A Comparative Study of Homemade C18 and Commercial C18 Sorbents for Preconcentration of Lead by Minicolumn Solid Phase Extraction

被引:0
|
作者
Heloisa França Maltez
Lúcio Flávio Costa Melo
Sônia Claudia do Nascimento de Queiroz
Isabel Cristina Sales Fontes Jardim
Adilson José Curtius
Eduardo Carasek
机构
[1] Departamento de Química,
[2] Universidade Federal de Santa Catarina,undefined
[3] 88040-900 Florianópolis,undefined
[4] SC,undefined
[5] Brazil,undefined
[6] Departamento de Química Analítica,undefined
[7] Instituto de Química,undefined
[8] Universidade Estadual de Campinas,undefined
[9] C.P. 6154,undefined
[10] 13083-970 Campinas,undefined
[11] SP,undefined
[12] Brazil,undefined
[13] Embrapa Meio Ambiente,undefined
[14] C.P. 69,undefined
[15] 13820-000 Jaguariúna,undefined
[16] SP,undefined
[17] Brazil,undefined
来源
Microchimica Acta | 2004年 / 144卷
关键词
Key words: Flame atomic absorption spectrometry; C18 immobilized on silica; lead.;
D O I
暂无
中图分类号
学科分类号
摘要
A comparative study of commercial C18 chemically immobilized on silica and homemade C18, as sorbents for Pb complexed with O,O-diethyl-dithiophosphate (DDTP) in a flow injection preconcentration system is reported. The homemade C18 sorbent was obtained by sorption of poly(methyloctadecylsiloxane) (PMODS) on the silica support followed by immobilization using thermal treatment. The method follows the concept of green chemistry, since there are no toxic residues after synthesis. The complexed Pb was formed in 1.0 mol L−1 HCl medium and retained on the minicolumn filled with the sorbents. The elution was carried out using ethanol, and the richest 210 µL fraction was collected and analyzed by flame atomic absorption spectrometry. Chemical and flow variables were optimized for each sorbent. The results demonstrated that the performance of the proposed homemade C18 sorbent for preconcentration of Pb complexed with DDTP is very similar to commercial C18 chemically bonded on silica. By processing 25 mL, the enrichment factors were 129 and 125 for commercial C18 and homemade C18, respectively. The limit of detection for commercial and homemade C18 was 0.2 µg L−1 and 0.6 µg L−1, respectively. The relative standard deviation (RSD) was lower than 1.2% for both sorbents for a Pb concentration of 100 µg L−1. The method was also applied successfully to the analysis of water samples, and the accuracy was tested by recovery measurements on spiked samples and biological reference material.
引用
收藏
页码:17 / 21
页数:4
相关论文
共 50 条
  • [1] A comparative study of homemade C18 and commercial C18 sorbents for preconcentration of lead by minicolumn solid phase extraction
    Maltez, HF
    Melo, LFC
    de Queiroz, SCD
    Jardim, ICSF
    Curtius, AJ
    Carasek, E
    MICROCHIMICA ACTA, 2004, 144 (1-3) : 17 - 21
  • [2] Determination of trans fatty acid C18:1, C18:2 and C18:3 isomers in milk fat by silver ion solid phase extraction-gas chromatography
    Li Rui
    Xu Xiaomin
    Li Yali
    Song Guoliang
    Han Jianlong
    Ren Yiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (12) : 1168 - 1172
  • [3] Selective solid phase extraction and preconcentration of ultra trace molybdenum using modified C18 membrane disks
    Ghiasvand, AR
    Mohagheghzadeh, E
    ASIAN JOURNAL OF CHEMISTRY, 2005, 17 (04) : 2143 - 2151
  • [4] C18, C8, and perfluoro reversed phases on diamond for solid-phase extraction
    Saini, Gaurav
    Wiest, Landon A.
    Herbert, David
    Biggs, Katherine N.
    Dadson, Andrew
    Vail, Michael A.
    Linford, Matthew R.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (16) : 3587 - 3593
  • [5] Preparation and evaluation of hydrophilic C18 monolithic sorbents for enhanced polar compound retention in liquid chromatography and solid phase extraction
    Li, Yun
    Xie, Xin
    Lee, Milton L.
    Chen, Jiping
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (48) : 8608 - 8616
  • [6] YMC STATIONARY-PHASE IS NOT A C18
    KIRKLAND, JJ
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1993, 11 (07): : 486 - 486
  • [8] Immobilized imidazolium-based ionic liquids in C18 for solid-phase extraction
    Passos, Marieta L. C.
    Sousa, Emilia
    Saraiva, M. Lucia M. F. S.
    ANALYST, 2020, 145 (07) : 2701 - 2708
  • [9] Preparation of hydrophilic C18 material and its application for solid phase extraction of phenols in water
    Xie Xin
    Li Yun
    Chen Jiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (01) : 49 - 53
  • [10] Genetic variation of C18:1 and C18:2 isomers in sheep milk fat
    Moioli, Bianca
    Contarini, Giovanna
    Pariset, Lorraine
    Marchitelli, Cinzia
    Crisa, Alessandra
    Catillo, Gennaro
    Napolitano, Francesco
    SMALL RUMINANT RESEARCH, 2012, 103 (2-3) : 187 - 193