Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT

被引:0
|
作者
Doumit Daou
Rémy Sabbah
Carlos Coaguila
Hatem Boulahdour
机构
[1] Université Paris-Diderot,EA 7334 REMES
[2] Sorbonne Paris-Cité,Nuclear Medicine Department
[3] Cochin University Hospital,Nuclear Medicine Department
[4] AP-HP,Nuclear Medicine Department
[5] CHU Jean Minjoz,undefined
[6] Centre Hospitalier de Bigorre,undefined
来源
关键词
CZT; Respiratory motion; Respiratory gating; Gated SPECT; Myocardial perfusion;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1299 / 1309
页数:10
相关论文
共 50 条
  • [1] Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulandour, Hatem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (04) : 1299 - 1309
  • [2] Data-driven respiratory-motion correction with CZT Discovery NM 530c: impact on extent/severity of myocardial perfusion defects
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulahdour, Hatem
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [3] Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study
    Doumit Daou
    Rémy Sabbah
    Carlos Coaguila
    Hatem Boulahdour
    Journal of Nuclear Cardiology, 2017, 24 : 1598 - 1607
  • [4] Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulahdour, Hatem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (05) : 1598 - 1607
  • [5] Simulation of Patient Motion with Myocardial Perfusion CZT SPECT: Data-Driven Motion Detection and Correction
    Daou, D.
    Sabbah, R.
    Alattar, Y.
    Coaguila, C.
    Boulahdour, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S337 - S337
  • [6] Impact of Data-Driven Respiratory-Motion Correction on the Extent/Severity of Myocardial Perfusion Defects of MPI SPECT Acquired with Discovery NM 530c: REGAT Software
    Daou, D.
    Sabbah, R.
    Bouladhour, H.
    Coaguila, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S230 - S230
  • [7] Applicability of data-driven respiratory motion correction to CZT SPECT myocardial perfusion imaging in the clinical setting: The birth of an old wish
    Doumit Daou
    Remy Sabbah
    Carlos Coaguila
    Hatem Boulahdour
    Journal of Nuclear Cardiology, 2017, 24 : 1451 - 1453
  • [8] Applicability of data-driven respiratory motion correction to CZT SPECT myocardial perfusion imaging in the clinical setting: The birth of an old wish
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulahdour, Hatem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1451 - 1453
  • [9] Feasibility of Data-Driven Respiratory-Motion Correction of Myocardial Perfusion SPECT with CZT Discovery NM 530c
    Daou, D.
    Sabbah, R.
    Boulandour, H.
    Coaguila, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S246 - S246
  • [10] DATA-DRIVEN APPROACH FOR RESPIRATORY MOTION CORRECTION IN CARDIAC SPECT DATA
    Garmendia, Andoni, I
    Yang, Yongyi
    Song, Chao
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1420 - 1423