A Comparative Study of Homemade C18 and Commercial C18 Sorbents for Preconcentration of Lead by Minicolumn Solid Phase Extraction

被引:0
|
作者
Heloisa França Maltez
Lúcio Flávio Costa Melo
Sônia Claudia do Nascimento de Queiroz
Isabel Cristina Sales Fontes Jardim
Adilson José Curtius
Eduardo Carasek
机构
[1] Departamento de Química,
[2] Universidade Federal de Santa Catarina,undefined
[3] 88040-900 Florianópolis,undefined
[4] SC,undefined
[5] Brazil,undefined
[6] Departamento de Química Analítica,undefined
[7] Instituto de Química,undefined
[8] Universidade Estadual de Campinas,undefined
[9] C.P. 6154,undefined
[10] 13083-970 Campinas,undefined
[11] SP,undefined
[12] Brazil,undefined
[13] Embrapa Meio Ambiente,undefined
[14] C.P. 69,undefined
[15] 13820-000 Jaguariúna,undefined
[16] SP,undefined
[17] Brazil,undefined
来源
Microchimica Acta | 2004年 / 144卷
关键词
Key words: Flame atomic absorption spectrometry; C18 immobilized on silica; lead.;
D O I
暂无
中图分类号
学科分类号
摘要
A comparative study of commercial C18 chemically immobilized on silica and homemade C18, as sorbents for Pb complexed with O,O-diethyl-dithiophosphate (DDTP) in a flow injection preconcentration system is reported. The homemade C18 sorbent was obtained by sorption of poly(methyloctadecylsiloxane) (PMODS) on the silica support followed by immobilization using thermal treatment. The method follows the concept of green chemistry, since there are no toxic residues after synthesis. The complexed Pb was formed in 1.0 mol L−1 HCl medium and retained on the minicolumn filled with the sorbents. The elution was carried out using ethanol, and the richest 210 µL fraction was collected and analyzed by flame atomic absorption spectrometry. Chemical and flow variables were optimized for each sorbent. The results demonstrated that the performance of the proposed homemade C18 sorbent for preconcentration of Pb complexed with DDTP is very similar to commercial C18 chemically bonded on silica. By processing 25 mL, the enrichment factors were 129 and 125 for commercial C18 and homemade C18, respectively. The limit of detection for commercial and homemade C18 was 0.2 µg L−1 and 0.6 µg L−1, respectively. The relative standard deviation (RSD) was lower than 1.2% for both sorbents for a Pb concentration of 100 µg L−1. The method was also applied successfully to the analysis of water samples, and the accuracy was tested by recovery measurements on spiked samples and biological reference material.
引用
收藏
页码:17 / 21
页数:4
相关论文
共 50 条
  • [41] Research concerning the influence of diet structure on PUFA (C18:2 and C18:3) content in cow milk fat
    Mierlita, D
    Sara, A
    Georgescu, B
    Odagiu, A
    Chereji, I
    Maerescu, C
    Bulletin of the University of Agricultural Sciences and Veterinary Medicine, Vol 60: ANIMAL SCIENCE AND BIOTECHNOLOGY, 2004, 60 : 161 - 164
  • [42] A comparison of performance of various analytical columns in pharmaceutical analysis:: conventional C18 and high throughput C18 Zorbax columns
    Nováková, L
    Solich, P
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1088 (1-2) : 24 - 31
  • [43] Dietary polyunsaturated fatty acids (C18:2 ω6 and C18:3 ω3) do not suppress hepatic lipogenesis
    Sealls, Whitney
    Gonzalez, Monica
    Brosnan, M. Julia
    Black, Paul N.
    DiRusso, Concetta C.
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2008, 1781 (08): : 406 - 414
  • [44] Proportions of C18:In-7 and C18:In-9 fatty acids in canola seedcoat surface and internal lipids
    Hu, X.
    Daun, J.K.
    Scarth, R.
    JAOCS, Journal of the American Oil Chemists' Society, 1994, 71 (02): : 221 - 222
  • [45] Alternation of Fluorescent Spectra of Membrane Markers DiI C18(3) and DiI C18(5) Evoked by Laser Illumination
    Majkowski, Michal
    Poda, Pawel
    Kulbacka, Julita
    Saczko, Jolanta
    Sikorski, Aleksander F.
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2012, 60 (10) : 789 - 791
  • [46] Determination of gabapentin in plasma by liquid chromatography with fluorescence detection after solid-phase extraction with a C18 column
    Gauthier, D
    Gupta, R
    CLINICAL CHEMISTRY, 2002, 48 (12) : 2259 - 2261
  • [47] Extension of the C18 stationary phase knowledge by using the carotenoid test
    Lesellier, Eric
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (19) : 3097 - 3105
  • [48] Stability and selectivity of a cholesterol-coated C18 stationary phase
    Ogden, Phillip B.
    Coym, Jason W.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (23) : 4713 - 4718
  • [49] The gas phase spectrum of cyclic C18 and the diffuse interstellar bands
    Maier, JP
    Boguslavskiy, AE
    Ding, HB
    Walker, GAH
    Bohlender, DA
    ASTROPHYSICAL JOURNAL, 2006, 640 (01): : 369 - 372
  • [50] Preconcentration and dansylation of aliphatic amines using C18 solid-phase packings -: Application to the screening analysis in environmental water samples
    Lloret, SM
    Legua, CM
    Falco, PC
    JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) : 59 - 69