Investigating gait-responsive somatosensory cueing from a wearable device to improve walking in Parkinson’s disease

被引:0
|
作者
Dongli Li
Andre Hallack
Sophie Gwilym
Dongcheng Li
Michele T. Hu
James Cantley
机构
[1] University of Oxford,Department of Physiology, Anatomy and Genetics
[2] Oxfordshire Neurophysiotherapy,Department of Computer Science
[3] The Bosworth Clinic,Oxford Parkinson’s Disease Centre
[4] Quarry Court,Nuffield Department of Clinical Neurosciences, Division of Neurology
[5] University of Texas at Dallas,Division of Systems Medicine, Ninewells Hospital & Medical School
[6] University of Oxford,undefined
[7] University of Oxford,undefined
[8] University of Dundee,undefined
关键词
Parkinson’s disease; Freezing of gait; Cueing; Somatosensory; Wearable; Vibration; Machine learning; Movement; Festination;
D O I
暂无
中图分类号
学科分类号
摘要
Freezing-of-gait (FOG) and impaired walking are common features of Parkinson’s disease (PD). Provision of external stimuli (cueing) can improve gait, however, many cueing methods are simplistic, increase task loading or have limited utility in a real-world setting. Closed-loop (automated) somatosensory cueing systems have the potential to deliver personalised, discrete cues at the appropriate time, without requiring user input. Further development of cue delivery methods and FOG-detection are required to achieve this. In this feasibility study, we aimed to test if FOG-initiated vibration cues applied to the lower-leg via wearable devices can improve gait in PD, and to develop real-time FOG-detection algorithms. 17 participants with Parkinson’s disease and daily FOG were recruited. During 1 h study sessions, participants undertook 4 complex walking circuits, each with a different intervention: continuous rhythmic vibration cueing (CC), responsive cueing (RC; cues initiated by the research team in response to FOG), device worn with no cueing (NC), or no device (ND). Study sessions were grouped into 3 stages/blocks (A-C), separated by a gap of several weeks, enabling improvements to circuit design and the cueing device to be implemented. Video and onboard inertial measurement unit (IMU) data were analyzed for FOG events and gait metrics. RC significantly improved circuit completion times demonstrating improved overall performance across a range of walking activities. Step frequency was significantly enhanced by RC during stages B and C. During stage C, > 10 FOG events were recorded in 45% of participants without cueing (NC), which was significantly reduced by RC. A machine learning framework achieved 83% sensitivity and 80% specificity for FOG detection using IMU data. Together, these data support the feasibility of closed-loop cueing approaches coupling real-time FOG detection with responsive somatosensory lower-leg cueing to improve gait in PD.
引用
收藏
相关论文
共 50 条
  • [21] REAL-TIME FEEDBACK DERIVED FROM WEARABLE SENSORS TO IMPROVE GAIT IN PARKINSON'S DISEASE
    Bartels, Brandon M.
    Moreno, Arianna
    Quezada, Maria Jose
    Sivertson, Haley
    Abbas, James
    Krishnamurthi, Narayanan
    TECHNOLOGY AND INNOVATION, 2018, 20 (1-2) : 37 - 46
  • [22] Characterizing Freezing of Gait Episodes for Parkinson's Disease Using a Wearable Device Quantifying Gait and Posture
    Pallavi, Priya
    Patel, Niravkumar
    Kanetkar, Manasi
    Lahiri, Uttama
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2023, 43 (03) : 266 - 277
  • [23] The use of a multiple cueing device as an adjunct to conventional physiotherapy to improve gait and quality of life in patients with Parkinson's disease - A pilot study
    Tan, D.
    Tan, E. K.
    Sim, E.
    Lim, G.
    Tan, L. W.
    Tan, C.
    MOVEMENT DISORDERS, 2012, 27 : S141 - S141
  • [24] Characterizing Freezing of Gait Episodes for Parkinson’s Disease Using a Wearable Device Quantifying Gait and Posture
    Priya Pallavi
    Niravkumar Patel
    Manasi Kanetkar
    Uttama Lahiri
    Journal of Medical and Biological Engineering, 2023, 43 : 266 - 277
  • [25] A wearable system for visual cueing gait rehabilitation in Parkinson's disease: a randomized non-inferiority trial
    Bartolo, Michelangelo
    Castelli, Alberto
    Calabrese, Marzia
    Buttacchio, Giampiero
    Zucchella, Chiara
    Tamburin, Stefano
    Fontana, Andrea
    Copetti, Massimiliano
    Fasano, Alfonso
    Intiso, Domenico
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2024, 60 (02) : 245 - 256
  • [26] Immediate effects of walking training with Honda Walking Assist Device on gait parameters of Parkinson's disease
    Matsugaki, R.
    Nawata, K.
    Kako, H.
    Shiraishi, J.
    Saeki, S.
    MOVEMENT DISORDERS, 2018, 33 : S400 - S400
  • [27] A protocol for the evaluation of a wearable device for monitoring of symptoms, and cueing for the management of drooling, in people with Parkinson's disease
    Dismore, Lorelle
    Montague, Kyle
    Carvalho, Luis
    Guerreiro, Tiago
    Jackson, Dan
    Guan, Yu
    Walker, Richard
    PLOS ONE, 2023, 18 (02):
  • [28] Treadmill walking as an external pacemaker to improve gait rhythm and stability in Parkinson's disease
    Frenkel-Toledo, S
    Giladi, N
    Peretz, C
    Herman, T
    Gruendlinger, L
    Hausdorff, JM
    MOVEMENT DISORDERS, 2005, 20 (09) : 1109 - 1114
  • [29] Laserlight visual cueing device for freezing of gait in Parkinson's disease: a case study of the biomechanics involved
    Egerton, C. J.
    McCandless, P.
    Evans, B.
    Janssen, J.
    Richards, J. D.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (07) : 518 - 526
  • [30] Treadmill walking as an "external cue" to improve gait rhythm and stability in Parkinson's disease
    Frenkel-Toledo, S
    Giladi, N
    Gruendlinger, L
    Baltadjieva, R
    Hausdorff, JM
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2004, 52 (04) : S217 - S217