Applicability of data-driven respiratory motion correction to CZT SPECT myocardial perfusion imaging in the clinical setting: The birth of an old wish

被引:0
|
作者
Doumit Daou
Remy Sabbah
Carlos Coaguila
Hatem Boulahdour
机构
[1] Cochin University Hospital,Nuclear Medicine
[2] CHRU de Besançon,Nuclear Medicine
[3] Centre Hospitalier de Bigorre,Nuclear Medicine
[4] EA 7334 REMES,undefined
[5] Université Paris-Diderot,undefined
[6] Sorbonne Paris-Cité,undefined
来源
关键词
Myocardial Perfusion Imaging (MPI); Cardiac RM; Percutaneous Transluminal Coronary Angioplasty; Myoview; Exercise Stress Test;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1451 / 1453
页数:2
相关论文
共 50 条
  • [1] Applicability of data-driven respiratory motion correction to CZT SPECT myocardial perfusion imaging in the clinical setting: The birth of an old wish
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulahdour, Hatem
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1451 - 1453
  • [2] Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study
    Doumit Daou
    Rémy Sabbah
    Carlos Coaguila
    Hatem Boulahdour
    [J]. Journal of Nuclear Cardiology, 2017, 24 : 1598 - 1607
  • [3] Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulahdour, Hatem
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (05) : 1598 - 1607
  • [4] Simulation of Patient Motion with Myocardial Perfusion CZT SPECT: Data-Driven Motion Detection and Correction
    Daou, D.
    Sabbah, R.
    Alattar, Y.
    Coaguila, C.
    Boulahdour, H.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S337 - S337
  • [5] Feasibility of Data-Driven Respiratory-Motion Correction of Myocardial Perfusion SPECT with CZT Discovery NM 530c
    Daou, D.
    Sabbah, R.
    Boulandour, H.
    Coaguila, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S246 - S246
  • [6] Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT
    Doumit Daou
    Rémy Sabbah
    Carlos Coaguila
    Hatem Boulahdour
    [J]. Journal of Nuclear Cardiology, 2018, 25 : 1299 - 1309
  • [7] Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulandour, Hatem
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (04) : 1299 - 1309
  • [8] Data-driven respiratory-motion correction of myocardial perfusion SPECT imaging with Discovery NM 530c
    Daou, Doumit
    Sabbah, Remy
    Aladalah, Abdullah
    Monsarrat, Olivier
    Coaguila, Carlos
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [9] Fully-automatic data-driven motion correction improves the diagnostic performance of myocardial perfusion imaging with CZT cameras
    Ko, C.
    Ko, K.
    Yen, R.
    Chen, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S326 - S327
  • [10] Value of respiratory and patient motion correction in myocardial perfusion imaging using a CZT-based SPECT camera
    Van Dijk, Joris
    Dalen, Jorn
    Mouden, Mohamed
    Ottervanger, Jan Paul
    Knollema, Siert
    Slump, Cornelis
    Jager, Pieter
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57