SIZE-specific dose estimate for lower-limb CT

被引:0
|
作者
Masanao Kobayashi
Yusei Nishihara
Tomonobu Haba
Yuta Matsunaga
Yasuki Asada
Shigeki Kobayashi
机构
[1] Fujita Health University,Graduate School of Medical Sciences
[2] Fujita Health University Hospital,Department of Radiology
[3] Nagoya Kyoritsu Hospital,Department of Imaging
关键词
CT; Monte Carlo simulation; Patient dose; Size-specific dose estimate;
D O I
暂无
中图分类号
学科分类号
摘要
The Computed Tomography Dose Index (CTDI) is an indicator for dose management in computed tomography (CT), but has limited use for patient dosimetry. To evaluate the patient dose, the size-specific dose estimate (SSDE), reported by the American Association of Physics in Medicine task groups 204, 220, and 293, must be calculated by the CTDIvol(z) displayed on the CT console, and the conversion factor f(D(z)) from the effective diameter (DEff) or water equivalent diameter (Dw). However, no reports have verified the appropriateness of using the 320-mm diameter phantom for dose assessment in CT examinations involving the lower limbs. Therefore, we validated a new method for evaluating the SSDE(z) of the lower limbs, using two 160-mm diameter phantoms instead of the 320-mm diameter phantom. The CTDIvol(z) obtained from Monte Carlo (MC) simulation study was reliable because they were almost the same as obtained in a dosimetry study. The conversion factor f (D (zl.l.)) for the lower limbs was evaluated based on the CTDIvol(z) obtained by MC simulation performed using two polymethyl methacrylate cylinder phantoms of 160-mm diameter. The MC simulation was performed by the International Commission on Radiological Protection publication 135 reference adult phantom and was used to evaluate the absorbed dose of the pelvis, thighs, knees, and ankles. The dose showing the greatest difference was the thighs, which was 8.3 mGy (16%) lower than the absorbed dose. Thus, the SSDE (zl.l.) could be estimated from the CTDIvol320z\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{CTDI}}_{\mathrm{vol}}^{320}\left(\mathrm{z}\right)$$\end{document} displayed on the CT scanner console.
引用
收藏
页码:1183 / 1191
页数:8
相关论文
共 50 条
  • [21] Feasibility of Using Size-Specific Dose Estimate (SSDE) to Estimate Effective Dose of Individual Patients
    Abuhaimed, A.
    Martin, C.
    Lee, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [22] DEVELOPMENT OF RADIATION DOSE CALCULATION SOFTWARE USING THE SIZE-SPECIFIC DOSE ESTIMATE
    Shohji, Tomokazu
    Tachibana, Atsushi
    Higuchi, Sousuke
    Nakata, Norio
    Hayashi, Daichi
    Katoh, Yo
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 359 - 369
  • [23] Automated size-specific CT dose monitoring program: Assessing variability in CT dose
    Christianson, Olav
    Li, Xiang
    Frush, Donald
    Samei, Ehsan
    MEDICAL PHYSICS, 2012, 39 (11) : 7131 - 7139
  • [24] PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS
    Mehdipour, Ali
    Parsi, Masoumeh
    Khorram, Faezeh-Sadat
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 176 - 182
  • [25] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Hamza Sulemana
    Abdul Nashirudeen Mumuni
    Izre-deen Osman Mohammed Abubakari
    Egyptian Journal of Radiology and Nuclear Medicine, 55 (1):
  • [26] THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 313 - 320
  • [27] Estimation of size-specific dose estimate (SSDE) of CT scans using an effective diameter electron density
    Almuqbil, Khuloud
    Abuhaimed, Abdullah
    Abanomy, Ahmed
    Alashban, Yazeed
    Alhawas, Abdulrahman
    Martin, Colin J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [28] Evaluation of a new predictive equation for automated calculation of size-specific dose estimate (SSDE) in CT imaging
    Osman, N. D.
    Abdulkadir, M. K.
    Shuaib, I. L.
    Nasirudin, R. A.
    RADIOGRAPHY, 2024, 30 (01) : 237 - 244
  • [29] Simplifying Size-Specific Radiation Dose Estimates in Pediatric CT
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Vettiyil, Beth
    Lim, Ruth
    Gee, Michael
    Westra, Sjirk
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 167 - 176
  • [30] A size-specific effective dose for patients undergoing CT examinations
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Fujibuchi, T.
    Dougherty, G.
    7TH ASIAN PHYSICS SYMPOSIUM, 2019, 1204