SIZE-specific dose estimate for lower-limb CT

被引:0
|
作者
Masanao Kobayashi
Yusei Nishihara
Tomonobu Haba
Yuta Matsunaga
Yasuki Asada
Shigeki Kobayashi
机构
[1] Fujita Health University,Graduate School of Medical Sciences
[2] Fujita Health University Hospital,Department of Radiology
[3] Nagoya Kyoritsu Hospital,Department of Imaging
关键词
CT; Monte Carlo simulation; Patient dose; Size-specific dose estimate;
D O I
暂无
中图分类号
学科分类号
摘要
The Computed Tomography Dose Index (CTDI) is an indicator for dose management in computed tomography (CT), but has limited use for patient dosimetry. To evaluate the patient dose, the size-specific dose estimate (SSDE), reported by the American Association of Physics in Medicine task groups 204, 220, and 293, must be calculated by the CTDIvol(z) displayed on the CT console, and the conversion factor f(D(z)) from the effective diameter (DEff) or water equivalent diameter (Dw). However, no reports have verified the appropriateness of using the 320-mm diameter phantom for dose assessment in CT examinations involving the lower limbs. Therefore, we validated a new method for evaluating the SSDE(z) of the lower limbs, using two 160-mm diameter phantoms instead of the 320-mm diameter phantom. The CTDIvol(z) obtained from Monte Carlo (MC) simulation study was reliable because they were almost the same as obtained in a dosimetry study. The conversion factor f (D (zl.l.)) for the lower limbs was evaluated based on the CTDIvol(z) obtained by MC simulation performed using two polymethyl methacrylate cylinder phantoms of 160-mm diameter. The MC simulation was performed by the International Commission on Radiological Protection publication 135 reference adult phantom and was used to evaluate the absorbed dose of the pelvis, thighs, knees, and ankles. The dose showing the greatest difference was the thighs, which was 8.3 mGy (16%) lower than the absorbed dose. Thus, the SSDE (zl.l.) could be estimated from the CTDIvol320z\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\mathrm{CTDI}}_{\mathrm{vol}}^{320}\left(\mathrm{z}\right)$$\end{document} displayed on the CT scanner console.
引用
收藏
页码:1183 / 1191
页数:8
相关论文
共 50 条
  • [1] SIZE-specific dose estimate for lower-limb CT
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Asada, Yasuki
    Kobayashi, Shigeki
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (04) : 1183 - 1191
  • [2] Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination
    Tsujiguchi, Takakiyo
    Obara, Hideki
    Ono, Shuichi
    Saito, Yoko
    Kashiwakura, Ikuo
    [J]. JOURNAL OF RADIATION RESEARCH, 2018, 59 (04) : 430 - 435
  • [3] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Karmazyn, Boaz
    Ai, Huisi
    Klahr, Paul
    Ouyang, Fangqian
    Jennings, S. Gregory
    [J]. PEDIATRIC RADIOLOGY, 2016, 46 (09) : 1234 - 1240
  • [4] How accurate is size-specific dose estimate in pediatric body CT examinations?
    Boaz Karmazyn
    Huisi Ai
    Paul Klahr
    Fangqian Ouyang
    S. Gregory Jennings
    [J]. Pediatric Radiology, 2016, 46 : 1234 - 1240
  • [5] THE SIZE-SPECIFIC DOSE ESTIMATE OF PAEDIATRIC HEAD CT EXAMINATIONS FOR VARIOUS PROTOCOLS
    Fahmi, Arif
    Anam, Choirul
    Ali, Mohd Hanafi
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) : 522 - 528
  • [6] Influence of wide beams of CT scans on size-specific dose estimate (SSDE)
    Abuhaimed, A.
    Martin, C. J.
    Demirkaya, O.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S475 - S476
  • [7] Improved Estimates of Trunk and Head CT Radiation Dose: Development of Size-Specific Dose Estimate
    Strauss, Keith J.
    McKenney, Sarah E.
    Brady, Samuel L.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (04) : 560 - 562
  • [8] Dose-Reduced Kidney Stone CT Protocol Optimized with Size-Specific Dose Estimate
    Deng, S.
    Kulkarni, A.
    Harris, N.
    Zimmermann, L.
    Al Helo, R.
    Jordan, D.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E395 - E395
  • [9] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    Larson, David B.
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 : 501 - 505
  • [10] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    David B. Larson
    [J]. Pediatric Radiology, 2014, 44 : 501 - 505