Detection of bubble nucleation event in superheated drop detector by the pressure sensor

被引:0
|
作者
MALA DAS
NILANJAN BISWAS
机构
[1] Saha Institute of Nuclear Physics,Astroparticle Physics and Cosmology Division
来源
Pramana | 2017年 / 88卷
关键词
Bubble nucleation; pressure sensor; superheated liquid drop.; 07.07.Df; 07.64. ; z; 29.40. ; n;
D O I
暂无
中图分类号
学科分类号
摘要
Superheated drop detector consisting of drops of superheated liquid suspended in polymer or gel matrix is of great demand, mainly because of its insensitivity to ß-particles and ?-rays and also because of the low cost. The bubble nucleation event is detected by measuring the acoustic shock wave released during the nucleation process. The present work demonstrates the detection of bubble nucleation events by using the pressure sensor. The associated circuits for the measurement are described in this article. The detection of events is verified by measuring the events with the acoustic sensor. The measurement was done using drops of various sizes to study the effect of the size of the drop on the pressure recovery time. Probability of detection of events has increased for larger size of the superheated drops and lesser volume of air in contact with the gel matrix. The exponential decay fitting to the pressure sensor signals shows the dead time for pressure recovery of such a drop detector to be a few microseconds.
引用
收藏
相关论文
共 50 条
  • [41] Kinetic characteristic of bubble nucleation in superheated water using fluid inclusions
    Takahashi, M
    Izawa, E
    Etou, J
    Ohtani, T
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2002, 71 (09) : 2174 - 2177
  • [42] BUBBLE NUCLEATION STUDIES .1. FORMATION OF BUBBLE NUCLEI IN SUPERHEATED WATER BY BURSTING BUBBLES
    BERGMAN, T
    MESLER, R
    AICHE JOURNAL, 1981, 27 (05) : 851 - 853
  • [43] SUPERHEATED DROP, BUBBLE, NEUTRON DOSIMETER PERFORMANCE IN A WORK-ENVIRONMENT
    RIEL, G
    RAO, N
    KERSCHNER, H
    NELSON, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 494 - 496
  • [44] Comparison of superheated drop detector with phosphorous pentoxide powder for the detection of neutrons in 18 MV x rays
    Loye, T
    Sidhu, NPS
    Sandison, GA
    MEDICAL PHYSICS, 1999, 26 (05) : 845 - 847
  • [45] Event detection using sensor networks: A case for a hybrid detector
    Michaelides, Michalis P.
    Panayiotou, Christos G.
    PROCEEDINGS OF THE 46TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-14, 2007, : 1660 - 1665
  • [46] Superheated Droplets Detector for Thermal Neutron Detection
    Liu, Yi
    Sullivan, Clair J.
    d'Errico, Francesco
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [47] Neutron-gamma discrimination by pulse analysis with superheated drop detector
    Das, Mala
    Seth, S.
    Saha, S.
    Bhattacharya, S.
    Bhattacharjee, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 196 - 199
  • [48] Pressure drop studies in bubble columns
    Thorat, BN
    Kataria, K
    Kulkarni, AV
    Joshi, JB
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (16) : 3675 - 3688
  • [49] SUPERHEATED-DROP (BUBBLE) NEUTRON DETECTORS AND THEIR COMPLIANCE WITH ICRP-60
    DERRICO, F
    ALBERTS, WG
    RADIATION PROTECTION DOSIMETRY, 1994, 54 (3-4) : 357 - 360
  • [50] SECONDARY BUBBLE NUCLEATION AND BUBBLE ENTRAINMENT VIA THE DROP-FORMED VORTEX RING
    CARROLL, KM
    MESLER, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 207 - COLL