. P.
    INORGANIC MATERIALS, 2015, 51 (14) : 1410 - 1415
  • [30] Analysis of α-alumina samples by mass spectrometry with inductively coupled plasma and laser ablation
    V. A. Khvostikov
    V. K. Karandashev
    Zh. P. Burmii
    Inorganic Materials, 2015, 51 : 1410 - 1415